Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED
P3AM-4842-12ENZ0
142
*1: This row indicates TrapWarningInfo for Trap No. 5 and TrapSensorInfo for Trap No. 6.
J C1
MM
0000
(When
MM
is
40 – 7F)
5
0100
MM
00
0
CA Slot#
S
-
V
(
zz
) (on CM#
m
) Reboot
<
pppppppppppp ssssssssss rrrrr
>
These messages are
notified when "Parts
Warning" is enabled
for Warning Level in
the event notification
setting.
They are not notified
during maintenance
operations.
CA is rebooted.
MM
: CA module ID (40 – 7F)
S
: CA slot number (0 – 1)
V
: Device number (0 – 1)
zz
: CA type
m
: CM number (0 – 1)
pp...
: Component number
ss...
: Serial number
rr...
: Version
J C190
uu
0
n
5
9000
uu
0
n
0
IOM6 DE#
uu
/IOM#
n
Reboot <
pppppppppppp
ssssssssss rrrrr
>
IOM is rebooted.
SS
: Component subtype
uu
: DE-ID ("00" for a controller enclosure)
n
: IOM number (0 – 1)
pp...
: Component number
ss...
: Serial number
rr...
: Version
J C3
SSMM
00
5
0B00
MMnn
0
Controller Module#
m
(
zz
) Cache(MEM #
x
GB)
Slot#
nn
Correctable Error <
pppppppppppppppppp
ssssssssssss rrrrrr
>
Many correctable errors occurred in the CM
memory.
SS
: Component subtype
MM
: CM module ID (10 – 11)
m
: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
x
: Capacity of the cache memory (2 or 4)
nn
: Slot number of the cache memory (0 – 5)
pp...
: Component number
ss...
: Serial number
rr...
: Version
J D2
SSuu
0n
5
D200
uu
0
n
0
Power Supply Unit DE#
uu
/PSU#
n
Warning
<
pppppppppppp ssssssssss rrrr
>
PSU error is detected.
SS
: Component subtype
uu
: DE-ID ("00" for a controller enclosure)
n
: PSU number (0 – 1)
pp...
: Component number
ss...
: Serial number
rr...
: Version
J DA
SSuu
00
6
DA00
uu
00
1
DE Exhaust temperature DE#uu Warning
These messages are
notified when "Tem-
perature Warning" is
enabled for Warning
Level in the event
notification setting.
They are not notified
during maintenance
operations.
DE exhaust temperature error (Warning) is
detected.
SS
: Component subtype
uu
: DE-ID ("00" for a controller enclosure)
J DB
SSuu
00
6
DB00
uu
00
1
DE Intake temperature DE#
uu
Warning
DE intake temperature error (Warning) is detected.
SS
: Component subtype
uu
: DE-ID ("00" for a controller enclosure)
Event type
code
SNMP Trap
Upper: Message
Remarks
Trap
No.
TrapItemID
(*1)
Lower: Description