1. Przeznaczenie:

 

 

Obudowy 

AWO 005PU

 zaprojektowane zostały jako elementy systemów SSWiN, KD, itp.  

Przeznaczone są do montażu (w zależności od modelu):  

 

płyty centrali alarmowej i opcjonalnie dodatkowych modułów 

 

kontrolera systemu KD i modułów dodatkowych 

 

nadajnika radiowego lub GSM, opcjonalnie modułu zasilacza buforowego  

 

innych dedykowanych urządzeń 

 

do obudowy można zamontować transformator typu: TRP20, TRP40, TRZ20, TRZ40, EI20, EI40. 

 
2. Montaż:

  

 

Obudowa przeznaczona jest do montażu przez wykwalifikowanego instalatora, posiadającego odpowiednie          

(wymagane i konieczne dla danego kraju) zezwolenia i uprawnienia do ingerencji w instalacje niskonapięciowe. 

Obudowa (+PCB) powinna być montowana w pomieszczeniach zamkniętych, o normalnej wilgotności powietrza 

(RH=90% maks. bez kondensacji) i temperaturze z zakresu -10°C do +40°C. 

 

 

 
 
 
 
 
 
 
1. Destination: 

EN 

 

The 

AWO 005PU

 metal casings are designed as components (supplying) in intruders alarms, access control 

systems, security systems etc. There are intended for installation: 

 

control panel optional with supplementary modules 

 

access control controllers with optional modules  

 

radio or GSM transmitter with optional module PSU 

 

other dedicated devices, components etc. 

 

transformers which can be mounted in the casing TRP20, TRP40, TRZ20, TRZ40, EI20, EI40. 

 
2. Installation:  

 

 
The metal casing must be installed by a qualified installer, holding the relevant certificates, required and 

necessary in the particular country for connecting (interfering with) the 230V AC systems and low-voltage installations.  

The casing (+PCB) should be installed indoors, where the air humidity is normal (RH=90% max. without 

condensation) and temperature in the range of -10°C to +40°C. 

 

 

 
 
 
 

Summary of Contents for AWO 005PU

Page 1: ... ingerencji w instalacje niskonapięciowe Obudowa PCB powinna być montowana w pomieszczeniach zamkniętych o normalnej wilgotności powietrza RH 90 maks bez kondensacji i temperaturze z zakresu 10 C do 40 C 1 Destination EN The AWO 005PU metal casings are designed as components supplying in intruders alarms access control systems security systems etc There are intended for installation control panel ...

Page 2: ... lub U2 or I1 lub I2 or F t AWT060 EI20 16 18 20VA 230V AC 0 12A 16V lub 18V or 1 2A lub1 0A or T 200mA 250V 130o C AWT070 EI40 16 18 40VA 230V AC 0 20A 16V lub 18V or 2 2A lub2 0A or T 315mA 250V 130o C AWT050 TRP 20 16 18 PC ABS UL94 V 0 IP30 20VA 230V AC 0 12A 16V lub 18V or 1 2A lub 1 0A or T 200mA 250V 130o C AWT053 TRP 20 12 14 PC ABS UL94 V 0 IP30 20VA 230V AC 0 12A 12V lub 14V or 1 6A lub ...

Page 3: ...a zamontować w tej obudowie panels which can be mounted in the casing SATEL 1 CA 4V1 CA5 CA6 CA10 VERSA 5 10 15 INTEGRA 24 32 Moduły modules 1 CA64 PP EPS ADR O R O ROC O OC OPS OC OPS R OPS ROC VGM 16 SR PTSA ACC KP PS PL EN ...

Page 4: ...wych i detalicznych tego sprzętu oraz gminne jednostki organizacyjne prowadzące działalność w zakresie odbierania odpadów Prawidłowa realizacja tych obowiązków ma znaczenie zwłaszcza w przypadku gdy w zużytym sprzęcie znajdują się składniki niebezpieczne które mają negatywny wpływ na środowisko i zdrowie ludzi WEEE MARK The waste electric and electronic products do not mix with general household w...

Reviews: