6. Additional charge calculation
6-1. Model: AOTG30KMTA
Refrigerant charge
6-2. Model: AOTG34KMTA
Refrigerant charge
Refrigerant type
R32
Refrigerant amount
g
1,650
Total pipe length
m
20 or less
30
40
50 (Max.)
40 g/m
Additional charge
g
0
400
800
1,200
Refrigerant type
R32
Refrigerant amount
g
2,000
Total pipe length
m
30 or less
40
50 (Max.)
45 g/m
Additional charge
g
0
450
900