Trouble shooting 4
INDOOR UNIT Error Method:
External communication error
02-07
Detective Actuators:
Detective details:
Forecast of Cause :
OK
OK
External communication error
Check any loose or removed connection of between the controller PCB to the external I/OPCB
>>If there is an abnormal condition, correct it by refer to installation manual or
the technical manual.
Check the connection condtion on the external I/O PCB and the controller PCB
(If there is loose connector, open cable or mis-wiring)
the same a signal has not been received for 15sec
After receiving a signal from the external I/O PCB,
1. Connection failure
2.External I/O PCB failure
3.Controller PCB failure
Check Point 1 : Check the connection
Indicate or Display:
Indoor Unit :
Operation lamp: 1 times Flash,
Timer lamp : 8 times Flash
ERROR CODE : [E : 18]
Check Point 2: Replace external I/O PCB
If Check Point 1 do not improve the symptom, change External I/O PCB.
OK
OK
Check Point 3: Replace Controller PCB
If Check Point 2 do not improve the symptom, change Controller PCB.
n: n times blinking
: Light ON
: Light OFF
Outdoor unit :
POWER
MODE
ERROR
2
5
(L1)
(L2)
(L6)
(L5)
(L4)
(L3)
15
PUMP
DOWN
LOW
NOISE
PEAK
CUT
Summary of Contents for AOU30RLXEH
Page 4: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Page 36: ...R410A WALL MOUNTED type INVERTER 2 TROUBLE SHOOTING ...
Page 89: ...R410A WALL MOUNTED type INVERTER 3 APPENDING DATA ...
Page 96: ...3 1 3 Procedures to change the Function Setting 03 07 ...
Page 120: ...3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan Jun 2016 Printed in Japan ...