3-6. Water leaking
Forecast of cause
Erroneous installation
Drain hose failure
Diagnosis method when water leak occurs
Diagnosis method when water is spitting
out
•
Is main unit installed in stable condi-
tion?
•
Is main unit broken or deformed at the
time of transportation or maintenance?
Is the filter clogged?
•
Is drain hose connection loose?
•
Is there a trap in drain hose?
•
Is drain hose clogged?
Check gas pressure and cor-
rect it if there was a gas leak.
MPa
MPa
Is fan rotating?
End
End
3-6. →ater leaking
- (03-47) -
3. Troubleshooting without error code
TR
O
U
B
LESH
O
O
TI
N
G
TR
O
U
B
LESH
O
O
TI
N
G
Summary of Contents for GENERAL AOHG18KMTA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 03 11 SR_CH01_AS070EG_01 ...
Page 15: ...2 TECHNICAL DATA AND PARTS LIST 2022 03 11 SR_CH02_AS070EG_02 ...
Page 41: ...3 TROUBLESHOOTING 2022 03 25 SR_CH03_AS070EG_01 ...
Page 44: ......
Page 103: ...4 CONTROL AND FUNCTIONS 2022 03 25 SR_CH04_AS070EG_01 ...
Page 105: ...8 8 High temperature and high pressure release control heating mode 04 29 CONTENTS continued ...
Page 106: ......
Page 137: ...5 FILED WORKING 2022 03 25 SR_CH05_AS070EG_01 ...