ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED
P3AM-4842-12ENZ0
183
Appendix C
Event (SNMP Trap) Display When Using
ServerView Operation Manager
This appendix describes the display contents of events (SNMP Traps) that are notified to the SNMP manager
(monitoring server) when using the server management software "SeverView Operation Manager" for
monitoring the ETERNUS DX Disk storage system.
•
This appendix describes the display contents of events (SNMP Traps) when using the MIB definition file
for ServerView monitoring that is downloaded from the ETERNUS DX Disk storage system.
•
For detailed information about ServerView Operation Manager, refer to the ServerView Operation
Manager manuals.
Display contents of the ServerView Operation Manager
SNMP Trap type
Alarm type
(--#TYPE)
Severity
(--#SEVERITY)
Details (--#SUMMARY)
specific
trap
No.
Meaning
variable-bindings (*1) for %s, %x
Item fault
CRITICAL
Item fault event from
%s
, id:
%x
, message:
%s
2
A component
has failed or
degraded
%s
: fjdarySspMachineId
%x
: fjdaryTrapItemId
%s
: fjdaryTrapMessage
Item
warning
MAJOR
Item warning event from
%s
, id:
%x
[
%x
],
message:
%s
5
A component
requiring
preventive
maintenance is
detected
%s
: fjdarySspMachineId
%x
: fjdaryTrapItemId
%x
: fjdaryTrapWarningInfo
%s
: fjdaryTrapMessage
Sensor
status
changed
CRITICAL
Sensor status changed event from
%s
, id:
%x
[
%x
], message:
%s
6
Temperature
error is detected
%s
: fjdarySspMachineId
%x
: fjdaryTrapItemId
%x
: fjdaryTrapSensorInfo
%s
: fjdaryTrapMessage
Maintenance
required
CRITICAL
Maintenance required event from
%s
, id:
%x
,
message:
%s
7
An event
requiring
maintenance or
preventive
maintenance is
detected
%s
: fjdarySspMachineId
%x
: fjdaryTrapMaintenanceInfo
%s
: fjdaryTrapMessage
Information
event (*2)
INFORMATIONAL
Information event from
%s
, message: %s
9
An information-
level event is
detected
%s
: fjdarySspMachineId
%s