2-18. E: 63. Inverter error (Outdoor unit)
Indicator
Indoor unit
Operation indicator
6 time flash
Timer indicator
3 time flash
Economy indicator
Continuous flash
Error code
E: 63
Detective actuator Outdoor unit
Main PCB
Error information received from outdoor unit main PCB
Forecast of cause
External cause
Power supply to main PCB wiring disconnection or open
Main PCB failure
Check point 1. Turn the power on again?
Error displayed again?
Check point 2. Check the wiring
•
Connector and wiring connection state check.
•
Cable open check.
Check point 3. Replace main PCB
Replace outdoor unit main PCB.
End
Check point 1-2. Check external cause
•
Check if temporary voltage drop was not generated.
•
Check if momentary open was not generated.
•
Check if ground is connection correctly or there are no related cables near the power line.
End
2-18. E: 63. Inverter error (Outdoor unit)
- (03-23) -
2. Troubleshooting with error code
TR
O
U
B
LESH
O
O
TI
N
G
TR
O
U
B
LESH
O
O
TI
N
G
Summary of Contents for GENERAL AOHG18KMTA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 03 11 SR_CH01_AS070EG_01 ...
Page 15: ...2 TECHNICAL DATA AND PARTS LIST 2022 03 11 SR_CH02_AS070EG_02 ...
Page 41: ...3 TROUBLESHOOTING 2022 03 25 SR_CH03_AS070EG_01 ...
Page 44: ......
Page 103: ...4 CONTROL AND FUNCTIONS 2022 03 25 SR_CH04_AS070EG_01 ...
Page 105: ...8 8 High temperature and high pressure release control heating mode 04 29 CONTENTS continued ...
Page 106: ......
Page 137: ...5 FILED WORKING 2022 03 25 SR_CH05_AS070EG_01 ...