Appendix B Audit Log List
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED
P3AM-4842-12ENZ0
177
020C0019
Recover Backup Restore Fail
The storage system is recovered from Backup Fail
status or Restore Fail status.
Detail information is not displayed.
020C001A
Recover Machine Down Recovery
The Machine Down Recovery Fail status is reset.
Detail information is not displayed.
020C001B
Reset All Controller Module
All of the controllers are rebooted.
Detail information is not displayed.
020C001C
Recover RAID Group
The RAID group is forcible recovered.
$a
: RAID group number
$b
: Recovery mode (Force, Disk)
[No=
$a
Mode=
$b
]
020C001D
Diagnose Disk
The disk diagnosis is started.
$a
: Disk (DE-ID + Slot number (example:
0000, 0001, 0002))
$b
: Count (1 - 65535)
$c
: Mode (Read Only, Write/Read/Compare)
[Disk=
$a
Count=
$b
Mode=
$c
]
020C001E
Diagnose RAID Group
The RAID group diagnosis is started.
$a
: RAID group number
$b
: Recovery mode (Enable, Disable)
[No=
$a
Auto_Recovery=
$b
]
020C001F
Stop Diagnosis
The diagnosis process is stopped.
$a
: Type (Disk, RAID Group)
$b
: RAID group number
[Type=
$a
RAID_No=
$b
]
020C0020
Clear Diagnosis
The diagnosis is complete.
$a
: Type (Disk, RAID Group)
$b
: RAID group number
[Type=
$a
RAID_No=
$b
]
020C0021
Set LED
The LED of the target component is turned on,
blinked, or turned off.
$a
: Target component (CE, Disk)
$b
: Drive (DE-ID + Slot number (example:
0000, 0001, 0002))
$c
: LED (ON, OFF)
[Target=
$a
Disk=
$b
LED=
$c
]
020C0022
Set Event Parameter
The LED display (turning on or blinking) settings
when an event occurs are set.
$a
: Blink Fault LED at warning (Enable,
Disable)
$b
: Turn on Fault LED when redundant copy is
completed (Enable, Disable)
[Warning_LED=
$a
Comp_Redundant_Copy_LED=
$b
]
020C0023
Shutdown
The storage system is off or rebooted.
$a
: Mode (Shutdown, Restart)
[Mode=
$a
]
020C0024
Set Differential Backup
The differential backup function is enabled or
disabled.
$a
: Differential Backup (Enable, Disable)
[Differential_Backup=
$a
]
020C0025
Set ODX Mode
The ODX function is enabled or disabled.
$a
: Mode (Enable, Disable)
[Mode=
$a
]
020C0026
Set CLI Idle Timeout
The idle timeout limit when using ETERNUS CLI is
set or displayed.
$a
: Timeout limit [minute] (5 – 60)
[Timeout=
$a
]
020D0001
Update Customer Information
The customer information is registered or
updated.
$a
: Deletion of the customer information in
the storage system (Yes, No)
[Delete_Customer_Identity_Info=
$a
]
Event code
Upper: Message
Description
Lower: Detailed information