CX272 S1
Upgrade and Maintenance Manual
77
Basic software procedures
5.2
Completing the maintenance task
5.2.1
Updating or recovering the system board BIOS and
BMC
After replacing the system board, it is essential to upgrade the BIOS and BMC
to the latest version. The latest BIOS and BMC versions are available from the
Fujitsu support internet pages at:
http://ts.fujitsu.com/support/
(EMEA market)
http://jp.fujitsu.com/platform/server/primergy/downloads/
(Japanese market)
I
Fujitsu does not assume responsibility for any damage done to the
server or for the loss of any data resulting from BIOS updates.
5.2.1.1
Updating or recovering the system board BIOS
Flash BIOS Update with a USB stick
Ê
Make sure, that you have a bootable USB stick.
I
If your USB stick is not bootable proceed as follows:
Ê
The USB stick is inserted in the USB port of the system that
downloads the USB image file.
Ê
Follow the instructions.
You need a USB stick on which the BIOS update files will be stored.
The data on the USB stick will be fully erased and overwritten.
Make sure, that all data are saved before.
Ê
Unzip the downloaded zip file from
CX272 S1 / D3306 Flash BIOS for
USB Image
.
Ê
Double-click the *.exe file in the unzipped files.
Ê
The USB image file is copied onto the USB stick according to the
instructions on the screen.
Ê
Boot the system from the inserted bootable USB stick.
Ê
Wait until the screen output appears.
Summary of Contents for PRIMERGY CX272 S1
Page 14: ...Upgrade and Maintenance Manual CX272 S1 Contents ...
Page 18: ...18 Upgrade and Maintenance Manual CX272 S1 Introduction ...
Page 92: ...92 Upgrade and Maintenance Manual CX272 S1 Basic software procedures ...
Page 156: ...156 Upgrade and Maintenance Manual CX272 S1 Main memory ...
Page 220: ...220 Upgrade and Maintenance Manual CX272 S1 System board and components ...
Page 234: ...234 Upgrade and Maintenance Manual CX272 S1 Appendix ...