background image

Inverter One-Two / One-Three/
One - Four Split-Type
ROOM AIR CONDITIONER

INSTALLATION  MANUAL

MODEL #: 

TAS-18MVHN/O
TAS-27MVHN/O
TAS-36MVHN/O

Please read this manual carefully and thoroughly before
operating the unit.
If you still have any difficulties or problems, consult your
dealer for help or  Turbo Air Conditioning Corp.

Please keep this manual handy. 

W1

Summary of Contents for TAS-18MVHN/O

Page 1: ...LATION MANUAL MODEL TAS 18MVHN O TAS 27MVHN O TAS 36MVHN O Please read this manual carefully and thoroughly before operating the unit If you still have any difficulties or problems consult your dealer...

Page 2: ...ment The actual shape should prevail Contact an authorised service technician for repair or maintenance of this unit Contact an authorised installer for installation of this unit The air conditioner i...

Page 3: ...ring standard regulation and this installation instructions An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it wil...

Page 4: ...radiation from the condenser is not restricted Ensure that the clearance around the back of the unit is more than 30cm 12inch and left side is more than 30cm 12inch The front of the unit should have m...

Page 5: ...r details Drain Joint Connecting pipe Assembly Liquid side Plastic Expansion Sheath Number Q ty one unit Gas side 9 Remote controller holder 1 12000Btu h model 12000Btu h model See page 8 for details...

Page 6: ...f the A B and C directions should be free from obstructions CAUTION INSTALLATION INSTRUCTIONS 5 CAUTIONS One Two One Three One Four More than 12cm 4 72inch Air filter Remote controller More than 12cm...

Page 7: ...hole positions according to the diagramdetailed in Fig 5 Drill one 1 hole 65mm 2 56inch slanting slightly to outdoor side 2 Always use wall hole conduit when drilling metal grid metal plate or the lik...

Page 8: ...ig 10 4 Piping and wrapping Bundle the tubing connecting cable and drain hose with tape securely evenly as shown in Fig 11 Because the condensed water from rear of the indoor unit is gathered in pondi...

Page 9: ...easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall Get it out after finish piping 4 Push the lower part of the indoor unit up on the wall then m...

Page 10: ...sible hooks fittings Face the concave side of the installation hooks toward the expansible hooks Determine the length of the installation hooks from the height of ceiling then cut off the unnecessary...

Page 11: ...n bulgy objects Never crash or strike it a Slide two grid switches toward the middle at the same time and then pull them up Refer to Fig 21 o b Draw the grid up to an angle of about 30 and remove it R...

Page 12: ...e that hooks of four corners are fixed well f Keep fastening the screws under the panel hooks until the thickness of the sponge between the body and the panel s outlet has been reduced to about 4 6mm...

Page 13: ...ave H There is combustible gas or materials I There is much evaporating acid or alkaline gas J Other special areas Enough room for installation and maintenance The ceiling is horizontal and it can aff...

Page 14: ...ction place before overhanging the unit Install the hanging bolt in following different situation Timber over the beam Blade shape insertion Slide insertion Install with insertion or embedding screw W...

Page 15: ...air inlet grille and air inlet direction in parallel as shown in Fig 34a Fig 34b is incorrect which may cause loud noise CAUTION Drainpipe installation Piping insulation material Drainage Heat insulat...

Page 16: ...ine specification Function Duct installation board 8 Connecting duct Fixation bolt fixing installation board 8 ST3 9 10 F H Fixing duct installation board Instructions for duct installation accessorie...

Page 17: ...Its Frame 1 2 3 Mounting screw B ST2 9x10 C H Remote controller holder Remote controller Never throw or beat the controller Before installation operate the remote controller to determine its location...

Page 18: ...e connection places before hanging up the machine The installation of hanging screw bolts 4 2 Indoor unit installation 4 3 Wall Mounting Installation 1 Installing 10 0 39 hanging screw bolts 4 bolts 2...

Page 19: ...h models do not remove the grille Washer Tapping screw Hook 0 024inch Fig 42 7 Fig 42 8 Fig 42 9 Fig 42 10 Fig 42 12 Fig 42 11 Fig 42 13 4 4 Ceiling Installation Hanging arm Side board Grille Screw n...

Page 20: ...atteries This manual is subject to changes due to technological improvement without further notices Remote controller Remote controller holder Mounting screw B ST2 9x10 C H SET TEMPERATURE O C AUTO CO...

Page 21: ...5 4 Install the connecting pipe Console 5 4 1 The procedure of connecting pipes Check whether the height drop between the indoor unit and outdoor unit the length of refrigerant pipe and the number of...

Page 22: ...flare pipe joints and refrigerant pipe on the liquid side and the gas side Ensure that there is no gap between them Incomplete insulation may cause water condensation How to take indoor unit apart to...

Page 23: ...power supply to the air conditioner should have ground wiring which is linked to the ground wiring of the indoor and outdoor unit The wiring work should be done by qualified persons according to circ...

Page 24: ...dmission of wind If need suspending installation the installation bracket should accord with technique requirement in the installation bracket diagram The installation wall should be solid brick concr...

Page 25: ...the pipes and the cable 1 Use the piping kit accessory or pipes purchased locally 2 Measure the distance between the indoor and the outdoor unit 3 Cut the pipes a little longer than the measured dista...

Page 26: ...52 Indoor unit tubing Flare nut Pipings Fig 51 Electric safety regulations for the initial Installation 1 If there is serious safety problem about the power supply the technicians should refuse to ins...

Page 27: ...39inch CAUTIONS Do not touch the capacitor even if you have disconnected the power for there is still high voltage power on it or electric shock hazard may occur For your safety you should start repa...

Page 28: ...the Electrical Control cover and screw rip off the white paper above the Slide Switch and move it to the MULTI position see Fig 56 5 Reinstall the front panel and frame 6 Now the indoor unit can be u...

Page 29: ...d wiring and have an air gap contact separation of at least 3mm 0 12inch in each active phase conductors CAUTION CAUTION CAUTION CAUTION Air and moisture in the refrigerant system have undesirable eff...

Page 30: ...the handle Lo of the manifold valve 4 Operate the vacuum pump to evacuate After starting evacuation slightly loose theflare nut of the Lo valve on the gas pipe side and check that the air is entering...

Page 31: ...nd D are ends of indoor unit connection CAUTION Electrical safety check Gas leak check 1 Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor uni...

Page 32: ...well 3 When the amient temperature is too low lower than 17 62 6 the unit cannot be controlled by the remote controller to run at cooling mode manual operation can be taken Manual operation is used on...

Page 33: ...TA CS045I BPV1 0301 2020001A6007...

Reviews: