3.1.1 Problems at power-on initialization (part 003/3)
Symptom
Cause
Response
A ROM or RAM
alarm is detected.
Replace and initialize
the driver board.
After the POWER lamp goes
on, simultaneous blinking of
all other lamps is not
performed but the PAPER
OUT lamp blinks.
Low-voltage alarm is
detected.
• Replace the power
supply.
• Replace the control
board, then initialize
the EEPROM.
After APTC initialization, the
PAPER OUT lamp blinks.
• APTCHPSW ASY
is defective.
• The APTC motor
is defective.
• APTCHPSW ASY
is not connected.
• The driver board
is defective.
• Replace the
APTCHPSW ASY.
• Replace the APTC
motor.
• Connect the
APTCHPSW ASY
cable properly.
• Replace the driver
board.
When the power is turned on
after the carriage is moved to
the center of the side frames,
the carriage moves smoothly
but hits the left or right side
frame.
A LRES alarm is
detected.
• LES detection is
poor.
• The carriage cable
is defective.
• The driver board
is defective.
• The carriage cable
is disconnected.
• Clean or replace the
carriage PC board.
• Replace the
carriage cable.
• Replace the driver
board.
• Connect the carriage
cable properly.
After APTC initialization,
the PAPER OUT
lamp flashes.
• The carriage does not
move.
• An abnormal sound is
made.
• Carriage movement is not
smooth.
Space alarm is
detected.
A. The SP motor
connector is
disconnected.
B. The SP motor is
defective.
C. The stay shaft is
rough.
D. The SP belt is
loose.
E. The control board is
defective.
A. Connect the
Connector correctly.
B. Replace the space
motor.
C. Clean or lubricate the
stay shaft.
D. Check the tension
pulley.
E. Replace the control
board, then initialize
the EEPROM.
4 The PAPER OUT lamp
blinks.
The PAPER OUT lamp
blinks immediately after the
HCPP starts operation.
• HCPPSW ASY is
defective.
• The HCPP motor
is defective.
• HCPPSW ASY is
not connected.
• The control board
is defective.
• Replace the
HCPPSW ASY.
• Replace the HCPP
motor.
• Connect the
HCPPSW ASY cable
properly.
• Replace and
initialize the control
board.