background image

242

Upgrade and Maintenance Manual

 RX200 

S8

Optical disk drive

12.3.4 Concluding steps

Ê

"Reassembling" on page 52

Ê

"Connecting the server to the mains" on page 57

Ê

"Switching on the server" on page 58

Ê

"Enabling BitLocker functionality" on page 83

Ê

"Verifying and configuring the backup software solution" on page 75

12.4 Replacing the ODD

12.4.1 Preliminary steps

Ê

"Locating the defective server" on page 43

Ê

"Removing backup and optical disk media" on page 66

Ê

"Disabling BitLocker functionality" on page 63

Ê

"Shutting down the server" on page 46

Ê

"Disconnecting the server from the mains" on page 47

Ê

"Getting access to the component" on page 47

12.4.2 Removing the defective ODD

Ê

Remove the ODD as described in section 

"Removing the ODD" on 

page 240

.

Field Replaceable Unit
(FRU)

Hardware: 10 minutes

Tools:

tool-less

Summary of Contents for PRIMERGY RX200 S8

Page 1: ...Upgrade and Maintenance Manual English PRIMERGY RX200 S8 Server Upgrade and Maintenance Manual February 2014 ...

Page 2: ...pyright and Trademarks Copyright 2014 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes no liability for damages to third party copyrights or other rights ...

Page 3: ...of these components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is used in a hot environment The c...

Page 4: ...l Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain such technology should not be exported from Japan or transferred ...

Page 5: ...8 Upgrade and Maintenance Manual Only for the Japanese market I Although described in this manual some sections do not apply to the Japanese market These options and routines include CSS Customer Self Service ...

Page 6: ... 0 July 2013 Initial release 2 0 October 2013 Added ambient temperature for Cool safe Advanced Thermal Design updated Performing a RAID array rebuild updated Equipping the PCIe slots added figure Routing the front LAN cable 3 0 February 2014 Energy Star removed software procedures updated ...

Page 7: ...tion 31 3 1 Safety instructions 31 3 2 CE conformity 39 3 3 FCC Class A Compliance Statement 39 3 4 Environmental protection 40 4 Basic hardware procedures 43 4 1 Using diagnostics information 43 4 1 1 Locating the defective server 43 4 1 2 Determining the error class 44 4 1 2 1 Global Error indicator 44 4 1 2 2 Customer Self Service CSS indicator 44 4 1 3 Locating the defective component 45 4 1 3...

Page 8: ...g functionality 64 5 1 2 1 Viewing boot watchdog settings 64 5 1 2 2 Configuring boot watchdog settings 65 5 1 3 Removing backup and optical disk media 66 5 1 4 Verifying and configuring the backup software solution 66 5 1 5 Note on server maintenance in a Multipath I O environment 67 5 1 6 Switching on the ID indicator 69 5 2 Completing the maintenance task 70 5 2 1 Updating or recovering the sys...

Page 9: ...g 88 5 2 17 1 After replacing upgrading LAN controllers 88 5 2 17 2 After replacing the system board 88 5 2 18 Switching off the ID indicator 89 5 2 19 Performing a fan test after replacing a defective fan 89 6 Power supply 91 6 1 Basic information 92 6 2 Installing a power supply unit 93 6 2 1 Preliminary steps 93 6 2 2 Removing the dummy cover 93 6 2 3 Installing the power supply unit 94 6 2 4 C...

Page 10: ...teps 113 7 3 2 Removing the 2 5 inch HDD SSD module 114 7 3 3 Installing the 2 5 inch dummy module 115 7 3 4 Concluding steps 115 7 4 Replacing a 2 5 inch HDD SSD module 115 7 4 1 Preliminary steps 116 7 4 2 Removing the defective 2 5 inch HDD SSD module 116 7 4 3 Installing the new 2 5 inch HDD SSD module 116 7 4 4 Concluding steps 116 7 5 Replacing the 4xHDD backplane 117 7 5 1 Preliminary steps...

Page 11: ... modules 146 9 3 1 Installing SFP transceiver modules 146 9 3 2 Removing an SFP transceiver module 149 9 4 Expansion cards and riser cards 152 9 4 1 Installing an expansion card slot 1 3 152 9 4 1 1 Preliminary steps 152 9 4 1 2 Removing the slot cover slot 1 3 153 9 4 1 3 Installing the expansion card slot 1 3 154 9 4 1 4 Concluding steps 156 9 4 2 Installing an expansion card slot 4 157 9 4 2 1 ...

Page 12: ...BU 172 9 5 1 Basic information 172 9 5 2 Installing a BBU 172 9 5 2 1 Preliminary steps 172 9 5 2 2 Connecting the BBU cable to the BBU 172 9 5 2 3 Installing the BBU in the holder 173 9 5 2 4 Installing the BBU with the holder 174 9 5 2 5 Concluding steps 176 9 5 3 Installing an FBU 177 9 5 3 1 Preliminary steps 177 9 5 3 2 Installing TFM to the RAID controller if applicable 178 9 5 3 3 Installin...

Page 13: ...Main memory 195 10 1 Basic information 196 10 1 1 Memory sequence 198 10 1 1 1 Population rules 198 10 1 1 2 Independant Channel mode 199 10 1 1 3 Mirrored Channel and Performance modes 200 10 1 1 4 Rank Sparing mode 201 10 2 Installing a memory module 205 10 2 1 Preliminary steps 205 10 2 2 Selecting the memory slot 205 10 2 3 Installing a memory module 206 10 2 4 Concluding steps 206 10 3 Removi...

Page 14: ...Removing the defective processor 224 11 3 4 Installing the new processor 227 11 3 5 Applying the thermal paste to the processor surface 229 11 3 6 Installing the heat sink 231 11 3 7 Concluding steps 232 11 4 Replacing a heat sink 232 11 4 1 Preliminary steps 232 11 4 2 Removing the defective heat sink 232 11 4 3 Installing the new heat sink 233 11 4 4 Concluding steps 233 12 Optical disk drive 23...

Page 15: ...management LAN connector 253 13 3 Removing the front VGA and or front LAN 254 13 3 1 Preliminary steps 254 13 3 2 Disconnecting the front LAN cable 254 13 3 3 Disconnecting the front VGA cable 255 13 3 4 Removing the front VGA LAN module 256 13 3 5 Removing the front connectors 256 13 3 6 Installing the front VGA LAN module 259 13 3 7 Concluding steps 259 13 4 Replacing the front VGA and or front ...

Page 16: ...76 14 3 3 Installing the slot cover 277 14 3 4 Concluding steps 277 14 4 Replacing the serial interface 278 14 4 1 Preliminary steps 278 14 4 2 Removing the defective serial interface 278 14 4 3 Installing the new serial interface 278 14 4 4 Concluding steps 278 15 System board and components 279 15 1 Basic information 279 15 2 Replacing the CMOS battery 280 15 2 1 Preliminary steps 280 15 2 2 Rep...

Page 17: ...eliminary steps 297 15 4 3 2 Removing the defective TPM 298 15 4 3 3 Installing the new TPM 298 15 4 3 4 Concluding steps 298 15 5 Onboard SAS enabling key 299 15 5 1 Installing the onboard SAS enabling key 299 15 5 1 1 Preliminary steps 299 15 5 1 2 Installing the onboard SAS enabling key 299 15 5 1 3 Concluding steps 300 15 5 2 Removing the onboard SAS enabling key 301 15 5 2 1 Preliminary steps...

Page 18: ...erver interior 323 17 2 Connectors and indicators 325 17 2 1 Connectors and indicators on the system board 325 17 2 1 1 Onboard connectors 325 17 2 1 2 Onboard indicators and controls 327 17 2 1 3 I O panel connectors 329 17 2 1 4 I O panel indicators 330 17 2 1 5 Indicators on power supply units 331 17 2 2 Indicators on the front panel 332 17 3 Onboard settings 334 17 4 Minimum startup configurat...

Page 19: ...ing defective hardware components This manual focuses on on site maintenance tasks It is recommended to prepare each service assignment following remote diagnostics procedures as described in the ServerView Suite Local Service Concept LSC manual see section Documents you need at hand on page 28 V CAUTION The document at hand comprises procedures of a wide range of complexity Check the profile of q...

Page 20: ...at are being emphasized Ê describes activities that must be performed in the order shown Abc indicates keys on the keyboard V CAUTION Pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data I indicates additional information notes and tips indicates the procedure category in terms of complexity ...

Page 21: ...ed Thermal Design option only components that support the higher operating range may be installed Further information on this is available in the configurator Installing optional components The PRIMERGY RX200 S8 Server Operating manual gives an introduction to server features and provides an overview of available hardware options Use the Fujitsu ServerView Suite management software and the iRMC we...

Page 22: ...rols and indicators of your server refer to the operating manual of your server and section Connectors and indicators on page 325 If the system has been powered off in order to replace a non hot plug unit a system of PRIMERGY diagnostic indicators guides you to the defective component The Indicate CSS button enables the indicator next to the defective component even if the server has been switched...

Page 23: ...ble Units CRU Customer Replaceable Units are intended for customer self service and may be installed or replaced as hot plug components during operation I Components that the customer is entitled to replace may differ according to the service form in his country Hot plug components increase system availability and guarantee a high degree of data integrity and fail safe performance Procedures can b...

Page 24: ...board will report defective Upgrade and Repair Units as customer replaceable CSS components Upgrade and repair procedures involve shutting down and opening the server V CAUTION The device may be seriously damaged or cause damage if it is opened without authorization or if repairs are attempted by unauthorized and untrained personnel Components that are handled as Upgrade Units Processors upgrade k...

Page 25: ...ld Replaceable Units must be performed exclusively by Fujitsu service personnel or technicians trained by Fujitsu Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability Components that are handled as Field Replaceable Units Processor replacement SAS SATA backplanes Power distribution board Front panel module Management and d...

Page 26: ...e described in section Starting the maintenance task on page 63 Rack removal disassembly yes making the server available removing the server from the rack if applicable Transport no Transporting the server to the service table where required depends on local customer conditions Maintenance procedures yes maintenance procedures including preliminary and concluding software tasks Transport no Return...

Page 27: ...ginning of each procedure Screw driver bit insert Screw Usage Type Phillips PH2 No 2 Chassis M3 x 4 5 mm silver C26192 Y10 C67 Phillips PH2 No 2 System board M3 x 6 mm silver C26192 Y10 C68 Special bit insert TPM screw REM 3 x 15 mm black C26192 Y10 C176 Phillips PH1 No 1 UFM nylon screw M3 x 4 5 mm white A3C40109082 Phillips PH1 No 1 TFM module M2 5 x 4 mm silver C26192 Y10 C103 Table 2 List of u...

Page 28: ...let Quick installation poster for initial operation available online ServerView Quick Start Guide ServerView クイックスタートガ イド for the Japanese market Information on initial server setup and software configuration available online Safety notes and regulations manual 安全上のご注意 for the Japanese market Important safety information available online or as a printed copy PRIMERGY RX200 S8 Server Operating Manu...

Page 29: ...ng used devices manual Recycling and contact information available online or as a printed copy Service Desk leaflet サポート サービス for the Japanese market Additional documentation RAID documentation available online at http manuals ts fujitsu com under Industry standard servers Expansion Cards Storage Adapters e g Integrated RAID for SAS User Guide LSI MegaRAID SAS Software User Guide Modular RAID Cont...

Page 30: ...30 Upgrade and Maintenance Manual RX200 S8 Before you start ...

Page 31: ...r customer service team The actions described in this manual shall be performed by technical specialists A technical specialist is a person who is trained to install the server including hardware and software Repairs to the device that do not relate to CSS failures shall be performed by service personnel Please note that unauthorized interference with the system will void the warranty and exempt t...

Page 32: ...ture can increase to 40 C If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector the power supply s fuse protection must comply with the requirements for non industrial power supply networks for type A connectors The unit automatically adjusts itself to a mains voltage in a range of 100 V 240 V Ensure that the local mains vo...

Page 33: ...circuit In emergencies e g damaged casing controls or cables penetration of liquids or foreign bodies contact the system administrator or your customer service team Only disconnect the system from the mains power supply if there is no risk of harming yourself Proper operation of the system in accordance with IEC 60950 1 resp EN 60950 1 is only ensured if the casing is completely assembled and the ...

Page 34: ...electricity To ensure reliable protection if you are wearing an earthing band on your wrist when working with this type of module connect it to an unpainted non conducting metal part of the system Do not touch the circuitry on boards or soldered parts Hold the metallic areas or the edges of the circuit boards Install the screw removed during installation detaching internal options in former device...

Page 35: ...ional labels applied may change the mechanical properties of a CD DVD BD and cause imbalance Damaged and imbalanced CDs DVDs BDs can break at high drive speeds data loss Under certain circumstances sharp CD DVD BD fragments can pierce the cover of the optical drive equipment damage and can fly out of the device danger of injury particularly to uncovered body parts such as the face or neck High hum...

Page 36: ...ot attach stickers or similar to the label side Doing so may cause rotational eccentricity and abnormal vibrations When a CD DVD BD is moved from a cold place to a warm place moisture condensation on the CD DVD BD surface can cause data read errors In this case wipe the CD DVD BD with a soft dry cloth then let it air dry Do not dry the CD DVD BD using devices such as a hair dryer To avoid dust dam...

Page 37: ...f the system and remove the power plugs from the power outlets before installing or removing components with ESDs You must always discharge static build up e g by touching a grounded object before working with such components Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chassis of the system unit Always ho...

Page 38: ...panel When connecting and disconnecting cables observe the relevant instructions in the Important Information chapter of the technical manual for the corresponding rack The technical manual is supplied with the corresponding rack When installing the rack make sure that the anti tilt protection is correctly fitted For safety reasons no more than one unit may be removed from the rack at any one time...

Page 39: ... used in strict accordance with the instructions may cause harmful interference to radio communications However there is no warranty that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by o...

Page 40: ...ndly product design and development This product has been designed in accordance with the Fujitsu standard for environmentally friendly product design and development This means that key factors such as durability selection and labeling of materials emissions packaging ease of dismantling and recycling have been taken into account This saves resources and thus reduces the harm done to the environm...

Page 41: ...arts wherever possible since this makes it difficult to recycle them Returns recycling and disposal Please handle returns recycling and disposal in accordance with local regulations Details regarding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu...

Page 42: ...42 Upgrade and Maintenance Manual RX200 S8 Important information ...

Page 43: ...on Illustrated Spares catalogs are available online at http manuals ts fujitsu com illustrated_spares EMEA market only Perform the following diagnostics procedures to identify defective servers and components 4 1 1 Locating the defective server When working in a datacenter environment switch on the ID indicator on the front and rear connector panels of the server for easy identification Ê Press th...

Page 44: ...ispatched to replace the part I The indicators also light up in standby mode and after a server restart due to a power failure 4 1 2 1 Global Error indicator Ê Check the Global Error indicator on the front or connector panel of the server Ê For further diagnostics proceed as follows Hardware errors Check the System Event Log SEL as described in section Viewing the SEL on page 81 Software agent rel...

Page 45: ...e if the defective component is a customer or field replaceable unit see section Determining the error class on page 44 4 1 3 2 Local diagnostic indicators on the system board Using the Indicate CSS button Ê Shut down and power off the server Ê Disconnect the AC power cord s from the system I It is mandatory to disconnect power cords in order to use the Indicate CSS functionality Ê Press the Indic...

Page 46: ...m administrator that the server will be shut down and put offline Ê Terminate all applications Ê Perform the required procedures described in the preliminary steps of each upgrade or maintenance task Ê Shut down the server I If the system is running an ACPI compliant operating system the pressing the On Off button will performs a graceful shutdown Ê Switch on the ID indicator on the front and rear...

Page 47: ...from the cable clamps 4 4 Getting access to the component V CAUTION Before removing or installing covers turn off the server and all peripheral devices Also unplug all power cables from the outlet Failure to do so can cause electric shock In order to comply with applicable EMC regulations regulations on electromagnetic compatibility and satisfy cooling requirements the server must not run while th...

Page 48: ...For further safety information please refer to chapter Important information on page 31 Ê Remove all remaining external cables from the rear connector panel and expansion cards Ê If you are not using a cable mounting arm CMA kit ensure that the rear cables are long enough not to be strained or damaged when extending the server out of the rack Figure 3 Extending the server out of the rack Ê Fold do...

Page 49: ...k cabinet For the Japanese market please refer to 安全上のご注意 Additionally a lifter is required in the following cases The server weighs more than 50 kg The server weighs more than 21 kg and is installed above the height of 25 U When using a lifter this removal procedure needs to be carried out by maintenance personnel For configurations below 32 kg At least two people are needed to lift the server ou...

Page 50: ...nce Manual RX200 S8 Basic hardware procedures Figure 4 Removing the server from the rack Ê Release the locking bars on both telescopic rails 1 Ê Lift the server out of the telescopic rails 2 and place it on an even surface 0 ...

Page 51: ...ng the housing cover Figure 5 Removing the fan cover Ê Push the two green buttons 1 in the direction of the arrow Ê Lift the fan cover upward and remove it 2 4 4 4 Removing the housing cover Figure 6 Removing the housing cover Ê Push the housing cover as far as it will go in the direction of the arrow 1 Ê Lift off the housing cover upward 2 ...

Page 52: ...bility and satisfy cooling requirements the server must not run while the top side cover is removed For further safety information please refer to chapter Important information on page 31 4 5 1 Installing the housing cover Figure 7 Installing the housing cover Ê Position the housing cover so that it protrudes somewhat over the rear edge 1 Make sure that each bolt is positioned in the corresponding...

Page 53: ...he fan cover in a slight angle Figure 9 Installing the fan cover Ê Push the fan cover down 1 Ê Push the edges of the fan cover down until the two green buttons engage 2 I For a correct sliding the server into the rack the height of the fan cover and the chassis top must be on the same level If the fan cover is higher push it down again until the level is equal ...

Page 54: ...ghs more than 50 kg The server weighs more than 21 kg and is to be installed above the height of 25 U When using a lifter this installation procedure needs to be carried out by maintenance personnel For configurations below 32 kg At least two people are needed to lift the server into the rack cabinet For configurations below 55 kg At least three people are needed to lift the server into the rack c...

Page 55: ...The telescopic rails must click into place so that they can no longer be moved Ê At a slight angle lower the server onto the rear mounting point on the telescopic rails 2 Ê Fold down the server while pressing the rail to the server side 3 Ensure that all six rack mounting bolts are properly seated in the mounting points on the telescopic rails and that the locking bars engage 4 0 1 2 ...

Page 56: ...f the fan cover is higher push it down again until the level is equal Ê Release the locking mechanism of both rails 1 Ê Push the server as far as it will go into the rack 2 until the quick release levers engage 3 V CAUTION Be careful with your fingers You can pinch them when the quick release levers change to the release position Ê Reconnect all cables except the power cord to the server rear 0 1 ...

Page 57: ...nected to a different AC power source from the other power supply unit If one AC power source should fail the server will still continue to run I After connecting the server to the mains it takes about 60 secondes until the server enters the standby mode Ê Ensure that the indicator on the power supply unit lights up green I For more information see section Indicators on power supply units on page ...

Page 58: ... wait at least 60 seconds before pressing the On Off button For further safety information please refer to chapter Important information on page 31 I This step is only applicable to replace or expand non hot plug components Ê Press the On Off button to start up the server Ê Ensure that the power on indicator above the On Off button is lit green Ê Perform the required procedures described in the co...

Page 59: ... riser module 1 Figure 14 Installing the riser module 1 Ê Insert the riser card into the system board slot Ê Press down the riser card module 1 using the green touch points Removing the riser module 2 Figure 15 Removing the riser module 2 Ê Carefully pull out the riser module 2 upward ...

Page 60: ...ling the riser module 2 Ê Insert the two riser cards into the system board slots Ê Press down the riser card module 2 using the green touch points Ê If necessary connect the cables to the other components Removing the riser module 3 Figure 17 Removing the riser module 3 Ê Carefully pull out the riser module 3 upward ...

Page 61: ...alling the riser module 3 Figure 18 Installing the riser module 3 Ê Insert the riser card into the system board slot and the two recesses see close up Ê Press down the riser card module 3 using the green touch points Ê If necessary connect the cables to the other components ...

Page 62: ...s 4 9 Handling the air duct Removing the air duct Figure 19 Removing the air duct Ê Carefully pull out the air duct upward Installing the air duct Figure 20 Installing the air duct Ê Install the air duct Notice the hooks see close ups and the guidings see orange lines ...

Page 63: ...e V CAUTION With BitLocker features enabled modifying the system configuration hardware or firmware settings may render the system inaccessible The system may enter Recovery Mode and require a 48 digits recovery password to return to normal operation Ensure to disable BitLocker drive encryption before maintaining the server When disabled BitLocker uses a plain text key instead of the Trusted Platf...

Page 64: ...e If the watchdog timer expires the system will automatically reboot 5 1 2 1 Viewing boot watchdog settings Viewing boot watchdog settings in the BIOS Ê Enter the BIOS Ê Select the Server Mgmt menu Ê Under Boot Watchdog you can obtain detailed information about the current watchdog status time out intervals and actions that are triggered if watchdog time outs are exceeded I For detailed informatio...

Page 65: ... disabled before starting maintenance task Otherwise the Boot watchdog might initiate a system reboot before the flash process is complete V CAUTION An incomplete firmware upgrade process may render the server inaccessible or result in damaged destroyed hardware Timer settings can be configured in the BIOS or using the ServerView iRMC web frontend Configuring boot watchdog settings in the BIOS Ê E...

Page 66: ...cts guide available to Fujitsu service partners from the following https address https partners ts fujitsu com com service ps Servers PRIMERGY Pages TapeFacts aspx For the Japanese market please contact Fujitsu support if forcible tape ejection is necessary I Fujitsu does not assume responsibility for any damage to the tape drive the data cartridge tape or for the loss of any data resulting from m...

Page 67: ...ss Ê If performing an offline BIOS firmware update first of all prepare the ServerView Update DVD or USB stick Ê Download the latest ServerView Update DVD image from Fujitsu for the EMEA market ftp ftp ts fujitsu com images serverview for the Japanese market http jp fujitsu com platform server primergy products note svsdvd dvd Ê Burn the image to a DVD Ê In order to create a bootable USB stick ple...

Page 68: ...s Ê Once the server has been started press F12 to enter the boot menu Ê Use the Ê and Ë cursor keys to select your DVD drive or USB stick as boot device and press ENTER The server will now boot from the Update DVD or USB stick Ê After the boot process is complete select your preferred GUI language The Update Manager Express main window will be displayed Ê Finish the intended maintenance task I For...

Page 69: ...anguage Ê In the initial Installation Manager startup window choose PrimeCollect from the Installation Manager mode section Ê Click Continue to proceed Ê Finish the intended maintenance task I For further information refer to the PrimeCollect user guide Concluding the procedure Ê After the update or diagnostic procedure has been completed shut down the server reconnect all external I O connections...

Page 70: ... 2 Completing the maintenance task 5 2 1 Updating or recovering the system board BIOS and iRMC After replacing the system board memory or a CPU it is essential to upgrade the BIOS and iRMC to the latest version The latest BIOS and iRMC versions are available from the Fujitsu support internet pages at http ts fujitsu com support EMEA market http jp fujitsu com platform server primergy downloads Jap...

Page 71: ...rily Ê Restart the server Ê The system will detect the USB stick I If the BIOS cannot identify the USB stick the pop up message Failed to boot for Emergency flash Please Reset now will show up in the center of the screen Ê Choose one of the following options from the update tool menu to start the iRMC update process Normal Choose this option to update an existing system board Initial Choose this o...

Page 72: ... necessary Ê Ensure that the Global Error indicator and the ID indicator are flashing to indicate that the server is entering the iRMC recovery state Ê Press the Power On Off button The system starts the POST process I In iRMC recovery mode the FUJITSU logo does not show up Ê The system will detect the USB stick I If the BIOS cannot identify the USB stick the pop up message Failed to boot for Emer...

Page 73: ...a on the Chassis ID EPROM has been restored to the system board Chassis IDPROM Restore successful After replacing the Chassis ID EPROM I In case of the PRIMERGY RX200 S8 server the Chassis ID EPROM is integrated on the front panel board Ê Check the SEL log files as described in section Viewing and clearing the System Event Log SEL on page 81 to verify whether a backup copy of the system board sett...

Page 74: ...ct Product drop down lists choose your PRIMERGY server or enter its serial or ident number into the search field Ê Select your operating system and version Ê Select the desired component type e g SAS RAID Ê Select your controller from the device list to expand a compilation of available drivers and firmware Ê Select the desired file and click Download for further instructions 5 2 4 Enabling Option...

Page 75: ...r the expansion card s firmware Ê Press the displayed key combination Ê Modify the expansion card firmware options as desired Ê Save your changes and exit the firmware I The expansion card s option ROM can now be disabled in the system board BIOS Exception If the expansion card controls a permanent boot device the card s Option ROM has to remain enabled 5 2 5 Verifying and configuring the backup s...

Page 76: ...n suitable backup software solutions and related documentation is available to Fujitsu service partners from the Fujitsu Extranet pages 5 2 6 Resetting the boot retry counter The boot retry counter is decremented from its preset value every time the POST watchdog initiates a system reboot When the value has reached 0 the system will shut down and power off 5 2 6 1 Viewing the boot retry counter Th...

Page 77: ...enu Ê Under Boot Retry Counter press the or keys to specify the maximum number of boot attempts 0 to 7 Ê Exit the BIOS Resetting the boot retry counter using the ServerView Operations Manager Ê In the ServerView Operations Manager Administration view select Server Configuration Ê If more than one server is managed in SVOM select the target server and click Next Ê From the Server Configuration menu...

Page 78: ...k Timer settings can be configured in the BIOS or using the ServerView iRMC web frontend Configuring boot watchdog settings in the BIOS Ê Enter the BIOS Ê Select the Server Mgmt menu Ê Under Boot Watchdog set the Action setting to Reset Ê Save your changes and exit the BIOS I For detailed information on how to access the BIOS and modify settings refer to the corresponding BIOS Setup Utility refere...

Page 79: ...s Ê Reset replaced components to Enable Ê Save your changes and exit the BIOS I For detailed information on how to access the BIOS and modify settings refer to the corresponding BIOS Setup Utility reference manual 5 2 9 Verifying the memory mode If a memory module fails the server will reboot and the defective module will be disabled As a result the current operation mode e g Mirrored Channel mode...

Page 80: ...rsal Time Coordinated in the operating system the BMC local time may not be mapped correctly Ê After replacing the system board ask the system administrator whether the RTC or UTC time standard is to be used as system time I If the system time RTC is set to UTC the SEL System Event Log time stamps may differ from the local time Ê Enter the BIOS Ê Select the Main menu Ê Under System Time and System...

Page 81: ...ves you an overview of the monitored components as well as the associated events contained in the system event log on the managed server Under Monitored Components the monitored components are listed If a component has the status Warning or Error you can select it in the list and click Acknowledge This confirms the event on the server side You may have to log on to the server beforehand The status...

Page 82: ...e NIC configuration file in a Linux environment In order to prevent errors caused by changing network device names eth x it is recommended to store the MAC address hardware address of a network interface card in the related NIC configuration file of the Linux OS When replacing a network controller or the system board with onboard LAN controllers in a server running Linux OS the MAC address will ch...

Page 83: ... for network controller 1 enter the following command vi etc sysconfig network scripts ifcfg eth1 In vi specify the new MAC address as follows HWADDR xx xx xx xx xx xx Ê Save and close the definition file Ê For the changes to take effect you need to reboot the network by entering the following command service network restart I If the system board or network controller offers multiple LAN ports it ...

Page 84: ...cking Security and then clicking Bitlocker Drive Encryption I Administrator permission required If you are prompted for an administrator password or confirmation type the password or provide confirmation Ê To enable a temporarily disabled BitLocker click Turn On BitLocker Ê Follow the instructions in the BitLocker Setup wizard I For further information on how to enable BitLocker drive encryption p...

Page 85: ...roller the MAC Media Access Control and WWN World Wide Name addresses will change I In addition to the procedures described below MAC WWN addresses can also be found on the type label attached to a network controller or system board 5 2 15 1 Looking up MAC addresses Ê Enter the ServerView iRMC web frontend Ê Select the System Information menu Ê Under Network Inventory you will find detailed inform...

Page 86: ...orm the customer about the changed WWN address QLogic FC adapters Ê Enable the network controller s Option ROM in the system board BIOS as described in section Enabling Option ROM scan on page 74 Ê Restart the server Ê During boot as soon as the QLogic BIOS utility option appears press ALT Q or CTRL Q Ê Under Select Host Adapter use the arrow keys æ Ë to select the desired FC FCoE adapter and pres...

Page 87: ...com service ps Servers PRIMERGY Ê Select your PRIMERGY system from the main area of the page Ê From the categories selection choose Software Tools Documentation Ê In the Tools area click Tools Chassis IDProm Tool to download the file tool chassis Idprom Tool zip I For the Japanese market follow the instructions provided separately Note on Cool safe Advanced Thermal Design ATD I If the Cool safe Ad...

Page 88: ...user guide 5 2 17 1 After replacing upgrading LAN controllers Please note when re using a replaced LAN controller Ê Confirm with the customer whether the LAN controller you have replaced has been used as part of a LAN teaming configuration Ê If LAN teaming has been active you will need to restore the configuration using the LAN driver utility after replacing the LAN controller Ensure that the cont...

Page 89: ... Overview click Identify LED Off to switch off the ID indicators Using ServerView Operations Manager Ê In ServerView Operations Manager Single System View and press the Locate button in the title bar to switch off the ID indicator 5 2 19 Performing a fan test after replacing a defective fan After replacing a defective system fan or power supply unit containing a defective fan the fan error indicat...

Page 90: ...ly Fan Test set the daily fan test time to a few minutes from the current time Ensure to note down your previous setting Ê Click Save Page The fan test will be started at the specified time Ê After the fan test is complete restore the time setting to its initial value and click Save Page I For more detailed information refer to the ServerView Operations Manager user guide For the Japanese market E...

Page 91: ...wer supply unit When installing the power supply unit be sure to confirm that the connector of the power supply unit is not damaged or bent Do not insert your hands in the power supply unit slot when removing the power supply unit Doing so may cause electric shock If the power supply unit is hard to remove do not pull out it by force The power supply unit is heavy so handle it carefully If you dro...

Page 92: ... V As an option the power supply can be expanded with an extra power supply unit to create a redundant power supply If a power supply unit fails the redundant configuration assures continued operation The defective power supply unit can be replaced during operation hot plug There are two types of power supply units available 450W power supply unit 800W power supply unit Both power supply units mus...

Page 93: ...rips together as indicated by the arrows 1 and remove the dummy cover 2 V CAUTION Keep the dummy cover for future use If the power supply unit is removed and not replaced with a new one the dummy cover must be reinstalled due to cooling to comply with applicable EMC regulations regulations on electromagnetic compatibility and to protect against fire Customer Replaceable Unit CRU Hardware 5 minutes...

Page 94: ...igure 25 Installing the power supply unit Ê Carefully push the power supply unit into the empty bay 1 until it stops Ê Push the handle of the power supply unit as far as it will go in the direction of the arrow 2 I Make sure that the power supply unit engages correctly in the bay and is locked in position This is the only way to prevent the power supply unit from sliding out of its bay and being d...

Page 95: ... and Maintenance Manual 95 Power supply Figure 26 Installing the cable clamp Ê Push the cable clamp into the corresponding hole until it clicks in 6 2 4 Concluding steps Ê Connecting the server to the mains on page 57 ...

Page 96: ... Cable Management Arm Regarding of removing power supply units additional tasks are needed due to an interference between CMA stopper and the power supply units Figure 27 Unlocking the CMA stopper Ê Push the lock spring inward to unlock the CMA stopper Customer Replaceable Unit CRU Hardware 5 minutes Tools tool less ...

Page 97: ...opper with the mounted crossbar Ê Hold the CMA stopper the crossbar and the CMA including cables in the right hand Figure 29 Removing the power supply unit Ê Remove the power supply unit and install the dummy cover carefully Ê Mount the complete assembly CMA stopper the crossbar and the CMA again into the rail ...

Page 98: ...p the power cord for future use Figure 30 Unlocking and removing the power supply unit Ê Push the handle of the power supply unit halfway upward in the direction of the arrow 1 Ê Push the lock in direction of the arrow 2 Ê Grip the handle and pull out the power supply unit in the direction of the arrow 3 V CAUTION Never leave the bay for the power supply unit empty for more than two minutes during...

Page 99: ...clicks into place Ensure that the marking TOP is right and the upper rear cant of the dummy cover fits under the PSU cage 6 3 4 Concluding steps No steps needed 6 4 Replacing a power supply unit V CAUTION When replacing a power supply unit in a non redundant PSU configuration the server must be switched off first Customer Replaceable Unit CRU Hardware 5 minutes Tools tool less ...

Page 100: ...he power supply unit see figure 29 and install the new power supply unit carefully Ê Mount the complete assembly CMA stopper the crossbar and the CMA arm again into the rail 6 4 1 Preliminary steps Ê Locating the defective server on page 43 Ê Check which power supply unit is defective A power supply unit is defective when the indicator on the power supply unit lights up orange see section Indicato...

Page 101: ...configuration Switching on the server on page 58 Ê Performing a fan test after replacing a defective fan on page 89 6 5 Replacing the power distribution board 6 5 1 Preliminary steps Ê Locating the defective server on page 43 Ê Disabling BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on...

Page 102: ...ard Ê Remove the power supply units as described in section Removing a power supply unit on page 98 Figure 32 Disconnecting the power cables Ê Disconnect the two power cables from the connector PWR 1 1 and connector PWR 2 2 of the system board Figure 33 Removing the screws Ê Remove the two screws see circles ...

Page 103: ...Power supply Figure 34 Removing the power distribution board Ê Pull the power distribution board in direction of the arrow 1 Ê Remove the power distribution board upward 2 6 5 3 Installing the new power distribution board Figure 35 Position bolts ...

Page 104: ...distribution board Ê Position the power distribution board on the two bolts see circles in figure 35 1 Ê Push the power distribution board in the direction of the arrow 2 Figure 37 Fastening the power distribution board Ê Fasten the power distribution board with the two screws see circles ...

Page 105: ...m board Ê Install all power supply units you removed beforehand as described in section Installing the power supply unit on page 94 6 5 4 Concluding steps Perform the following procedures Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Enabling BitLocker functionality on page 83 ...

Page 106: ...106 Upgrade and Maintenance Manual RX200 S8 Power supply ...

Page 107: ...rcuit boards Before removing the unit wait for about 30 seconds until the disk stops spinning completely When a hard disk drive is starting up a resonant noise may be audible for a short while This does not indicate a failure Depending on the OS you can configure the write cache settings for the hard disk drives If a power failure should occur while the write cache is enabled cached data may be lo...

Page 108: ...he following configurations configuration with up to four HDD SSD modules and optional ODD configuration with up to eight HDD SSD modules Each HDD SSD module can accommodate a SAS SATA hard disk drive or SATA solid state drive with a 2 5 inch format The HDD SSD modules are connected to the HDD backplane wirelessly This allows HDD SSD modules to be plugged in or pulled out easily If the server has ...

Page 109: ...The HDD SSD numbering as listed in the ServerView RAID Manager differs from the HDD SSD mounting order 7 1 3 Configuration with up to eight HDD SSD modules Figure 40 Equipping the eight HDD SSD bays Controller Channel Connection SAS controller in slot 4 1 Drives 1 2 3 4 2 5 inch HDDs SSDs Bay RAID Manager Channel log Drive Bay RAID Manager Channel log Drive 1 0 1 0 2 1 1 1 3 2 1 2 4 3 1 3 Table 4 ...

Page 110: ...order 7 2 Installing a 2 5 inch HDD SSD module 7 2 1 Preliminary steps No steps needed Controller Channel Connection SAS controller in slot 4 1 Drives 1 2 3 4 2 Drives 5 6 7 8 2 5 inch HDDs SSDs Bay RAID Manager Channel log Drive Bay RAID Manager Channel log Drive 1 0 1 0 2 1 1 1 3 2 1 2 4 3 1 3 5 4 2 4 6 5 2 5 7 6 2 6 8 7 2 7 Table 5 HDD naming scheme Customer Replaceable Unit CRU Hardware 5 minu...

Page 111: ...module Ê Press both tabs on the dummy module together until the locking mechanism disengages 1 Ê Pull the dummy module out of the bay 2 V CAUTION Store the dummy module in a safe place If you have removed an HDD SSD module and do not install a new one in its place put the dummy module back in its place for cooling to comply with EMC regulations regulations regarding electromagnetic compatibility a...

Page 112: ...m as follows 1 Press the two green tabs of the locking lever together 1 2 Push the handle of the HDD SSD module fully in the direction of the arrow 2 The HDD SSD module is now unlocked Figure 43 Installing the 2 5 inch HDD SSD module Ê Carefully push the HDD SSD module into the empty bay 1 until it stops Ê Push the handle completely 2 in the direction of the arrow until the locking mechanism engag...

Page 113: ...fore removing an HDD SSD module that is not defective 7 3 1 Preliminary steps Ê Ensure that the HDD SSD module to be removed is not combined into a RAID array If the drive is part of a RAID array you first need to delete the array using ServerView RAID Manager V CAUTION All data on all HDDs SSDs in the array will be lost Be sure to back up your data before deleting a RAID array I For further infor...

Page 114: ... lever together 1 2 Push the handle of the HDD SSD module fully in the direction of the arrow 2 The HDD SSD module is now unlocked Ê Pull the HDD SSD module out a few centimeters Ê Wait for at least 30 seconds I This is not necessary when removing a solid state drive I This period is necessary for the RAID controller to recognize that an HDD module has been removed and for the hard disk drive to c...

Page 115: ...le V CAUTION Only remove an HDD SSD module during operation if the drive is not currently being accessed Observe the indicators for the corresponding HDD SSD modules see RX200 S8 Server Operating Manual Under no circumstances should you remove an HDD SSD module while the system is in operation if you are not sure that the drive is operated by a RAID controller and belongs to a disk array that is o...

Page 116: ... the drive to Offline via the software RAID controller configuration software before removing an HDD SSD module that is not defective 7 4 1 Preliminary steps Ê Locating the defective server on page 43 Ê Locating the defective component on page 45 7 4 2 Removing the defective 2 5 inch HDD SSD module Ê Remove the HDD SSD module as described in section Removing the 2 5 inch HDD SSD module on page 114...

Page 117: ...cess to the component on page 47 7 5 2 Removing the defective 4xHDD backplane Ê Release all HDD SSD modules and pull them out a few centimeters see section Removing the 2 5 inch HDD SSD module on page 114 I The HDD SSD modules need not to be completely removed But if you want to completely remove them nevertheless check if all HDD SSD modules are uniquely identified so that you can reinsert them i...

Page 118: ...cables from the 4xHDD backplane Ê Disconnect the following cables from the 4xHDD backplane 1 SAS SATA data cable from connector CN1 2 power cable from connector CN20 3 I2 C cable HDD monitoring from connector CN14 if applicable 4 ODD cable from connector CN18 For the cable plan see section Cabling on page 314 ...

Page 119: ...ke the 4xHDD backplane from the hooks 7 5 3 Installing the new 4xHDD backplane Figure 48 Installing the 4xHDD backplane Ê Position the 4xHDD backplane on the hooks Ê Push the 4xHDD backplane downward Make sure that the lower cant of the 4xHDD backplane fits in the guides see close up V CAUTION Ensure that none of the cables are strained or damaged Ê Connect the cables to the 4xHDD backplane as sho...

Page 120: ...placement 7 5 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 7 6 Replacing the 8xHDD backplane 7 6 1 Preliminary steps Ê Locating the defective server on page 43 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the air ...

Page 121: ...ou can reinsert them into their original bays Figure 49 Disconnecting cables from the 8xHDDbackplane Ê Disconnect the following cables from the 8xHDD backplane 1 SAS data cable channel A from connector CN1 2 power cable from connector CN20 3 I2 C cable HDD monitoring from connector CN14 if applicable Ê Disconnect the SAS data cable 4 from the RAID controller connector MLC1 For the cable plan see s...

Page 122: ...move the four screws 1 Ê Push the fan cage somewhat in direction of the arrow 2 to disengage the hooks see close up Ê Remove the fan cage upward 3 Figure 51 Removing the 8xHDD backplane Ê Pull the 8xHDD backplane upward until the lower cant gets out of the guides see close up Ê Take the 8xHDD backplane from the hooks ...

Page 123: ... 5 SGPIO connector from connector CN8 For the cable plan see section Cabling on page 314 7 6 3 Installing the new 8xHDD backplane Ê Connect the SAS data cable to the 8xHDD backplane as shown in figure 52 Figure 53 Installing the 8xHDD backplane Ê Position the 8xHDD backplane on the hooks Ê Push the 8xHDD backplane downward Make sure that the lower cant of the 8xHDD backplane fits in the guides see...

Page 124: ...134 I Make sure that you reinstall the fan module in the bay it was located before the 8xHDD backplane replacement Ê Connect the cables to the 8xHDD backplane as shown in figure 49 Ê Insert all HDD SSD modules see section Installing the 2 5 inch HDD SSD module on page 112 I Make sure that you reinstall the HDD SSD module in the bay it was located before the 8xHDD backplane replacement 7 6 4 Conclu...

Page 125: ...e 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the air duct on page 62 7 7 2 Removing the 4xHDD backplane and the ODD cage Ê Remove the 4xHDD backplane as described in section Removing the defective 4xHDD backplane on page 117 Ê If applicable remove the ODD from its bay Upgrade and Repair Unit URU Hardware 15 minutes Tools Replacin...

Page 126: ... Manual RX200 S8 Hard disk drives solid state drives Figure 55 Removing the ODD cable Ê Disconnect the ODD cable from the connector SATA 1 on the system board see circle Figure 56 Removing the screw Ê Remove the screw see circle ...

Page 127: ...id state drives Figure 57 Removing the ODD cage Ê Remove the ODD cage frontward Ê Thread the ODD cable through the opening 7 7 3 Installing the 2xHDD cage and the 8xHDD backplane Figure 58 Installing the 2xHDD cage Ê Push the 2xHDD cage as far as possible in the bay ...

Page 128: ...tive 8xHDD backplane on page 121 Ê If applicable install a 2 channel RAID controller as described in section Installing an expansion card slot 4 on page 157 Ê Install the 8xHDD backplane as described in section Installing the new 8xHDD backplane on page 123 Figure 60 Removing the HDD locks Ê Pull out the two HDD locks frontward Ê Remove the two dummy modules as described in section Removing the 2 ...

Page 129: ...ch HDD SSD module on page 112 I Make sure that you install the HDD SSD modules in the sequence described in section Configuration with up to eight HDD SSD modules on page 109 7 7 4 Concluding steps Ê Installing the air duct on page 62 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 ...

Page 130: ...130 Upgrade and Maintenance Manual RX200 S8 Hard disk drives solid state drives ...

Page 131: ...and can be damaged by static electricity Before handling them first touch a metal part of the server to discharge static electricity from your body Do not touch the circuitry on boards or soldered parts Hold the metallic areas or the edges of the circuit boards If devices are installed or disassembled using methods other than those outlined in this chapter the warranty will be invalidated The inst...

Page 132: ...ancy In other words if one of the four or six fan modules fails the system will operate without any problem The failed fan module can be exchanged without shutting down the server Figure 61 Numbering of the fan modules INDICATE CSS Battery CPU 2 DIMM 3F CPU 2 DIMM 2F CPU 2 DIMM 1E CPU 2 DIMM 2E CPU 2 DIMM 3E CPU 2 DIMM 1F CPU 2 DIMM 1G CPU 2 DIMM 2G CPU 2 DIMM 3H CPU 2 DIMM 2H CPU 2 DIMM 1H CPU 2 ...

Page 133: ...e server on page 43 Ê Extending the server out of the rack on page 48 Ê Removing the fan cover on page 51 Ê Locating the defective component on page 45 8 2 2 Removing the defective fan module Figure 62 Removing the fan module Ê Take out the fan module upward Customer Replaceable Unit CRU Hardware 10 minutes Tools tool less ...

Page 134: ... engage 3 8 2 4 Concluding steps Ê Installing the fan cover on page 53 Ê Sliding the server into the rack on page 56 Ê Performing a fan test after replacing a defective fan on page 89 I When a fan module fails the remaining fan modules will start operating at full speed After the defective fan module has been replaced all fan modules will continue to run at full speed for a couple of minutes befor...

Page 135: ...ving internal options Circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity Always discharge static build up e g by touching a grounded object before handling electrostatic sensitive devices ESDs Do not touch the circuitry on boards or soldered parts Hold circuit boards by their metallic areas or edges If devices are installed or disassembled us...

Page 136: ... Figure 64 Numbering of the riser modules 1 Riser module 1 offers slot 1 2 Riser module 2 offers slot 2 and slot 3 3 Riser module 3 offers slot 4 Slot no Description Slot 1 PCIe 2 x16 low profile half length Slot 2 PCIe 2 x8 low profile half length Slot 3 PCIe 2 x8 low profile half length Slot 4 PCIe 2 x8 low profile half length modular RAID controller only ...

Page 137: ...1 F3740 E701 upgrade kit to 4xGbit onboard D3035 1 1 1 3 4 S26361 F3739 E701 upgrade kit to 6xGbit onboard D3045 1 1 1 3 4 SAS RAID S26361 F3554 E8 based on LSI2008 S26361 D2607 A 1 1 1 2 3 S26361 F3554 E512 based on LSI2108 S26361 D2616 A 1 1 1 2 3 S26361 F3669 E3 based on LSI2208 S26361 D3116 C 1 1 1 2 3 S26361 F3713 E203 LSI MegaRAID SAS 9286CV 8e 1 2 1 1 4 SAS S26361 F3628 E201 LSI SAS9200 8e ...

Page 138: ...1 4 S26361 F3961 E201 Emulex LPe 1250 3 3 2 1 4 S26361 F3961 E202 Emulex LPe 12002 3 3 2 1 4 S26361 F4494 E201 LPe16000 3 3 2 1 4 S26361 F4494 E202 LPe16002 3 3 2 1 4 S26361 F3592 E202 Emulex OCe10102 2 3 2 1 4 Ethernet controller S26361 F3516 E201 Intel Gigabit CT Desktop Adapter Shelter Island 3 3 2 1 4 S26361 F3242 E201 Intel PRO 1000 PF Server Adapter Sheepshead Bay 4 GB s 3 3 2 1 4 S26361 F36...

Page 139: ...cts standard_servers index html for the Japanese market http jp fujitsu com platform server primergy system PCIbus type Max pcs per system Slot no Forbidden slot 1 2 3 4 Ethernet controller D2735 Dual Port Kawela 3 3 2 1 4 D2745 Quad Port Barton Hills 3 3 2 1 4 S26361 F3752 E202 Eth Ctrl X540 T2 2 3 1 2 4 Miscellaneous S26361 F2748 E637 Nvidia NVS300 1 3 2 1 4 S26361 F3749 Exxx USB3 0 PCIe x1 adap...

Page 140: ... LSI MegaRAID Figure 65 Perforated and non perforated slot brackets Installing the slot bracket Ê Place the controller on the mounting tabs on the slot bracket Ê Fasten the slot bracket to the controller with two M3 x 4 5 mm screws Upgrade and Repair Unit URU Hardware 5 minutes Tools Phillips PH2 No 2 screw driver 1 Full height bracket non perforated 2 Full height bracket perforated 3 Low profile ...

Page 141: ...bs on the slot bracket 1 Ê Carefully shift the slot bracket towards the controller until the plug shells engage with the cut outs in the slot bracket connector panel 2 Ê Ensure that the ESD springs on the plug shells properly engage with the slot bracket as shown see circles Figure 67 Fastening the slot bracket D2755 Ê Fasten the slot bracket to the controller with two M3 x 4 5 mm screws ...

Page 142: ...apter D2755 Example network adapter D3035 Figure 69 Placing the slot bracket D3035 Ê Place the controller on the mounting tabs on the slot bracket 1 Ê Carefully shift the slot bracket towards the controller 2 until the plug shells engage with the cut outs in the slot bracket connector panel see close up 햲 햳 ...

Page 143: ... and Maintenance Manual 143 Expansion cards and backup units Figure 70 Fastening the slot bracket D3035 Ê Secure the slot bracket to the controller with two M3 x 4 5 mm screws Figure 71 Assembled network adapter D3035 ...

Page 144: ... the slot bracket D3045 Ê Hinge the slot bracket to the plug shell as shown 1 Ê Fold the slot bracket towards the controller until the threaded mounting tab is aligned with the screw hole on the controller 2 Figure 73 Fastening the slot bracket D3045 Ê Secure the slot bracket to the controller with one M3 x 4 5 mm screw 햲 햳 ...

Page 145: ...ts Figure 74 Assembled network adapter D3045 9 2 2 Removing a slot bracket Removing the slot bracket Ê Remove the two screws Ê Remove the controller from the mounting tabs on the slot bracket Upgrade and Repair Unit URU Hardware 5 minutes Tools Phillips PH2 No 2 screw driver ...

Page 146: ...dules Preparing the SFP transceiver module Figure 75 Removing the protective optical port plug Ê Remove the SFP transceiver module from its protective packaging Ê Remove the optical port plug from the new additional SFP transceiver module V CAUTION Always keep the protective port plugs attached to the transceiver optical bores and fiber optic cable connectors until you are ready to make a connecti...

Page 147: ...and fold down the locking bail on the SFP transceiver module Inserting the SFP transceiver module Figure 77 Installing the first SFP transceiver module Ê Insert and slide the SFP transceiver module into the socket connector as far as it will go I If only one slot is equipped with a SFP transceiver module use the left connector as shown ...

Page 148: ...e 78 Latching the locking bail Ê Carefully fold up and latch the locking bail Figure 79 Installing the protective optical port plug Ê If the SFP transceiver module is not immediately connected to an LC connector attach the protective optical port plug to the transceiver optical bores ...

Page 149: ... SFP transceiver module Ê If applicable install the secondary SFP transceiver module accordingly 9 3 2 Removing an SFP transceiver module For Fiber Channel over Ethernet FCoE configurations the ethernet server adapter is equipped with one or two SFP small form factor pluggable transceiver modules Upgrade and Repair Unit URU Hardware 5 minutes Tools tool less ...

Page 150: ... port plug Ê If present remove the protective optical port plug from the SFP transceiver module V CAUTION Save the protective port plug for future use Figure 82 Unlatching the locking bail Ê Carefully unlatch and fold down the locking bail on the SFP transceiver module to eject the transceiver from the socket connector ...

Page 151: ...Figure 83 Removing the SFP transceiver module Ê Pull the SFP transceiver module out of its socket connector Ê Attach the protective optical port plug to the transceiver optical bores I Place the removed SFP transceiver module in an antistatic bag or other protective environment ...

Page 152: ...ge 63 Ê Disabling SVOM boot watchdog functionality on page 64 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Remove the corresponding riser module as described in section Removing the riser module 1 on page 58 or Removing the riser module 2 on page 59 Upgrade and Repair Unit URU Hardware 10 minutes Software ...

Page 153: ...emoving the slot cover slot 2 1 and slot 3 2 Ê Pull out the slot cover of the corresponding slot V CAUTION Keep the slot cover for future use If the expansion card is removed and not replaced with a new one the slot cover must be reinstalled due to cooling to comply with applicable EMC regulations regulations on electromagnetic compatibility and to protect against fire ...

Page 154: ...pansion cards and backup units 9 4 1 3 Installing the expansion card slot 1 3 Ê Please read the documentation supplied with the expansion card Figure 86 Installing the expansion card slot 1 Figure 87 Installing the expansion card slot 2 A B 0 A B 0 ...

Page 155: ...88 Installing the expansion card slot 3 Ê Carefully press the expansion card into the riser card slot A until it clicks into place 1 Make sure that the lug on the slot cover B clicks into place in the corresponding hole 2 Figure 89 Example connecting NCSI cable to expansion card A B 0 ...

Page 156: ... a shared LAN interface that allows both management and dedicated LAN connections 9 4 1 4 Concluding steps Ê Installing the riser module 1 on page 59 or Installing the riser module 2 on page 60 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Updating RAID controller firmware on page 73 Ê If applicable Enabling Option ROM scan on page...

Page 157: ...lity on page 64 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the riser module 3 on page 60 9 4 2 2 Installing the expansion card slot 4 Ê Please read the documentation supplied with the expansion card Figure 91 Installing the expansion card slot 4 Upgrade and Repair Unit URU Hardware 10 minutes So...

Page 158: ...ecting cables Ê If necessary connect the cables to the expansion card 9 4 2 3 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Updating RAID controller firmware on page 73 Ê If applicable Enabling Option ROM scan on page 74 Ê Enabling SVOM boot watchdog functionality on page ...

Page 159: ...server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Remove the corresponding riser module as described in section Removing the riser module 1 on page 58 or Removing the riser module 2 on page 59 9 4 3 2 Removing the expansion card slot 1 3 Figure 93 Removing the expansion card slot 1 Upgrade and Repair Unit URU Hardware 5 minutes To...

Page 160: ...8 Expansion cards and backup units Figure 94 Removing the expansion card slot 2 Figure 95 Installing the expansion card slot 3 Ê If necessary disconnect the cables from the expansion cards Ê Pull out the expansion card from the riser card slot ...

Page 161: ... 3 3 Installing the slot cover slot 1 3 Figure 96 Installing the slot cover slot 1 Figure 97 Installing the slot cover slot 2 1 and slot 3 2 Ê Insert the slot cover of the corresponding slot Make sure that the lug on the slot cover A clicks into place in the corresponding hole A A ...

Page 162: ...Ê Enabling BitLocker functionality on page 83 9 4 4 Removing an expansion card slot 4 9 4 4 1 Preliminary steps Ê Disabling BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the riser module 3 on page 60 9 4 4 2 Removing the expansion card slot 4 Ê If necessary discon...

Page 163: ...e the expansion card from the distance holder 1 Ê Pull out the expansion card from the riser card slot 2 9 4 4 3 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Enabling BitLocker functionality on page 83 ...

Page 164: ...If applicable ensure to note down your current network settings in the operating system Ê Disabling SVOM boot watchdog functionality on page 64 Ê Disabling BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Locating the defective component on page 45 Ê Remove the corresponding ...

Page 165: ...atchdog functionality on page 78 Ê Switching on the server on page 58 Ê Enabling BitLocker functionality on page 83 Ê After replacing a network controller in a server running Linux OS Updating the NIC configuration file in a Linux environment on page 82 Ê If applicable reconfigure your network settings in the operation system according to the original configuration of the replaced controller expan...

Page 166: ... the component on page 47 Ê Locating the defective component on page 45 Ê Remove the corresponding riser module as described in section Handling riser modules on page 58 9 4 6 2 Removing the defective riser card Ê Remove the expansion card as described in section Removing the expansion card slot 1 3 on page 159 or Removing the expansion card slot 4 on page 162 Figure 99 Removing the riser card slo...

Page 167: ...grade and Maintenance Manual 167 Expansion cards and backup units Figure 100 Removing the riser card slot 2 and slot 3 Figure 101 Removing the riser card slot 4 Ê Remove the two screws 1 Ê Remove the riser card 2 ...

Page 168: ...grade and Maintenance Manual RX200 S8 Expansion cards and backup units 9 4 6 3 Installing the new riser card Figure 102 Installing the riser card slot 1 Figure 103 Installing the riser card slot 2 and slot 3 ...

Page 169: ...Ê Install the expansion card as described in section Installing the expansion card slot 1 3 on page 154 or Installing the expansion card slot 4 on page 157 9 4 6 4 Concluding steps Ê Install the corresponding riser module as described in section Handling riser modules on page 58 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 ...

Page 170: ... 47 Ê Getting access to the component on page 47 Ê Locating the defective component on page 45 Ê Removing the riser module 3 on page 60 9 4 7 2 Removing the defective TFM Ê Remove the depending expansion card as described in section Removing an expansion card slot 4 on page 162 Figure 105 Disconnecting the FBU cable from the TFM Ê Disconnect the FBU cable from the TFM Upgrade and Repair Unit URU H...

Page 171: ...Ê Connect the FBU cable to the TFM V CAUTION Make sure that the connector side with the three dots is on the top Otherwise you risk short circuits Do not connect the cable using excessive force the connector is weak Ê Install the expansion card as described in section Installing an expansion card slot 4 on page 157 9 4 7 4 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling ...

Page 172: ...it 9 5 2 Installing a BBU 9 5 2 1 Preliminary steps Ê Disabling SVOM boot watchdog functionality on page 64 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the riser module 3 on page 60 9 5 2 2 Connecting the BBU cable to the BBU I The BBU cable is available in different length You need the short cab...

Page 173: ...e BBU V CAUTION Make sure that the connector side with the three dots is on the top see close up Otherwise you risk short circuits 9 5 2 3 Installing the BBU in the holder Figure 108 Installing the BBU in the holder Ê At a slight angle fit the BBU under the right retaining bracket on the holder 1 Ê Fold down the BBU until it locks in place 2 ...

Page 174: ...with the holder Figure 109 Position of the shoulder screw caps Figure 110 Installing the BBU with the holder Ê Insert the holder into the chassis so that the three shoulder screw caps on the chassis floor rest in the wide ends of the keyhole slots on the holder Ê Slide the holder in direction of the arrow ...

Page 175: ... properly snaps in place see circle Figure 111 Connecting the BBU cable to the RAID controller Ê Install a RAID controller as described in section Installing the expansion card slot 4 on page 157 Ê Connect the BBU cable to the RAID controller see circle V CAUTION Make sure that the connector side with the three dots is on the top Otherwise you risk short circuits Do not connect the cable using exc...

Page 176: ...he BBU cable Example A Figure 113 Routing the BBU cable Example B Ê Route the BBU cable as shown in the figure 9 5 2 5 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Updating RAID controller firmware on page 73 ...

Page 177: ...erverView Suite RAID Management user guide Ê If the BBU is shown as bad or defective do not power off the server for at least 12 hours to allow the charge and calibration cycles to finish Ê If the BBU status does not change after 12 hours please try to initiate the recalibration process manually using the ServerView RAID Manager I If this procedure still does not fix the BBU status please contact ...

Page 178: ... and backup units 9 5 3 2 Installing TFM to the RAID controller if applicable Figure 114 TFM kit Figure 115 Installing TFM Ê Fit the spacer bolts of the TFM on the RAID controller 1 Ê Secure the TFM on the RAID controller with the three screws 2 1 TFM 2 Screws ...

Page 179: ...e FBU in the holder Figure 116 Installing the FBU in the holder A Ê At a slight angle fit the FBU under the right retaining bracket on the holder Ê Push down the FBU until it locks in place Figure 117 Installing the FBU in the holder B Ê Ensure that the FBU is properly seated in the holder as shown ...

Page 180: ...U cable to the FBU I The FBU cable is available in different length You need the short cable if the used RAID controller is installed in slot 4 Figure 118 Connecting the FBU cable Ê Connect the FBU cable to the FBU 9 5 3 5 Installing the FBU with the holder Figure 119 Position of the shoulder screw caps ...

Page 181: ... keyhole slots on the holder Ê Slide the holder in direction of the arrow The shoulder screw caps on the chassis floor will lock in the narrow ends of the keyhole slots on the holder Ê Ensure that the locking handle on the holder properly snaps in place see circle Figure 121 Connecting the FBU cable to the RAID controller Ê If applicable install a RAID controller in slot 3 as described in section ...

Page 182: ...al RX200 S8 Expansion cards and backup units Ê Connect the FBU cable to the RAID controller see circle Figure 122 Routing the FBU cable Example A Figure 123 Routing the FBU cable Example B Ê Route the FBU cable as shown in the figure ...

Page 183: ...hing on the server on page 58 9 5 4 Removing a BBU V CAUTION Dispose of used battery properly Keep away from children Do not throw battery backup units into the trash can Batteries must be disposed of in accordance with local regulations concerning special waste 9 5 4 1 Preliminary steps Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to ...

Page 184: ...d backup units 9 5 4 2 Removing the BBU with the holder Figure 124 Disconnecting the BBU cable from the RAID controller Ê Disconnect the BBU cable from the RAID controller see circle V CAUTION Do not disconnect the cable using excessive force the connector is weak ...

Page 185: ... with the holder Ê Lift up the green locking handle on the holder see circle while sliding the holder in direction of the arrow as far as it will go I After that the shoulder screw caps on the chassis floor will rest in the wide ends of the keyhole slots on the holder Ê Lift the holder out of the chassis ...

Page 186: ...ress out on the retaining bracket on the holder 1 lift the battery at the bottom side and remove the BBU at a slight angle out of the holder 2 9 5 4 4 Disconnecting the BBU cable from the BBU Figure 127 Disconnecting the BBU cable from the BBU Ê Disconnect the BBU cable from the BBU V CAUTION Do not disconnect the cable using excessive force the connector is weak 0 ...

Page 187: ...U V CAUTION Dispose of used battery properly Keep away from children Do not throw flash backup units into the trash can Batteries must be disposed of in accordance with local regulations concerning special waste 9 5 5 1 Preliminary steps Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the riser modul...

Page 188: ... disconnect the FBU cable from the RAID controller see circle Figure 129 Removing the FBU with the holder Ê Lift up the green locking handle on the holder see circle while sliding the holder in direction of the arrow as far as it will go I After that the shoulder screw caps on the chassis floor will rest in the wide ends of the keyhole slots on the holder Ê Lift the holder out of the chassis ...

Page 189: ... 9 5 5 3 Disconnecting the FBU cable from the FBU Figure 130 Disconnecting the FBU cable from the FBU Ê Disconnect the FBU cable from the FBU 9 5 5 4 Removing the FBU from the holder Figure 131 Removing the FBU from the holder Ê Pull the FBU at a slight angle out of the holder ...

Page 190: ...of in accordance with local regulations concerning special waste 9 5 6 1 Preliminary steps Ê Disabling SVOM boot watchdog functionality on page 64 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the riser module 3 on page 60 9 5 6 2 Removing the defective BBU Ê Remove the BBU with the holder as descr...

Page 191: ...Ê Connecting the server to the mains on page 57 Ê Updating RAID controller firmware on page 73 Ê Enabling SVOM boot watchdog functionality on page 78 Ê Switching on the server on page 58 Note on BBU charging and calibration The BBU may be deeply discharged due to extended storage time and wrongly show as bad or defective in the ServerView RAID Manager In this case the BBU will automatically enter ...

Page 192: ...h local regulations concerning special waste 9 5 7 1 Preliminary steps Ê Disabling SVOM boot watchdog functionality on page 64 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the riser module 3 on page 60 9 5 7 2 Removing the defective FBU Ê Remove the FBU with the holder as described in section Remo...

Page 193: ...cribed in section Connecting the FBU cable to the FBU on page 180 Ê Install the FBU with the holder as described in section Installing the FBU with the holder on page 180 9 5 7 4 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Updating RAID controller firmware on page 73 Ê Enabling SVOM boot watchdog functional...

Page 194: ...194 Upgrade and Maintenance Manual RX200 S8 Expansion cards and backup units ...

Page 195: ...own before installing or removing memory modules to prevent burns Do not insert and remove memory modules repeatedly Doing so may cause failures If the memory module has not been correctly inserted it may cause a fire Insert the memory module with attention to its direction Pressing out the securing clips on the memory module connector will eject the installed memory module To prevent damage and i...

Page 196: ...8 GB 16 GB 32 GB or 64 GB Maximum amount of RAM 1536 GB INDICATE CSS Battery CPU 2 DIMM 3F CPU 2 DIMM 2F CPU 2 DIMM 1E CPU 2 DIMM 2E CPU 2 DIMM 3E CPU 2 DIMM 1F CPU 2 DIMM 1G CPU 2 DIMM 2G CPU 2 DIMM 3H CPU 2 DIMM 2H CPU 2 DIMM 1H CPU 2 DIMM 3G CPU 1 DIMM 1A CPU 1 DIMM 2A CPU 1 DIMM 3B CPU 1 DIMM 2B CPU 1 DIMM 1B CPU 1 DIMM 3A CPU 1 DIMM 3D CPU 1 DIMM 2D CPU 1 DIMM 1C CPU 1 DIMM 2C CPU 1 DIMM 3C C...

Page 197: ...ank 1DPC 1 DIMM per Channel 2DPC 2 DIMM per Channel 3DPC 3 DIMM per Channel DPC CPU with 1866MHz DDR3 Bus 1600 1333 1866 1600 1066 1333 1333 1866 1600 1066 1600 1600 1066 1866 1333 1333 1066 DPC DPC DPC DPC DPC 1 2 800 800 1 2 2 3 1333 1333 Mem Speed provided by CPU Real maximum memory bus speed depending on CPU type memory configuration DPC and voltage setting BIOS UDIMM 1866MHz RDIMM 1866MHz LRD...

Page 198: ...irst starting from slot 1 If memory modules with different capacities are used Populate modules with higher capacities first Within a channel populate modules in descending order of capacity If memory modules with different speeds are used the lowest clock rate applies for all DIMMs Regardless of the mode all DIMMs will run at the highest common frequency that is allowed by the SPD Data of the DIM...

Page 199: ... 1 5 3 2 6 4 7 1 5 7 3 2 6 4 8 1 5 7 3 2 6 8 4 9 1 9 5 7 3 2 6 8 4 10 1 9 5 7 3 2 10 6 8 4 11 1 9 5 7 3 11 2 10 6 8 4 12 1 9 5 7 3 11 2 10 6 8 4 12 13 1 9 5 13 7 3 11 2 10 6 8 4 12 14 1 9 5 13 7 3 11 2 10 6 14 8 4 12 15 1 9 5 13 7 15 3 11 2 10 6 14 8 4 12 16 1 9 5 13 7 15 3 11 2 10 6 14 8 16 4 12 17 1 9 17 5 13 7 15 3 11 2 10 6 14 8 16 4 12 18 1 9 17 5 13 7 15 3 11 2 10 18 6 14 8 16 4 12 19 1 9 17...

Page 200: ...ltiples of 4 Same numbers mean identical modules capacity rank 2 U P C 1 U P C U P C Channel A B D C E F H G DIMM 1A 2A 3A 1B 2B 3B 1D 2D 3D 1C 2C 3C 1E 2E 3E 1F 2F 3F 1H 2H 3H 1G 2G 3G n o i t a r u g i f n o c U P C o n o M s M M I D 4 1 1 1 1 8 1 2 1 2 1 2 1 2 12 1 2 3 1 2 3 1 2 3 1 2 3 n o i t a r u g i f n o c U P C l a u D s M M I D 8 1 1 1 1 2 2 2 2 12 1 3 1 3 1 3 1 3 2 2 2 2 16 1 3 1 3 1 3...

Page 201: ...on if all modules are of the same capacity 4 o o o o 5 o o o o o 6 o o o o o o 7 o o o o o o o 8 o o o o o o o o 9 o o o o o o o o o 10 o o o o o o o o o o 11 o o o o o o o o o o o 12 o o o o o o o o o o o o 13 o o o o o o o o o o o o o 14 o o o o o o o o o o o o o o 15 o o o o o o o o o o o o o o o 16 o o o o o o o o o o o o o o o o 17 o o o o o o o o o o o o o o o o o 18 o o o o o o o o o o o o ...

Page 202: ...al CPU configuration if modules are of different capacities Dual CPU configuration if modules are of different capacities 2 o o 2 o o 3 o o o 3 o o o 4 o o o o 4 o o o o 5 o o o o o 5 o o o o o 6 o o o o o o 6 o o o o o o 7 o o o o o o o 7 o o o o o o o 8 o o o o o o o o 8 o o o o o o o o 9 o o o o o o o o o 9 o o o o o o o o o 10 o o o o o o o o o o 10 o o o o o o o o o o 11 o o o o o o o o o o o...

Page 203: ...of the same capacity 2 o o 3 o o o 4 o o o o 5 o o o o o 6 o o o o o o 7 o o o o o o o 8 o o o o o o o o 9 o o o o o o o o o 10 o o o o o o o o o o 11 o o o o o o o o o o o 12 o o o o o o o o o o o o 13 o o o o o o o o o o o o o 14 o o o o o o o o o o o o o o 15 o o o o o o o o o o o o o o o 16 o o o o o o o o o o o o o o o o 17 o o o o o o o o o o o o o o o o o 18 o o o o o o o o o o o o o o o o ...

Page 204: ...this case proceed as follows Ê Use the capacity group with more memory modules for CPU 1 and populate them according to the population sequence for mono CPU configurations Ê Populate the other capacity group on CPU 2 according to the population rules for mono CPU configurations 2 U P C U P C 1 U P C U P C Ch A B D C Ch E F H G DIMM 1A 2A 3A 1B 2B 3B 1D 2D 3D 1C 2C 3C DIMM 1E 2E 3E 1F 2F 3F 1H 2H 3...

Page 205: ...r functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the air duct on page 62 10 2 2 Selecting the memory slot Ê Choose the memory slot according to the configuration rules in Basic information on page 196 Order CPU 1 CPU 2 1 Channel A Channel E 2 Channel C Channel G 3 Channel B ...

Page 206: ...arefully press the memory module into the memory slot 1 until the securing clips on both sides of it engage 2 10 2 4 Concluding steps Ê Installing the air duct on page 62 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Updating or recovering the system board BIOS and iRMC on page 70 Ê Enabling SVOM boot watchdog functionality on page 78 Ê Switching on the server on page...

Page 207: ...e 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the air duct on page 62 10 3 2 Removing a memory module Figure 136 Removing the memory module Ê Press the securing clips on both sides of the memory slot concerned outward 1 Ê Pull the memory module out of the slot 2 Upgrade and Repair Unit URU Hardware 5 minutes Tools tool less ...

Page 208: ...e defective server on page 43 Ê Disabling SVOM boot watchdog functionality on page 64 Ê Disabling BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the air duct on page 62 Ê Locating the defective component on page 45 10 4 2 Removing the defective memory module Ê Remo...

Page 209: ... Installing the air duct on page 62 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Updating or recovering the system board BIOS and iRMC on page 70 Ê Enabling replaced components in the system BIOS on page 79 Ê Verifying the memory mode on page 79 Ê Enabling SVOM boot watchdog functionality on page 78 Ê Switching on the server on page 58 Ê Enabling BitLocker functional...

Page 210: ...210 Upgrade and Maintenance Manual RX200 S8 Main memory ...

Page 211: ...up e g by touching a grounded object before handling electrostatic sensitive devices ESDs Do not touch the circuitry on boards or soldered parts Hold circuit boards by their metallic areas or edges When removing or installing the processor be careful not to touch or bend the spring contacts on the processor socket Never touch the underside of the processor Even minor soiling such as grease from th...

Page 212: ...ator available online at the following address for the EMEA market http ts fujitsu com products standard_servers index html for the Japanese market http jp fujitsu com platform server primergy system 11 1 2 General equipping rules Both CPUs must be of the same type INDICATE CSS CPU 2 DIMM 3F CPU 2 DIMM 2F CPU 2 DIMM 1G CPU 2 DIMM 2G CPU 2 DIMM 3H CPU 2 DIMM 2H CPU 2 DIMM 1H CPU 2 DIMM 3G CPU 1 DIM...

Page 213: ...sors of the same type may be used on the system board That means the number of the internal processor cores as well as the primary clock and the QPI frequency have to be the same For dual operation use a suitable multiprocessor operating system 11 2 1 Preliminary steps Ê Disabling SVOM boot watchdog functionality on page 64 Ê Disabling BitLocker functionality on page 63 Ê Shutting down the server ...

Page 214: ...latch the socket release lever marked Open 1st by pushing it down and away from the socket 1 Ê The socket release lever will slightly lift up 2 Figure 139 Opening socket release lever 2 Ê Unlatch the socket release lever marked Close 1st by pushing it down and away from the socket 1 Ê Fully fold back the second socket release lever 2 ...

Page 215: ...Opening the load plate A Ê Push down on the first socket release lever 1 to lift the load plate away from the socket 2 Figure 141 Opening the load plate B Ê Fully open the load plate V CAUTION Be careful not to touch or bend the spring contacts on the processor socket ...

Page 216: ...or align with the posts on the socket see close up Ê Lower the processor straight down without tilting or sliding it in the socket V CAUTION Ensure that the processor is level in the socket Be careful not to touch or bend the pins on the processor socket Never touch the underside of the processor Even minor soiling such as grease from the skin can impair the processor s operation or destroy the pr...

Page 217: ...r the load plate over the processor Figure 144 Removing the protective socket cover Ê When closing the load plate the protective socket cover will automatically detach Ê Remove the socket cover and save it for future use V CAUTION Always replace the socket cover if you remove the processor from the socket ...

Page 218: ...close and hold shut the load plate Ê Close the socket release lever marked Close 1st 1 and latch it under the load plate retention tab to lock down the load plate 2 Figure 146 Closing socket release lever 1 Ê Close the socket release lever marked Open 1st 1 and latch it under the load plate retention tab 2 ...

Page 219: ... the heat sink I Processors with 135W need dedicated heat sinks part number V26898 B964 V3 Figure 147 Heat sink part number V26898 B964 V3 Ê Remove the protective cover from the heat sink V CAUTION Ensure not to touch the heat conductive paste on the bottom of the heat sink ...

Page 220: ...the threaded holes Ensure that the heat sink cooling fins match the direction of the airflow Ê Fasten it in a crossover pattern with four screws according to the numbering torque 1 0 Nm the description of this torque value doesn t apply to the Japanese market 11 2 4 Upgrading the main memory Ê Select an adequate memory configuration for Two CPUs populated as described in section Memory sequence on...

Page 221: ...es from the system fan bays FAN 7 8 and FAN 9 10 Figure 150 Installed fan modules Ê Install two fan modules in the system fan bays FAN 7 8 and FAN 9 10 as described in section Installing the new fan module on page 134 11 2 6 Concluding steps Ê Installing the air duct on page 62 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 ...

Page 222: ... a processor has been removed from its protective sleeve or from its socket place it with its smooth side down on a non conducting antistatic surface Never push a processor over a surface 11 3 1 Preliminary steps Ê Locating the defective server on page 43 Ê Disabling SVOM boot watchdog functionality on page 64 Ê Disabling BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê D...

Page 223: ... processor I This may be necessary due to the adhesive quality of the thermal paste located between the heat sink and the processor V CAUTION Pay special attention not to damage any system board components surrounding the processor socket Ê Lift the heat sink out of the chassis Ê Remove the residual thermal paste from the underside of the heat sink and the surface of the processor Ê Clean the unde...

Page 224: ...Ê Unlatch the socket release lever marked Open 1st by pushing it down and away from the socket 1 Ê The socket release lever will slightly lift up 2 Figure 153 Opening socket release lever 2 Ê Unlatch the socket release lever marked Close 1st by pushing it down and away from the socket 1 Ê Fully fold back the second socket release lever 2 ...

Page 225: ...ance Manual 225 Processors Figure 154 Opening the load plate A Ê Push down on the socket release lever marked Open 1st 1 to lift the load plate away from the socket 2 Figure 155 Opening the load plate B Ê Fully open the load plate ...

Page 226: ...an residual thermal paste from the processor surface using a lint free cloth Ê If the processor is being replaced during a CPU upgrade and may be reused later store it in a save place V CAUTION Processors are extremely sensitive to electrostatic discharge and must be handled with care After a processor has been removed from its protective sleeve or from its socket place it upside down on a noncond...

Page 227: ...tches on the processor align with the posts on the socket see close up Ê Lower the processor straight down without tilting or sliding it in the socket V CAUTION Ensure that the processor is level in the socket Be careful not to touch or bend the pins on the processor socket Never touch the underside of the processor Even minor soiling such as grease from the skin can impair the processor s operati...

Page 228: ...e over the processor V CAUTION Always replace the socket cover if you remove the processor from the socket Figure 159 Closing socket release lever 2 Ê Fully close and hold shut the load plate Ê Close the socket release lever marked Close 1st 1 and latch it under the load plate retention tab to lock down the load plate 2 ...

Page 229: ...tention tab 2 11 3 5 Applying the thermal paste to the processor surface I For the Japanese market the service engineer must follow the instruction provided separately If the processor replacement kit contains a new heat sink a thin layer of thermal compound has already been pre applied to its lower surface In this case please proceed with section Installing the heat sink on page 231 ...

Page 230: ...ompound syringe FTS FSP P304000004 contains thermal paste for three processors Figure 162 Applying the thermal paste Ê Apply a small point shaped amount of thermal paste 1 0 gram see description above to the center of the processor surface as shown V CAUTION Do not mix different types of thermal paste ...

Page 231: ...processor socket Ê Position the screws in the holes carefully making sure they are upright V CAUTION Ensure that the screws on the heat sink are properly seated on the threaded holes Ensure that the heat sink cooling fins match the direction of the airflow see airflow label Ê Fasten it in a crossover pattern with four screws according to the numbering torque 1 0 Nm the description of this torque v...

Page 232: ... 83 11 4 Replacing a heat sink 11 4 1 Preliminary steps Ê Locating the defective server on page 43 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the air duct on page 62 11 4 2 Removing the defective heat sink Ê Remove the heat sink as described in section Removing the heat sink on page 223 Ê Remove...

Page 233: ...5W need dedicated heat sinks part number V26898 B964 V3 Ê Install the heat sink as described in section Installing the heat sink on page 219 11 4 4 Concluding steps Ê Installing the air duct on page 62 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 ...

Page 234: ...234 Upgrade and Maintenance Manual RX200 S8 Processors ...

Page 235: ...ircuit boards The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity Before handling them first touch a metal part on the server to discharge static electricity from your body Before installing an internal accessible drive see the manual for the accessible drive When forcing an accessible drive into a server be careful so as not to pinch the ...

Page 236: ... Disabling BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 12 2 2 Removing the dummy module Figure 164 Removing the dummy module Upgrade and Repair Unit URU Hardware 10 minutes Tools tool less ...

Page 237: ... frame Ê Pull the mounting frame outward on both sides 1 Ensure that the pins on the mounting frame disengage with the screw holes on the dummy see circles Ê Remove the dummy 2 V CAUTION Keep the dummy for future use If you remove the accessible drive again and do not replace it with a new one the dummy must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire...

Page 238: ...DD Figure 166 Installing the ODD in the mounting frame Ê Insert the ODD in the mounting frame Ensure that the four pins on the mounting frame engage with the screw holes on the ODD and fix them in this position Figure 167 Installing the ODD Ê Push the ODD into the bay until it clicks in ...

Page 239: ...e 58 Ê Enabling BitLocker functionality on page 83 12 3 Removing the ODD 12 3 1 Preliminary steps Ê Removing backup and optical disk media on page 66 Ê Disabling BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Field Replaceable Unit FRU Hardware 10 minutes Tools tool less ...

Page 240: ...drive 12 3 2 Removing the ODD Figure 168 Removing the ODD Ê Press the lock in direction of the arrow until it disengages 1 Ê Push the ODD out of the bay 2 Figure 169 Removing the ODD out of the mounting frame Ê Pull the mounting frame outward on both sides 1 ...

Page 241: ...ve the ODD 2 12 3 3 Installing the dummy module Figure 170 Installing the dummy in the mounting frame Ê Insert the dummy in the mounting frame Ensure that the pins on the mounting frame engage with the screw holes on the dummy and fix them in this position see circles Figure 171 Installing the dummy module Ê Push the dummy module inward until it engages ...

Page 242: ...on page 75 12 4 Replacing the ODD 12 4 1 Preliminary steps Ê Locating the defective server on page 43 Ê Removing backup and optical disk media on page 66 Ê Disabling BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 12 4 2 Removing the defective ODD Ê Remove the ODD as described...

Page 243: ...stalling the new ODD Ê Install the ODD as described in section Installing the ODD on page 238 12 4 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Enabling BitLocker functionality on page 83 ...

Page 244: ...244 Upgrade and Maintenance Manual RX200 S8 Optical disk drive ...

Page 245: ...VGA and front LAN both or separately Front panel The front panel module consists of the front panel board a front panel and a holder These components are already pre assembled The PRIMERGY RX200 S8 server s chassis ID is stored on both the front panel board and the system board After replacing the front panel module it is necessary to program the ChassisID prom of the front panel board Beside the ...

Page 246: ...tionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the riser module 3 on page 60 13 2 2 Removing the front VGA LAN module Figure 172 Removing the front VGA LAN module Ê Lift up the green touch point 1 Upgrade and Repair Unit URU Hardware 10 minutes Tools tool less ...

Page 247: ...of the bay 2 13 2 3 Removing the covers Figure 173 Removing the covers Ê Break out the cover for the front VGA connector A and or front LAN connector B 13 2 4 Installing the front connectors Installing the front VGA connector Figure 174 Inserting the front VGA connector Ê Insert the front VGA connector from the inside ...

Page 248: ...he front VGA connector Ê Fasten the front VGA connector with the two screws see circles Ê Store the front VGA cable in the guidings A Installing the front LAN connector Ê Turn the front VGA LAN module around Figure 176 Inserting the front LAN connector Ê Thread the front LAN connector through the opening ...

Page 249: ...LAN module Figure 177 Pushing down the front LAN connector Ê Push the front LAN connector down Figure 178 Pushing frontward the front LAN connector Ê Push the front LAN connector to the front side until the hooks engage see close up Ê Turn the front VGA LAN module around ...

Page 250: ...el and front VGA LAN module Figure 179 Storing the front LAN cable Ê Store the front LAN cable in the guidings A 13 2 5 Installing the front VGA LAN module Figure 180 Installing the front VGA LAN module Ê Thread the free ends of the cables through the bay ...

Page 251: ...cting the front VGA cable Figure 181 Connecting the front VGA cable Ê Route the front VGA cable as shown in the photo Ê Connect the front VGA cable to the system board connector FRONT VGA 13 2 7 Connecting the front LAN cable I The front LAN card is already mounted in its holder Figure 182 Connecting the front LAN cable to the front LAN card Ê Connect the front LAN cable to the front LAN card ...

Page 252: ...N card Ê Carefully press the front LAN card with its holder into the FRONT LAN M slot until it clicks into place see circle Figure 184 Routing the front LAN cable Ê Route the front LAN cable in a loop as shown in the figure 13 2 8 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 ...

Page 253: ...ngs enabled Management or Shared For detailed information on how to access the BIOS and modify settings refer to the corresponding BIOS Setup Utility reference manual Ê Connect a client computer e g notebook to the front management LAN connector I It is not possible to simultaneously access the iRMC S4 from the front and rear management LAN connectors As soon as a LAN cable is connected to the fro...

Page 254: ...hutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the riser module 3 on page 60 13 3 2 Disconnecting the front LAN cable Figure 185 Removing the front LAN card Ê Press the two sides of the holder together 1 until the locking mechanism disengages Upgrade and Repair Unit URU Hardware 10 minutes Tools tool l...

Page 255: ...front LAN card out of its slot 2 Figure 186 Disconnecting the front LAN cable from the front LAN card Ê Disconnect the front LAN cable from the front LAN card 13 3 3 Disconnecting the front VGA cable Figure 187 Disconnecting the front VGA cable Ê Disconnect the front VGA cable from the system board connector FRONT VGA ...

Page 256: ...AN module Ê Remove the front VGA LAN module as described in section Removing the front VGA LAN module on page 246 13 3 5 Removing the front connectors Removing the front LAN connector Figure 188 Taking out the front LAN cable Ê Take the front LAN cable out of the guidings A Ê Turn the front VGA LAN module around ...

Page 257: ... panel and front VGA LAN module Figure 189 Pushing inward the front LAN connector Ê Disengage the hooks 1 and simultaneously push the front LAN connector inward 2 Figure 190 Pushing upward the front LAN connector Ê Push the front LAN connector upward ...

Page 258: ...ving the front LAN connector Ê Thread the front LAN connector through the opening and remove it Ê Turn the front VGA LAN module around Removing the front VGA connector Figure 192 Loosening the front VGA connector Ê Take the front VGA cable out of the guidings A Ê Remove the two screws see circles ...

Page 259: ...it 13 3 6 Installing the front VGA LAN module Ê Install the front VGA LAN module as described in section Installing the front VGA LAN module on page 250 13 3 7 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Enabling BitLocker functionality on page 83 ...

Page 260: ...moving the riser module 3 on page 60 13 4 2 Removing the defective front VGA and or front LAN cable Ê Disconnect the front LAN cable as described in section Disconnecting the front LAN cable on page 254 Ê Disconnect the front VGA cable as described in section Disconnecting the front VGA cable on page 255 Ê Remove the front VGA LAN module as described in section Removing the front VGA LAN module on...

Page 261: ...GA cable on page 251 Ê Connect the front LAN cable as described in section Connecting the front LAN cable on page 251 13 4 4 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Enabling BitLocker functionality on page 83 13 5 Replacing the front LAN card 13 5 1 Preliminary steps...

Page 262: ...new front LAN card Ê Connect the front LAN cable as described in section Connecting the front LAN cable on page 251 13 5 4 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Updating the NIC configuration file in a Linux environment on page 82 Ê Looking up changed MAC WWN addre...

Page 263: ...ing the system board the backup data is restored from the front panel board to the new system board V CAUTION For that reason the front panel board and system board must not be replaced simultaneously In this case restoring the system configuration data on the system board would fail 13 6 1 Preliminary steps Ê Locating the defective server on page 43 Ê Disabling SVOM boot watchdog functionality on...

Page 264: ... cable Ê Disconnect the front panel cable from the system board connector Front Panel Ê Take the front panel cable out of the guiding A Ê If applicable disconnect the front LAN cable as described in section Disconnecting the front LAN cable on page 254 Ê If applicable disconnect the front VGA cable as described in section Disconnecting the front VGA cable on page 255 A ...

Page 265: ...e Manual 265 Front panel and front VGA LAN module Figure 195 Removing the ID card and screw Ê Remove the ID card 1 Ê Remove the screw 2 Figure 196 Removing the front panel module Ê Push the front panel module frontward out of the bay ...

Page 266: ...all cables through the opening Figure 197 Removing the front VGA LAN module Ê Lift up the green touch point 1 Ê Push the front VGA LAN module frontward out of the bay 2 Figure 198 Disconnecting the front panel cable Ê Open the cable clamp if applicable 1 Ê Disconnect the front panel cable 2 ...

Page 267: ...ure 199 Removing the front panel frame Ê Press the lock inside 1 Ê Swivel the front panel frame outward 2 Ê Unhook the front panel frame on the left side 3 and remove it Figure 200 Removing the front panel board Ê Remove the two screws 1 Ê Remove the front panel board from the frame 2 ...

Page 268: ...module 13 6 3 Installing the new front panel module Figure 201 Position pins and nose Figure 202 Installing the front panel board Ê Position the front panel board on the frame regarding the pins and the nose 1 Ê Fasten the front panel board to the frame with the two screws 2 ...

Page 269: ...e Figure 203 Installing the front panel frame Ê Hook the front panel frame in on the left side 1 Ê Swivel the front panel frame inward 2 until the lock clicks in 3 Figure 204 Connecting the front panel cable Ê Connect the front panel cable 1 Ê Close the cable clamp if applicable 2 ...

Page 270: ... panel and front VGA LAN module Figure 205 Installing the front VGA LAN module Ê Push the front VGA LAN module into the bay Figure 206 Installing the front panel module Ê Thread all cables through the opening Ê Push the front panel module into the bay ...

Page 271: ... Front panel and front VGA LAN module Figure 207 Inserting screw and ID card Ê Fasten the front panel module with the screw 1 Ê Insert the ID card 2 Figure 208 Connecting the front panel cable Ê Store the front panel cable under the guiding A A ...

Page 272: ... page 251 Ê If applicable connect the front LAN cable as described in section Connecting the front LAN cable on page 251 13 6 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Enabling SVOM boot watchdog functionality on page 78 Ê Using the Chassis ID Prom Tool on page 87 Ê Switching on the server on page 58 Ê Verifying system information backup restore...

Page 273: ...information The serial interface can be installed in the slot cover of riser module 1 slot 1 or in the slot cover of riser module 2 slot 2 14 2 Installing the serial interface Figure 209 Serial interface kit Upgrade and Repair Unit URU Hardware 5 minutes Tools tool less 1 Long slot bracket I The long slot bracket is not used in this server 2 Serial interface with short slot bracket Ԙ ԙ ...

Page 274: ...nt on page 47 14 2 2 Removing the slot cover Ê Remove the riser module 1 or the riser module2 as described in section Handling riser modules on page 58 Ê Remove the slot cover of slot 1 or slot 2 as described in section Removing the slot cover slot 1 3 on page 153 14 2 3 Installing the serial interface Figure 210 Installing the serial interface slot 1 Ê Install the serial interface in slot 1 or sl...

Page 275: ... the serial interface cable Ê Connect the serial interface cable to the system board connector SERIAL 1 14 2 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Enabling BitLocker functionality on page 83 ...

Page 276: ...r on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 14 3 2 Removing the serial interface Figure 212 Disconnecting the serial interface cable Ê Disconnect the serial interface cable from the system board connector SERIAL 1 Ê Remove the riser module 1 or the riser module2 as described in section Handling riser modules on page 58 Upgrade and ...

Page 277: ...stall the slot cover of slot 1 or slot 2 as described in section Installing the slot cover slot 1 3 on page 161 Ê Install the riser module 1 or the riser module2 as described in section Handling riser modules on page 58 14 3 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Enabling BitLocker functionality on page 83...

Page 278: ...onent on page 47 14 4 2 Removing the defective serial interface Ê Remove the serial interface as described in section Removing the serial interface on page 276 14 4 3 Installing the new serial interface Ê Install the serial interface as described in section Installing the serial interface on page 274 14 4 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 ...

Page 279: ...edges For further information please refer to chapter Important information on page 31 15 1 Basic information This section provides instructions for the system board and the following components CMOS memory volatile BIOS memory and the real time clock are powered by a lithium coin cell CMOS battery This cell lasts up to ten years depending on ambient temperature and use If the CMOS battery is depl...

Page 280: ...atteries into the trash can Lithium batteries must be disposed of in accordance with local regulations concerning special waste For further safety information please refer to section Environmental protection in the PRIMERGY RX200 S8 Operating Manual Ensure to insert the CMOS battery the with the positive pole facing up 15 2 1 Preliminary steps Ê Locating the defective server on page 43 Ê Shutting ...

Page 281: ...em board components in case of slipping If the CMOS battery cannot be ejected without the help of a tool it is recommended to use a tooth pick Ê Insert a new CMOS battery of the same type into the socket 3 and 4 15 2 3 Concluding steps Ê Dispose of the CMOS battery in accordance with local regulations concerning special waste Ê Reassembling on page 52 Ê Connecting the server to the mains on page 5...

Page 282: ...ing BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the riser module 3 on page 60 15 3 1 2 Installing the UFM Figure 215 UFM installation kit Field Replaceable Unit FRU Hardware 5 minutes Software 5 minutes Tools tool less 1 USB Flash Module UFM 3 UFM spacer 2 UFM n...

Page 283: ... to the system board The UFM spacer must click into the hole on the system board 15 3 1 3 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Enabling SVOM boot watchdog functionality on page 78 Ê Switching on the server on page 58 Ê Enabling BitLocker functionality on page 83 ...

Page 284: ...The server should now boot from the Recovery Tool CD Ê Follow the on screen instructions 15 3 2 Removing the UFM 15 3 2 1 Preliminary steps Ê Disabling SVOM boot watchdog functionality on page 64 Ê Disabling BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the riser ...

Page 285: ...move the UFM 2 Figure 219 Remaining UFM spacer The UFM spacer remains on the system board V CAUTION UFM contains customer information e g IP address License etc After replacing the UFM you must pass the defective UFM to the customer and ask for disposal If the disposal of the defective UFM is requested by the customer you break it according to the following procedure and dispose it ...

Page 286: ...pliers and a combination pliers to break the UFM in half as shown in the figure 15 3 2 3 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Enabling SVOM boot watchdog functionality on page 78 Ê Switching on the server on page 58 Ê Enabling BitLocker functionality on page 83 ...

Page 287: ... Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the riser module 3 on page 60 15 3 3 2 Removing the defective UFM Ê Remove the UFM as described in section Removing the UFM on page 285 Ê The UFM spacer remains on the system board Field Replaceable Unit FRU Hardware 5 minutes Software 5 minutes Tools ...

Page 288: ...UFM spacer Ê Remove the nylon screw from the UFM 1 Ê Remove the UFM spacer 2 Figure 223 Installing the UFM Ê Connect the UFM to the system board and the remaining UFM spacer 1 Ê Fasten the UFM to the UFM spacer with the nylon screw 2 15 3 3 4 Concluding steps Ê Installing the riser module 3 on page 61 Ê Reassembling on page 52 0 ...

Page 289: ... the server Ê Right after switching on the server insert the Recovery Tool CD into the DVD drive and close the drive tray Ê The server should now boot from the Recovery Tool CD Ê Follow the on screen instructions 15 4 Trusted Platform Module TPM 15 4 1 Installing the TPM 15 4 1 1 Preliminary steps Ê Disabling BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting ...

Page 290: ...page 47 Ê Removing the riser module 1 on page 58 15 4 1 2 Installing the TPM Figure 224 TPM installation kit Figure 225 Position on the system board 1 TPM Trusted Platform Module 3 Special screw for TPM 2 TPM spacer I The black TPM spacer is not used in this server 4 TPM bit insert for TPM special screw 0 1 2 ...

Page 291: ...board and components Figure 226 Inserting the TPM spacer on the system board Ê Insert the TPM spacer into the hole on the system board Figure 227 TPM bit insert Ê Attach the TPM bit insert or TPM module fixing tool Japanese market to a bit screw driver ...

Page 292: ...ghtly touches the TPM torque value of 0 6 Nm 15 4 1 3 Concluding steps Ê Installing the riser module 1 on page 59 Ê Reassembling on page 52 Ê Disconnecting the server from the mains on page 47 Ê Enable TPM in the system board BIOS Proceed as follows Ê Switch on or restart your server Ê As soon as the startup screen appears press the F2 function key to enter the BIOS Ê Select the Advanced menu Ê Se...

Page 293: ... be restored re saved by the customer After installing a new system board the TPM must be enabled You may not clear the TPM data If the contact persons DO NOT have a backup copy available inform them that removing the TPM will cause to lose all data 15 4 2 1 Preliminary steps Before removing the TPM perform the following steps Ê Before removing the TPM board it is necessary to remove BitLocker pro...

Page 294: ...l of the information stored on that computer is decrypted For further information on how to disable BitLocker drive encryption please refer to the Microsoft Knowledge Base Fujitsu service partners will find additional information also available in Japanese on the Fujitsu Extranet web pages Ê Disable TPM in the system board BIOS Proceed as follows Ê Switch on or restart your server Ê As soon as the...

Page 295: ...efully loosen the TPM screw using a thin slotted screw driver e g watchmaker s screw driver or the dedicated TPM screw driver Japanese market 2 V CAUTION Ensure to turn the screw clockwise in order to remove it Slowly and carefully increase the pressure on the screw until it begins to turn The effort when loosing the screw should be as low as possible Otherwise the thin metal bar may break renderi...

Page 296: ...ss together the hooks on the TPM spacer 1 see close up and remove it from the system board 2 I If the TPM is to be replaced the TPM spacer may remain on the system board 15 4 2 3 Concluding steps Ê Installing the new system board on page 309 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 0 ...

Page 297: ... them that replacing the TPM board will cause to lose all data 15 4 3 1 Preliminary steps Ê Locating the defective server on page 43 Ê Disabling BitLocker functionality on page 63 Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Field Replaceable Unit FRU Hardware 30 minutes Tools Removing the system board Phill...

Page 298: ...he TPM spacer is already present on the system board Ê Install the TPM as described in section Installing the TPM on page 290 15 4 3 4 Concluding steps Ê Reinstall the system board as described in section Installing the new system board on page 309 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Enabling BitLocker functionality on pa...

Page 299: ...ey 15 5 1 1 Preliminary steps Ê Shutting down the server on page 46 Ê Disconnecting the server from the mains on page 47 Ê Getting access to the component on page 47 Ê Removing the air duct on page 62 15 5 1 2 Installing the onboard SAS enabling key Figure 232 Onboard SAS enabling key Upgrade and Repair Unit URU Hardware 5 minutes Tools tool less ...

Page 300: ...he onboard SAS enabling key Ê Connect the onboard SAS enabling key to the connector SKU KEY on the system board 15 5 1 3 Concluding steps Ê Installing the air duct on page 62 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Switching on the server on page 58 Ê Verifying system information backup restore on page 73 ...

Page 301: ...ge 47 Ê Getting access to the component on page 47 Ê Removing the air duct on page 62 15 5 2 2 Removing the onboard SAS enabling key Figure 235 Removing the onboard SAS enabling key Ê Firmly pull up on the release lash until the onboard SAS enabling key pops out of its connector 15 5 2 3 Concluding steps Ê Installing the air duct on page 62 Ê Reassembling on page 52 Upgrade and Repair Unit URU Har...

Page 302: ... page 47 Ê Getting access to the component on page 47 Ê Removing the air duct on page 62 15 5 3 2 Replacing the onboard SAS enabling key Ê Remove the defective onboard SAS enabling key as described in section Removing the onboard SAS enabling key on page 301 Ê Install the new onboard SAS enabling key as described in section Installing the onboard SAS enabling key on page 299 15 5 3 3 Concluding st...

Page 303: ...ard For a detailed description please refer to section Replacing the TPM on page 297 The TPM is activated in the system BIOS V CAUTION Before replacing the system board ask the customer whether TPM functionality is used Field Replaceable Unit FRU Hardware 40 minutes Software 10 minutes Tools Replacing the system board Phillips PH2 No 2 screw driver Magnifying glass for inspecting processor socket ...

Page 304: ...l housing type serial number and manufacturing data To avoid the loss of non default settings when replacing the system board a backup copy of important system configuration data is automatically stored from the system board NVRAM to the Chassis ID EPROM After replacing the system board the backup data is restored from the front panel board to the new system board V CAUTION For that reason the fro...

Page 305: ... reinstall the memory modules in the slot they were located before the replacement Ê Remove all heat sinks see section Removing the heat sink on page 223 Ê Remove all expansion cards see section Expansion cards and riser cards on page 152 I Before removing the expansion cards take a note on the installation slot number for each card Make sure that you reinstall the card in the slot it was located ...

Page 306: ... 15 6 2 Removing the defective system board Ê Disconnect all cables from the system board Figure 236 Removing the fan cage Ê Remove the four screws 1 Ê Push the fan cage somewhat in direction of the arrow 2 to disengage the hooks see close up Ê Remove the fan cage upward 3 ...

Page 307: ...enance Manual 307 System board and components Figure 237 Removing the distance holder Ê Remove the distance holder from the system board see circle Figure 238 Position of the screws Ê Remove the nine screws from the system board ...

Page 308: ...oard come under tension and increase the risk of damage and malfunction Don t damage the EMI springs which are essential to comply with applicable EMC regulations and satisfy cooling requirements and fire protection measures Ê Place the removed and the new system board on an antistatic surface Ê Remove the TPM as described in section Removing the TPM on page 293 Ê Remove the processor as described...

Page 309: ...ettings on page 334 Ê Insert the system board by holding it at a slight angle Slide the connectors into the connector panel see figure 239 on page 308 Ê Lower the system board carefully into the chassis Ê Adjust the system board If necessary adjust the position of the system board with a gentle twisting motion I When the system board is in the right position the centre rings engage with the holes ...

Page 310: ... engage the hooks see close up Ê Fasten fan cage with the four screws 3 Ê Reconnect all cables to the system board Two power cables of power supply Front panel cable Power cable for HDD backplane SATA cables for HDD backplane if applicable SATA cable for ODD if applicable Front VGA cable if applicable I2C cable HDD monitoring if applicable For the cable plan see section Cabling on page 314 ...

Page 311: ...ge 231 Ê Installing the new front LAN card on page 262 if applicable Ê Install all expansion cards see section Expansion cards and riser cards on page 152 I Make sure that you reinstall each card in the slots it was located before the replacement Ê Installing the air duct on page 62 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 57 Ê Connect all external cables Ê Updating o...

Page 312: ...nfigure your network settings in the operation system according to the original configuration of the replaced controller expansion card or onboard I Configuration of network settings should be performed by the customer For further information please refer to section Note on network settings recovery on page 304 Ê If applicable restore LAN teaming configurations as described in section After replac...

Page 313: ...CABLE System board to backplane 6 A3C40137881 SATA ODD CABLE System board and 4x BPL to ODD cage 7 T26139 Y3994 V101 VGA cable System board to front VGA 8 T26139 Y3987 V2 iBBU cable 550 mm iBBU to MegaRAID SAS 9280 8e controller 9 T26139 Y3987 V3 iBBU cable 16 cm iBBU to RAID card D2616 10 T26139 Y4032 V3 FBU cable 17 cm FBU to RAID card D3116 11 T26139 Y4032 V2 FBU cable 47 cm FBU to MegaRAID SAS...

Page 314: ...Upgrade and Maintenance Manual RX200 S8 Cables 16 2 Cabling Figure 241 Basic cabling Figure 242 Basic cabling Front VGA LAN Front panel PSU 1 PSU 2 P D B 1 Front panel PSU 1 PSU 2 P D B 1 Front VGA LAN 7 14 ...

Page 315: ...intenance Manual 315 Cables Figure 243 Basic cabling ODD 4xHDD onboard Figure 244 Basic cabling ODD 4xHDD RAID card D2616 Front panel PSU 1 PSU 2 P D B 1 2 5 3 ODD 6 Front panel PSU 1 PSU 2 P D B 1 5 3 ODD 6 2 RAID card D2616 ...

Page 316: ... Cables Figure 245 Basic cabling ODD 4xHDD RAID card D2616 iBBU Figure 246 Basic cabling 8xHDD RAID card D2616 iBBU Front panel PSU 1 PSU 2 P D B 1 5 3 ODD 6 iBBU 9 2 RAID card D2616 Front panel PSU 1 PSU 2 P D B 1 5 3 2 iBBU 9 4 RAID card D2616 ...

Page 317: ...asic cabling 8xHDD RAID card D2616 MegaRAID card 9280 8e iBBU Figure 248 Basic cabling 8xHDD RAID card D3116 FBU Front panel PSU 1 PSU 2 P D B 1 5 3 2 iBBU 4 8 RAID card D2616 MegaRAID card SAS 9280 8e Front panel PSU 1 PSU 2 P D B 1 5 3 2 FBU 10 4 RAID card D3116 ...

Page 318: ...RAID card D3116 MegaRAID card 9285CV 8e FBU Figure 250 Basic cabling MegaRAID card 9285CV 8e in slot 2 Front panel PSU 1 PSU 2 P D B 1 5 3 2 FBU 4 11 RAID card D3116 MegaRAID card SAS 9285CV 8e Front panel PSU 1 PSU 2 P D B 1 5 3 2 FBU 4 11 RAID card D3116 MegaRAID card SAS 9285CV 8e ...

Page 319: ...ade and Maintenance Manual 319 Cables Figure 251 Basic cabling RAID card D3116 MegaRAID card 9285CV 8e FBU D2755 Front panel PSU 1 PSU 2 P D B 1 5 3 2 FBU 4 11 D2755 13 12 RAID card D3116 MegaRAID card SAS 9285CV 8e ...

Page 320: ...320 Upgrade and Maintenance Manual RX200 S8 Cables ...

Page 321: ... 2 5 inch HDDs Figure 253 Front side 8x 2 5 inch HDDs Pos Component 1 4x 2 5 inch hard disk drives dummy modules 2 Front VGA LAN module option 3 ID card 4 ODD option dummy cover 5 Front panel and indicators Pos Component 1 8x 2 5 inch hard disk drives dummy modules 2 Front VGA LAN module 3 ID card 4 Front panel and indicators ...

Page 322: ...l RX200 S8 Appendix 17 1 2 Server rear Figure 254 Rear side I PCIe slot 4 is located inside the housing Pos Component 1 Up to 2 power supply units dummy cover 2 PCIe slot 3 3 PCIe slot 2 option 4 PCIe slot 1 5 Connectors and indicators ...

Page 323: ...e 4x 2 5 inch HDDs Pos Component 1 Up to 2 power supply units 2 Riser module 1 3 Riser module 2 4 Riser module 3 5 CPU 1 6 Main memory CPU 1 7 CPU 2 8 Main memory CPU 2 9 Fan modules 10 4x 2 5 inch hard disk drives dummy modules 11 Top side front VGA LAN module option Bottom side ODD option dummy cover ...

Page 324: ...example 8x 2 5 inch HDDs Pos Component 1 Up to 2 power supply units 2 Riser module 1 3 Riser module 2 4 Riser module 3 5 CPU 1 6 Main memory CPU 1 7 CPU 2 8 Main memory CPU 2 9 Fan modules 10 8x 2 5 inch hard disk drives dummy modules 11 Top side front VGA LAN module option ...

Page 325: ...MM 1E CPU 2 DIMM 2E CPU 2 DIMM 3E CPU 2 DIMM 1F CPU 2 DIMM 1G CPU 2 DIMM 2G CPU 2 DIMM 3H CPU 2 DIMM 2H CPU 2 DIMM 1H CPU 2 DIMM 3G PCH CPU 1 DIMM 1A CPU 1 DIMM 2A CPU 1 DIMM 3B CPU 1 DIMM 2B CPU 1 DIMM 1B CPU 1 DIMM 3A CPU 1 DIMM 3D CPU 1 DIMM 2D CPU 1 DIMM 1C CPU 1 DIMM 2C CPU 1 DIMM 3C CPU 1 DIMM 1D 1 CN101 J9 FAN 11 12 SYS SATA 1 SAS 1 SMB SAS Front Panel Front VGA PWR 1 BP PWR Front LAN M CPU...

Page 326: ...d 12 9 SAS 1 SATA connector for optical drive 10 BP PWR Power connector for SAS SATA backplane 11 FRONT LAN M Connector for optional front LAN card 12 SAS SMB LED signaling connector for SAS SATA backplane 13 FAN 9 10 SYS Power connector for system fans 9 and 10 14 FAN 7 8 SYS Power connector for system fans 7 and 8 15 FAN 5 6 SYS Power connector for system fans 5 and 6 16 FAN 3 4 SYS Power connec...

Page 327: ...S TPM LAN CTRL F I G G H Battery VGA USB 2 USB 3 Shared LAN LAN 2 Management LAN Slot riser card slot 2 and 3 CPU 2 DIMM 3F CPU 2 DIMM 2F CPU 2 DIMM 1E CPU 2 DIMM 2E CPU 2 DIMM 3E CPU 2 DIMM 1F CPU 2 DIMM 1G CPU 2 DIMM 2G CPU 2 DIMM 3H CPU 2 DIMM 2H CPU 2 DIMM 1H CPU 2 DIMM 3G H PCH H CPU 1 DIMM 1A CPU 1 DIMM 2A CPU 1 DIMM 3B CPU 1 DIMM 2B CPU 1 DIMM 1B CPU 1 DIMM 3A H CPU 1 DIMM 3D CPU 1 DIMM 2D ...

Page 328: ...CSS component orange on indicates a prefailure non CSS component orange flashing indicates a failure of a non CSS component Reasons for a failure may be over temperature measured by one of the sensors sensor is defective CPU error software detected an error F Controller off PCI card okay orange on PCI card failure PCI card installed on riser card G CPU off CPU okay orange on CPU failure H Memory m...

Page 329: ...s No Description 1 Shared LAN connector for WOL PXE iSCSI function LAN1 2 Standard LAN connector LAN2 3 Management LAN connector for iRMC S4 server management function 4 Global error indicator orange CSS indicator yellow ID indicator blue description see preceding section 5 Video connector VGA 6 3x USB connectors ...

Page 330: ... LAN connection established off no LAN connection green flashing data transfer in progress 3 Global error indicator off no critical event non CSS component orange on prefailure detected non CSS component orange flashing non CSS component failure CSS indicator off no critical event CSS component yellow on prefailure detected CSS component yellow flashing CSS component failure ID indicator blue on s...

Page 331: ... green when the server is switched on and functioning properly Flashes orange when a predictable error has been detected but the power supply unit is still running Lights up orange if no mains voltage is present or the power supply unit has failed 450 W power supply unit Flashes green when the server is switched off but mains voltage is present standby mode Lights up green when the server is switc...

Page 332: ...eplace the part Pos Indicator Status Description 1 HDD SSD error indicator orange on HDD SSD SAS SATA backplane or RAID controller failure detected 2 PSU error indicator orange on Hot plug PSU failure detected I Only available in redundant PSU configurations 3 Temperature error indicator orange on Operating temperature levels above permitted limits 4 CPU error indicator orange on CPU prefailure ev...

Page 333: ...ical event CSS component yellow on prefailure detected CSS component yellow flashing CSS component failure 9 Global error indicator off no critical event non CSS component orange on prefailure detected non CSS component orange flashing non CSS component failure 10 HDD SSD activity indicator green flashing data access in progress 11 Power on indicator green on server is switched on and running oran...

Page 334: ...PU 1 DIMM 1A CPU 1 DIMM 2A CPU 1 DIMM 3B CPU 1 DIMM 2B CPU 1 DIMM 1B CPU 1 DIMM 3A CPU 1 DIMM 3D CPU 1 DIMM 2D CPU 1 DIMM 1C CPU 1 DIMM 2C CPU 1 DIMM 3C CPU 1 DIMM 1D 1 CN101 J9 FAN 11 12 SYS SATA 1 SAS 1 SMB SAS Front Panel Front VGA PWR 1 BP PWR Front LAN M CPU 2 CPU 1 FAN 9 10 SYS FAN 7 8 SYS FAN 5 6 SYS FAN 3 4 SYS FAN 1 2 SYS USB 1 Slot riser card slot 1 Slot riser card slot 4 Slot 3 Slot 2 U...

Page 335: ... Description CN101 3 5 position Normal operation default Password Clear and Recovery BIOS disabled 1 2 position Password Clear enabled 5 6 position Recovery BIOS enabled J9 1 2 position Normal operation default 2 3 position Clear CMOS data and restore default settings Field Replaceable Units FRU Component Notes System board no TPM UFM or expansion cards installed CPU with CPU heat sink installed i...

Page 336: ...se and display to the server Ê Switching on the server on page 58 V CAUTION Since the fan module is not included in the minimum startup configuration the server must be shut down immediately after the diagnostic process is complete POST phase has been passed The minimum startup configuration must be used exclusively for diagnostic purposes by maintenance personnel never in daily operation Cable No...

Reviews: