FibreCAT TXF
Operating Manual
41
5
Troubleshooting
5.1
Backup subsystem cannot be switched on
Ê
Check the position of the power switch and, if necessary, move the switch to
the "Remote" or "On" position (see also
“Power switch” on page 40
).
Ê
Check the connections to the server and the mains connection.
Ê
Boot the system unit again.
5.2
SCSI devices are not detected
If the backup subsystem is switched on late (e.g. by plugging in the power
cable), the SCSI devices may not be detected when the system unit is booted.
I
The setting „remote“ can avoid that the system is switched on too late
Ê
Check the mains connection.
Ê
Reboot the system unit.
5.3
Incorrect SCSI ID
The backup device does not respond with demanded SCSI ID, or there is an
address conflict on the SCSI bus:
Ê
Check the address jumper of the backup device involved. Refer to the
documentation for the backup device for help.
The address jumpers of most backup devices are located on the rear of the
device.
Ê
Set the SCSI ID.
Summary of Contents for FibreCAT TXF
Page 1: ...FibreCAT TXF Backup Subsystem Operating Manual Edition November ...
Page 10: ......
Page 18: ......
Page 48: ......
Page 54: ......