- 18 -
W
A
LL
MOU
N
TED
ASTG30, 34
KMTA
9. Safety devices
*PCB: Printed Circuit Board
Type of
protection
Protection form
Model
ASTG30KMTA
ASTG34KMTA
Circuit protection Current fuse (PCB*)
250 V, 3.15 A
Fan motor
protection
Thermistor protection
Activate
More than 85 °C
Fan motor speed down
Reset
85 °C or less
Fan motor speed recover
Power IC thermal
shutdown protection
Activate
150±15 °C
Fan motor stop
Reset
Less than 135 °C
Fan motor restart