- 43 -
O
U
T
D
OOR UNIT
AOTG30, 34KMT
A
1-2. Model: AOTG34KMTA
Type
Inverter heat pump
Model name
AOTG34KMTA
Power supply
240 V ~ 50 Hz
Available voltage range
198—264 V
Starting current
A
12.9
Fan
Airflow rate
Cooling
l/s (m
3
/h)
1,139 (4,100)
Heating
1,139 (4,100)
Type × Q'ty
Propeller fan × 1
Motor output
W
111
Sound pressure level *1
Cooling
dB(A)
50
Heating
54
Sound power level
dB(A)
67
Heat exchanger type
Dimensions (H × W × D)
mm
Main: 882 × 957 × 18.19 & 882 × 927 × 18.19
Sub: 882 × 580 × 18.19
Fin pitch
1.45
Rows × Stages
Main: 2 × 42, Sub: 1 × 42
Pipe type
Copper
Fin
Type (Material)
Corrugate (Aluminum)
Surface
treatment
Corrosion resistance (Blue fin)
Compressor
Type × Q'ty
Hermetic motor compressor × 1
Motor output
W
2,200
Refrigerant
Type
R32
Charge
g
2,000
Refrigerant oil
Type
RmM68AF
Amount
cm
3
800
Enclosure
Material
Steel sheet
Color
Beige
Approximate color of Munsell 10YR7.5/1.0
Dimensions
(H × W × D)
Net
mm
914 × 970 × 370
Gross
1,048 × 1,064 × 479
Weight
Net
kg
75
Gross
82
Connection pipe
Size
Liquid
mm (in)
Ø 9.52 (Ø 3/8)
Gas
Ø 15.88 (Ø 5/8)
Method
Flare
Pre-charge length
m
30
Max. length
50
Max. height difference
30
Operation range
Cooling
°C
-10 to 46
Heating
-15 to 24
Drain hose
Material
LDPE
Size
mm
Ø 13.0 (I. D.), Ø 16.0 to Ø 16.7 (O. D.)
International protection rating
IPX4
NOTES:
Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 7.5 m, Height difference: 0 m.
Protective function might work when using it outside the operation range.
*1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Summary of Contents for AOTG30KMTA
Page 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASTG30KMTA ASTG34KMTA ...
Page 15: ... 11 WALL MOUNTED ASTG30 34KMTA 5 Wiring diagram ...
Page 21: ... 17 WALL MOUNTED ASTG30 34KMTA 8 2 Sound level check point 0 8 m 1 m Microphone Microphone ...
Page 44: ... 40 WALL MOUNTED ASTG30 34KMTA ...
Page 45: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOTG30KMTA AOTG34KMTA ...
Page 56: ... 52 OUTDOOR UNIT AOTG30 34KMTA 3 Refrigerant circuit 3 1 Model AOTG30KMTA ...
Page 57: ... 53 OUTDOOR UNIT AOTG30 34KMTA 3 2 Model AOTG34KMTA ...
Page 58: ... 54 OUTDOOR UNIT AOTG30 34KMTA 4 Wiring diagrams 4 1 Model AOTG30KMTA ...
Page 59: ... 55 OUTDOOR UNIT AOTG30 34KMTA 4 2 Model AOTG34KMTA ...