Set Disk Patrol
The disk patrol parameters are set.
$a
: Target disk type (None, Data, Spare,
Unused)
$b
: Write Check (Enable, Disable)
$c
: Check Code Check (Enable, Disable)
$d
: Disk Port Check (Enable, Disable)
$e
: Interval between each test increment [sec]
(1, 2, 3, 4, 5, 6, 7, 8, 9, 10)
$f
: Operation Size [MB] (0.5, 1.0, 2.0, 4.0, 8.0,
16.0)
$g
: Verify Check for Unused Area of Data Disk
(Enable, Disable)
[Disk_Type=
$a
Write_Check=
$b
Check_Code_Check=
$c
Disk_Port_Check=
$d
Interval=
$e
Operation_Size=
$f
Free_Area_Check=
$g
]
020C000A
Release Reservation
The reservation status of the volume is released.
$a
: Volume number
[Volume_No=
$a
]
020C000B
Set Disk Performance Monitor
The disk performance monitoring parameters are
changed.
$a
: Monitoring function (Enable, Disable)
$b
: Disk isolation (Enable, Disable)
$c
: Error monitoring factor [%] (0.1 – 10.0)
$d
: Threshold of allowable error (7.2 – 720.0)
$e
: Monitoring time [hour]
$f
: Event notification (Enable, Disable)
[Monitoring=
$a
Disk_Isolation=
$b
Factor=
$c
Threshold=
$d
Interval=
$e
Event_Notification=
$f
]
020C000E
Set Debug Mode
The debug mode is set.
$a
: Trace level (example: 00-FF)
$b
: Collection mode of the panic dump (Nose
and Tail, Fortnight, Disable)
[Trace_Level=
$a
Panic=
$b
]
020C000F
Start Performance
Performance information collection is started.
$a
: Collection interval [sec] (30, 60, 90, 120,
150, 180, 210, 240, 270, 300)
[Interval=
$a
]
020C0010
Stop Performance
Performance information collection is stopped.
Detail information is not displayed.
020C0011
Set Bind In Cache
The Bind-in-Cache memory size is changed.
$a
: New capacity (example: 256MB)
[Size=
$a
]
020C0012
Delete Event
All of the event logs are deleted.
Detail information is not displayed.
020C0013
Initialize System Disk
The BUD is initialized.
Detail information is not displayed.
020C0014
Change Master
The master CM is changed.
Detail information is not displayed.
020C0015
Write Back Pinned Data
The pinned data is written back to the volume.
$a
: Volume number
[No=
$a
]
020C0016
Clear Pinned Data
The pinned data in the cache memory is deleted.
$a
: Volume number
[No=
$a
]
020C0017
Forced Write Back
Write back is forcibly performed.
Detail information is not displayed.
020C0018
Forced Restore
Restoration is forcibly performed.
Detail information is not displayed.
Event code
Upper: Message
Description
Lower: Detailed information