17.4 Minimum startup configuration
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Jumper
Status
Description
CN101
3-5 position: Normal operation (default)
Password Clear and Recovery BIOS
disabled
1-2 position: Password Clear enabled
5-6 position: Recovery BIOS enabled
J9
1-2 position: Normal operation (default)
2-3 position: Clear CMOS data and restore
default settings
Field Replaceable Units (FRU)
Component
Notes
System board
no TPM, UFM or expansion cards installed
CPU with CPU heat sink
installed in socket CPU 1
1 memory module
installed in slot DIMM 1A
Front panel module
Power supply unit
installed in bay 1
Table 6: Minimum startup configuration - components
Summary of Contents for PRIMERGY RX200 S8
Page 30: ...30 Upgrade and Maintenance Manual RX200 S8 Before you start ...
Page 42: ...42 Upgrade and Maintenance Manual RX200 S8 Important information ...
Page 106: ...106 Upgrade and Maintenance Manual RX200 S8 Power supply ...
Page 130: ...130 Upgrade and Maintenance Manual RX200 S8 Hard disk drives solid state drives ...
Page 194: ...194 Upgrade and Maintenance Manual RX200 S8 Expansion cards and backup units ...
Page 210: ...210 Upgrade and Maintenance Manual RX200 S8 Main memory ...
Page 234: ...234 Upgrade and Maintenance Manual RX200 S8 Processors ...
Page 244: ...244 Upgrade and Maintenance Manual RX200 S8 Optical disk drive ...
Page 320: ...320 Upgrade and Maintenance Manual RX200 S8 Cables ...