Heating mode
F zone
19°C
E zone
5°C
D zone
0°C
C zone
B zone
A zone
-15°C
-25°C
Model name
Outdoor temperature zone
Limitation of compressor
frequency
AOHG18KMTA
A zone
25 rps
B zone
25 rps
C zone
17 rps
D zone
10 rps
E zone
1 rps
F zone
1 rps
AOHG24KMTA
A zone
31 rps
B zone
31 rps
C zone
21 rps
D zone
13 rps
E zone
1 rps
F zone
1 rps
1-5. Compressor frequency limitation by outdoor temperature