Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED
P3AM-4842-12ENZ0
151
04
F8
00
The pinned data occurs.
This sense code is notified when "Pinned
data" is enabled for Error Severity Level
in the event notification setting.
This is not notified during maintenance
operations.
06
11
90
Writing of Bad Data (data lost identifier) occurs.
This sense code is notified when "Bad
data" is enabled for Error Severity Level
in the event notification setting.
This is not notified during maintenance
operations.
06
C1
01
CM is rebooted.
These messages are notified when
"Remote Path Error" is enabled for
Warning Level in the event notification
setting.
They are not notified during
maintenance operations.
06
C1
10
CA is rebooted.
06
C1
90
IOM is rebooted.
06
E2
92
Disconnection of a REC path between cabinets is detected.
This sense code is notified when
"Remote Path Error" is enabled for Error
Severity Level in the event notification
setting.
This is not notified during maintenance
operations.
06
F2
80
Rebuild has started.
This sense code is notified when
"Rebuild/Copyback w/o redundant" is
enabled for Error Severity Level in the
event notification setting.
This is not notified during maintenance
operations.
06
F2
80
Redundant copy is being performed.
This sense code is notified when
"Redundant" is enabled for Error Severity
Level in the event notification setting.
This is not notified during maintenance
operations.
06
F2
81
Rebuild to the drive has started.
These sense codes are notified when
"Rebuild/Copyback w/ redundant" is
enabled for Error Severity Level in the
event notification setting.
They are not notified during
maintenance operations.
06
F2
82
Rebuild to the hot spare is complete.
06
F2
82
Redundant copy is complete.
This sense code is notified when
"Complete Redundant Copy" is enabled
for Error Severity Level in the event
notification setting.
This is not notified during maintenance
operations.
06
F2
83
Rebuild to the drive is complete.
These sense codes are notified when
"Rebuild/Copyback w/ redundant" is
enabled for Error Severity Level in the
event notification setting.
They are not notified during
maintenance operations.
06
F2
84
Copyback is being performed.
06
F2
85
Copyback is complete.
06
F2
88
Rebuild to the hot spare or the replaced drive is complete,
but Bad Data (data lost identifier) exists.
These sense codes are notified when
"Complete rebuild" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during
maintenance operations.
Sense code
Description
Remarks
SK