CX2550 M1
Upgrade and Maintenance Manual
79
Basic software procedures
5.2.12 Resuming BitLocker functionality
If BitLocker Drive Encryption has been suspended for maintenance purposes
(see section
"Suspending BitLocker functionality" on page 53
), it has to be re-
enabled to complete the service task.
I
If BitLocker Drive Encryption has been suspended prior to replacing
components you won't be asked for a recovery key when rebooting the
server after the maintenance task. However, if BitLocker functionality has
not been suspended, Windows will enter recovery mode and ask you to
input recovery key for further booting.
Ê
In this case, ask the system administrator to enter the recovery key in
order to boot the operating system.
Ê
Ask the system administrator to enable the previously suspended BitLocker-
protection on the system volume, using the
BitLocker Drive Encryption
control
panel item:
For Windows Server 2008:
Ê
Open BitLocker Drive Encryption by clicking the
Start
button, clicking
Control Panel
, clicking
Security
, and then clicking
BitLocker Drive
Encryption
.
Ê
Select the system volume, and click
Turn On BitLocker
.
For Windows Server 2008 R2 and above:
Ê
Open BitLocker Drive Encryption by clicking the
Start
button, clicking
Control Panel
, clicking
System and Security
, and then clicking
BitLocker
Drive Encryption
.
Ê
Select the system volume, and click
Resume Protection
.
I
For further information on how to resume BitLocker drive
encryption, please refer to the Microsoft TechNet library at
http://technet.microsoft.com/library/cc731549.aspx.
Fujitsu service partners will find additional information (also available
in Japanese) on the Fujitsu Extranet web pages.
Summary of Contents for PRIMERGY CX2550 M1
Page 14: ...Upgrade and Maintenance Manual CX2550 M1 Contents ...
Page 52: ...52 Upgrade and Maintenance Manual CX2550 M1 Basic hardware procedures ...
Page 90: ...90 Upgrade and Maintenance Manual CX2550 M1 Basic software procedures ...
Page 204: ...204 Upgrade and Maintenance Manual CX2550 M1 Liquid cooling ...
Page 210: ...210 Upgrade and Maintenance Manual CX2550 M1 Cabling ...
Page 222: ...222 Upgrade and Maintenance Manual CX2550 M1 Appendix ...