Selecting installation place

Read completely, then follow step by step.

Indoor unit

Do not expose the indoor unit to heat or steam.
Select a place where there are no obstacles 
in front or around the unit.
Make sure that condensation drainage can 
be conveniently routed away.
Do not install near a doorway.
Ensure that the space on the left and right 
of the unit is more than 12cm(4.72inch).  
Use a stud finder to locate studs to prevent unnecessary damage to the wall. 
The indoor unit should be installed on the wall at a height of 2m(79inch) or more from the floor.
The indoor unit should be installed allowing a minimum clearance of 6inch from the ceiling.
Any variations in pipe length will/may require adjustment to refrigerant charge.
There should not be any direct sunlight. Otherwise, the sun will fade the plastic  cabinet and 
affect its appearance. If unavoidable, sunlight prevention should be taken into consideration.

Outdoor unit

If an awning is built over the outdoor unit to 
prevent direct sunlight or rain exposure, 
make sure that heat radiation from the 
condenser is not restricted.
Ensure that the clearance around the back 
of the unit is more than 30cm(12inch)  and left side is 
more than 30cm(12inch) . The front of the unit should 
have more than 2m(79inch) of clearance and the 
connection side (right side) should have more
than 60cm(24inch) of clearance.
Do not place animals and plants in the path of the air inlet or outlet.
Take the air conditioner weight into account and select a place where noise and vibration 
will not be an issue.
Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.

If the outdoor unit is installed on a roof structure, be sure to level the unit. 
Ensure the roof structure and anchoring method are adequate for the unit location.
Consult local codes regarding rooftop mounting.
If the outdoor unit is installed on roof structures or external walls, this may result in 
excessive  noise and vibration, and may also be classed as a non serviceable installation.

Rooftop installation:

 INSTALLATION INSTRUCTIONS

More than 30cm(12inch)

More than60cm(12inch)

More than 30cm(12inch)

More than 200cm(79inch)

Fig.2

More than  2m(79inch)

More than 15cm(6inch)

More than12cm( 4.72inch)

More than 12cm(4.72inch)

Fig.1

1. Wall-mounted type

Summary of Contents for TAS-18MVHN/O

Page 1: ...LATION MANUAL MODEL TAS 18MVHN O TAS 27MVHN O TAS 36MVHN O Please read this manual carefully and thoroughly before operating the unit If you still have any difficulties or problems consult your dealer...

Page 2: ...ment The actual shape should prevail Contact an authorised service technician for repair or maintenance of this unit Contact an authorised installer for installation of this unit The air conditioner i...

Page 3: ...ring standard regulation and this installation instructions An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it wil...

Page 4: ...radiation from the condenser is not restricted Ensure that the clearance around the back of the unit is more than 30cm 12inch and left side is more than 30cm 12inch The front of the unit should have m...

Page 5: ...r details Drain Joint Connecting pipe Assembly Liquid side Plastic Expansion Sheath Number Q ty one unit Gas side 9 Remote controller holder 1 12000Btu h model 12000Btu h model See page 8 for details...

Page 6: ...f the A B and C directions should be free from obstructions CAUTION INSTALLATION INSTRUCTIONS 5 CAUTIONS One Two One Three One Four More than 12cm 4 72inch Air filter Remote controller More than 12cm...

Page 7: ...hole positions according to the diagramdetailed in Fig 5 Drill one 1 hole 65mm 2 56inch slanting slightly to outdoor side 2 Always use wall hole conduit when drilling metal grid metal plate or the lik...

Page 8: ...ig 10 4 Piping and wrapping Bundle the tubing connecting cable and drain hose with tape securely evenly as shown in Fig 11 Because the condensed water from rear of the indoor unit is gathered in pondi...

Page 9: ...easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall Get it out after finish piping 4 Push the lower part of the indoor unit up on the wall then m...

Page 10: ...sible hooks fittings Face the concave side of the installation hooks toward the expansible hooks Determine the length of the installation hooks from the height of ceiling then cut off the unnecessary...

Page 11: ...n bulgy objects Never crash or strike it a Slide two grid switches toward the middle at the same time and then pull them up Refer to Fig 21 o b Draw the grid up to an angle of about 30 and remove it R...

Page 12: ...e that hooks of four corners are fixed well f Keep fastening the screws under the panel hooks until the thickness of the sponge between the body and the panel s outlet has been reduced to about 4 6mm...

Page 13: ...ave H There is combustible gas or materials I There is much evaporating acid or alkaline gas J Other special areas Enough room for installation and maintenance The ceiling is horizontal and it can aff...

Page 14: ...ction place before overhanging the unit Install the hanging bolt in following different situation Timber over the beam Blade shape insertion Slide insertion Install with insertion or embedding screw W...

Page 15: ...air inlet grille and air inlet direction in parallel as shown in Fig 34a Fig 34b is incorrect which may cause loud noise CAUTION Drainpipe installation Piping insulation material Drainage Heat insulat...

Page 16: ...ine specification Function Duct installation board 8 Connecting duct Fixation bolt fixing installation board 8 ST3 9 10 F H Fixing duct installation board Instructions for duct installation accessorie...

Page 17: ...Its Frame 1 2 3 Mounting screw B ST2 9x10 C H Remote controller holder Remote controller Never throw or beat the controller Before installation operate the remote controller to determine its location...

Page 18: ...e connection places before hanging up the machine The installation of hanging screw bolts 4 2 Indoor unit installation 4 3 Wall Mounting Installation 1 Installing 10 0 39 hanging screw bolts 4 bolts 2...

Page 19: ...h models do not remove the grille Washer Tapping screw Hook 0 024inch Fig 42 7 Fig 42 8 Fig 42 9 Fig 42 10 Fig 42 12 Fig 42 11 Fig 42 13 4 4 Ceiling Installation Hanging arm Side board Grille Screw n...

Page 20: ...atteries This manual is subject to changes due to technological improvement without further notices Remote controller Remote controller holder Mounting screw B ST2 9x10 C H SET TEMPERATURE O C AUTO CO...

Page 21: ...5 4 Install the connecting pipe Console 5 4 1 The procedure of connecting pipes Check whether the height drop between the indoor unit and outdoor unit the length of refrigerant pipe and the number of...

Page 22: ...flare pipe joints and refrigerant pipe on the liquid side and the gas side Ensure that there is no gap between them Incomplete insulation may cause water condensation How to take indoor unit apart to...

Page 23: ...power supply to the air conditioner should have ground wiring which is linked to the ground wiring of the indoor and outdoor unit The wiring work should be done by qualified persons according to circ...

Page 24: ...dmission of wind If need suspending installation the installation bracket should accord with technique requirement in the installation bracket diagram The installation wall should be solid brick concr...

Page 25: ...the pipes and the cable 1 Use the piping kit accessory or pipes purchased locally 2 Measure the distance between the indoor and the outdoor unit 3 Cut the pipes a little longer than the measured dista...

Page 26: ...52 Indoor unit tubing Flare nut Pipings Fig 51 Electric safety regulations for the initial Installation 1 If there is serious safety problem about the power supply the technicians should refuse to ins...

Page 27: ...39inch CAUTIONS Do not touch the capacitor even if you have disconnected the power for there is still high voltage power on it or electric shock hazard may occur For your safety you should start repa...

Page 28: ...the Electrical Control cover and screw rip off the white paper above the Slide Switch and move it to the MULTI position see Fig 56 5 Reinstall the front panel and frame 6 Now the indoor unit can be u...

Page 29: ...d wiring and have an air gap contact separation of at least 3mm 0 12inch in each active phase conductors CAUTION CAUTION CAUTION CAUTION Air and moisture in the refrigerant system have undesirable eff...

Page 30: ...the handle Lo of the manifold valve 4 Operate the vacuum pump to evacuate After starting evacuation slightly loose theflare nut of the Lo valve on the gas pipe side and check that the air is entering...

Page 31: ...nd D are ends of indoor unit connection CAUTION Electrical safety check Gas leak check 1 Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor uni...

Page 32: ...well 3 When the amient temperature is too low lower than 17 62 6 the unit cannot be controlled by the remote controller to run at cooling mode manual operation can be taken Manual operation is used on...

Page 33: ...TA CS045I BPV1 0301 2020001A6007...

Reviews: