Important information
●
If the device is brought in from a cold environment, condensation may form
both inside and on the outside of the device.
Wait until the device has acclimatized to room temperature and is absolutely
dry before starting it up. Material damage may be caused to the device if this
requirement is not observed.
●
Transport the device only in the original packaging or in packaging that
protects it from knocks and jolts.
For the Japanese market, transporting the device in its original packaging
does not apply.
Installation and operation
●
This unit should not be operated in ambient temperatures above 35 °C.
●
If the unit is integrated into an installation that draws power from an industrial
power supply network with an IEC309 connector, the power supply's fuse
protection must comply with the requirements for non-industrial power
supply networks for type A connectors.
●
The unit automatically adjusts itself to a mains voltage in a range of 200 VAC
to 240 VAC. (For the Japanese market there are two PSUs available: PSU
for 100V is set to a mains voltage in the range of 100V - 240V). Ensure that
the local mains voltage lies within these limits.
●
This device must only be connected to properly grounded power outlets or
connected to the grounded rack internal power distribution system with
tested and approved power cords.
●
Ensure that the device is connected to a properly grounded power outlet
close to the device.
●
Ensure that the power sockets on the device and the properly grounded
power outlets are easily accessible.
●
The On/Off button or the main power switch (if present) does not isolate the
device from the mains power supply. In case of repair or servicing
disconnect the device completely from the mains power supply, unplug all
power plugs from the properly grounded power outlets.
●
Always connect the server and the attached peripherals to the same power
circuit. Otherwise you run the risk of losing data if, for example, the server is
still running but a peripheral device (e.g. memory subsystem) fails during a
power outage.
●
Data cables must be adequately shielded.
Summary of Contents for PRIMERGY CX400 S1
Page 12: ...12 Bearbeitungsstand Bestellnummer Content ...
Page 14: ...14 Upgrade and Maintenance Manual CX400 S1 Version history ...
Page 18: ...18 Upgrade and Maintenance Manual CX400 S1 Introduction ...
Page 76: ...76 Upgrade and Maintenance Manual CX400 S1 Basic hardware procedures ...
Page 132: ...132 Upgrade and Maintenance Manual CX400 S1 Hard disk drives solid state drives ...
Page 196: ...196 Upgrade and Maintenance Manual CX400 S1 Cabling 12 3 Cabling Figure 147 2 5 inch chassis ...
Page 197: ...CX400 S1 Upgrade and Maintenance Manual 197 Cabling Figure 148 3 5 inch chassis ...
Page 198: ...198 Upgrade and Maintenance Manual CX400 S1 Cabling ...