CX400 S1
Upgrade and Maintenance Manual
93
Power supply
6.5.2
Replacing the defective bottom PDB
Note on system information
The bottom PDB contains the Chassis ID EPROM that contains system
information like server name and model, housing type, serial number and
manufacturing data.
6.5.2.1
Required tools
●
Preliminary and concluding steps:
– Phillips PH2 / (+) No. 2 screw driver
●
Main steps:
– Phillips PH2 / (+) No. 2 screw driver
6.5.2.2
Preliminary steps
Perform the following procedures:
Ê
"Shutting down the server node" on page 41
Ê
"Removing the server enclosure out of the rack" on page 43
V
CAUTION!
For ALL service tasks, remove the CX400 S1 server enclosure out of
the rack and put it on a separate desk!
It is not allowed to draw the CX400 S1server enclosure partially out
of the rack.
Ê
"Removing the server node from the server enclosure" on page 48
Field Replaceable Units (FRU)
Average hardware task duration: 25 minutes
Average software task duration: 5 minutes
Summary of Contents for PRIMERGY CX400 S1
Page 12: ...12 Bearbeitungsstand Bestellnummer Content ...
Page 14: ...14 Upgrade and Maintenance Manual CX400 S1 Version history ...
Page 18: ...18 Upgrade and Maintenance Manual CX400 S1 Introduction ...
Page 76: ...76 Upgrade and Maintenance Manual CX400 S1 Basic hardware procedures ...
Page 132: ...132 Upgrade and Maintenance Manual CX400 S1 Hard disk drives solid state drives ...
Page 196: ...196 Upgrade and Maintenance Manual CX400 S1 Cabling 12 3 Cabling Figure 147 2 5 inch chassis ...
Page 197: ...CX400 S1 Upgrade and Maintenance Manual 197 Cabling Figure 148 3 5 inch chassis ...
Page 198: ...198 Upgrade and Maintenance Manual CX400 S1 Cabling ...