220
Upgrade and Maintenance Manual
CX2550 M1
Appendix
12.3 Minimum startup configuration
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Ê
Shut down the server as described in section
"Shutting down the server
node" on page 39
.
Ê
Take the system down to its minimum startup configuration.
Ê
Connect a keyboard, mouse and display to the server.
Ê
Switch on the server as described in section
"Controls and indicators on the
server node" on page 51
.
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
Field Replaceable Units (FRU)
Component
Notes and reference
System board
no TPM or expansion cards installed
CPU1 and CPU2 with CPU
heat sink
2 memory modules
installed in slot A1 or E1, see section
"Memory
sequence" on page 118
2 Power supply units
Table 10: Minimum startup configuration - components
Cable
Notes and reference
2 SATA cables
Table 11: Minimum startup configuration - cables
Summary of Contents for PRIMERGY CX2550 M1
Page 14: ...Upgrade and Maintenance Manual CX2550 M1 Contents ...
Page 52: ...52 Upgrade and Maintenance Manual CX2550 M1 Basic hardware procedures ...
Page 90: ...90 Upgrade and Maintenance Manual CX2550 M1 Basic software procedures ...
Page 204: ...204 Upgrade and Maintenance Manual CX2550 M1 Liquid cooling ...
Page 210: ...210 Upgrade and Maintenance Manual CX2550 M1 Cabling ...
Page 222: ...222 Upgrade and Maintenance Manual CX2550 M1 Appendix ...