1-00. ERROR HISTORY MODE
•
In this mode, the history of abnormality that occurred in the past can be confirmed.
( Table : 35 Procedure for history mode )
Procedure
Operation
Power
Mode
1
2
3
4
During status display, press the MODE SWITCH 2 times.
(Status display : Outdoor unit is stopping and no error)
When the EXIT SWITCH is pressed, this mode
ends and returns to the
status display
.
Selecting display items can be done by pressingthe
SELECT SWITCH. (Return to Procedure 3)
Press the ENTER SWITCH, Error code is displayed by
lighting LED. (Refer to TROUBLESHOOTING)
When the POWER / MODE LED blinking 2 times,
press the ENTER SWITCH.
: Light ON
: Light OFF
: Blinking
2 : 2
Times Blinking
n
:
n
Times Blinking
1-33-3 Error history mode
Error
L1
L2
L6
L5
L4
L3
2
2
2
2
2
5
Press the SELECT SWITCH and adjust to DISPLAY ITEM
(from L1 to L3) that you want to confirm.
(Refer to Table : 36)
n
n
DATA
LED
Power / Mode
LED
Display Item
ERROR
L1
L2
L3
( Table 36 : Display pattern
)
: Light ON
: Light OFF
n :
n Time Blinking
: Blinking
Newest error code
Error code before 1 time
Error Code
2
Error code before 2 times
01-31
Summary of Contents for AOU30RLXEH
Page 4: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Page 36: ...R410A WALL MOUNTED type INVERTER 2 TROUBLE SHOOTING ...
Page 89: ...R410A WALL MOUNTED type INVERTER 3 APPENDING DATA ...
Page 96: ...3 1 3 Procedures to change the Function Setting 03 07 ...
Page 120: ...3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan Jun 2016 Printed in Japan ...