1-16. COMPRESSOR PREHEATING
1-18.
MINIMUM HEAT OPERATION
1-17.
POWERFUL OPERATION
The MINIMUM HEAT operation functions by pressing MIN. HEAT button on the remote controller.
The MINIMUM HEAT operation can be set by the wireless remote controller.
* The timer and MINIMUM HEAT (Wireless R.C. only) functions of the remote controller specified
as the secondary cannot be used.
Mode
Heating
Setting temperature
50°F (10°C)
Fan mode
AUTO
( Table 17 : Minimum heat operation )
1-19.
ECONOMY OPERATION
The ECONOMY operation functions by pressing ECONOMY button on the remote controller.
The ECONOMY operation is almost the same operation as below settings.
Mode
Cooling/ Dry
Heating
Target temperature
Setting temp.+2°F (+1°C)
Setting temp.-2°F (-1°C)
( Table 18 : Economy operation )
The POWERFUL OPERATION functions by pressing POWERFUL button on the remote controller.
The indoor unit & outdoor unit will operate at maximum power as shown in Table 16.
Release Condition is as follows.
[Cooling / Dry]
- Room tenperature < Setting temperature -1°F(- 0.5°C) or Operation time has passed 20 minutes.
COMPRESSOR FREQUENCY Maximum
FAN CONT. MODE
Powerful
SETTING LOUVER
Cooling/ Dry : 3, Heating : 5
( Table 16 : Powerful operation )
Powerful operation
=
=
[Heating]
- Room tenperature > Setting tempe1°F(+ 0.5°C) or Operation time has passed 20 minutes.
When the outdoor temperature is lower than 68°F (20°C) and the all operation mode has been
stopped for 30 minutes, power is applied to the compressor and the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started and when the outdoor temperature rises to 78.8°F (26°C) or greater,
preheating is ended.
01-16
Summary of Contents for AOU30RLXEH
Page 4: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Page 36: ...R410A WALL MOUNTED type INVERTER 2 TROUBLE SHOOTING ...
Page 89: ...R410A WALL MOUNTED type INVERTER 3 APPENDING DATA ...
Page 96: ...3 1 3 Procedures to change the Function Setting 03 07 ...
Page 120: ...3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan Jun 2016 Printed in Japan ...