5-1. COOLING OPERATION
5-1-1 COOLING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is 2 degC higher than a set temperature,
the compressor operation frequency will attain to maximum performance.
* If the room temperature is 2 degC lower than a set temperature, the compressor
will be stopped.
* When the room temperature is b2 degC to -2 degC of the setting temperature,
the compressor frequency is controlled within the range shown in Table1.
However, the maximum frequency is limited in the range shown in Figure 1 based on the
fan speed mode and the outdoor temperature.
minimum
frequency
maximum
frequency
20Hz
20Hz
20Hz
90Hz
90Hz
92Hz
AB*30LBAG
AB*36LBAG
AB*45LBAG
Outdoor air
temperature
A zone
31°C
B zone
C zone
D zone
Hi
Me
Lo
A zone
90Hz
70Hz
65Hz
55Hz
90Hz
92Hz
72Hz
60Hz
60Hz
75Hz
70Hz
65Hz
45Hz
75Hz
70Hz
65Hz
55Hz
72Hz
60Hz
45Hz
75Hz
70Hz
60Hz
60Hz
53Hz
53Hz
65Hz
70Hz
65Hz
70Hz
55Hz
72Hz
60Hz
65Hz
55Hz
55Hz
B zone
C zone
D zone
A zone
B zone
C zone
AB*30LBAG
D zone
A zone
B zone
C zone
AB*36LBAG
D zone
AB*45LBAG
19°C
11°C
( Table 1 : Compressor Frequency Range )
( Fig. 1 : Limit of Maximum Frequency based on Outdoor Temperature )
05-01
Fan speed mode
Summary of Contents for AB*30LBAG series
Page 5: ...1 SPECIFICATIONS R410A INVERTER Large Ceiling type ...
Page 8: ...2 DIMENSIONS R410A INVERTER Large Ceiling type ...
Page 11: ...3 REFRIGERANT SYSTEM DIAGRAM R410A INVERTER Large Ceiling type ...
Page 14: ...4 CIRCUIT DIAGRAM R410A INVERTER Large Ceiling type ...
Page 18: ...5 DESCRIPTION OF EACH CONTROL OPERATION R410A Large Ceiling type INVERTER ...
Page 37: ...6 REFRIGERANT CAUTION R410A R410A INVERTER Large Ceiling type ...
Page 46: ...7 TROUBLE SHOOTING R410A INVERTER Large Ceiling type ...
Page 77: ...8 APPENDING DATA R410A INVERTER Large Ceiling type ...
Page 88: ...9 INSTALLATION MANUAL R410A INVERTER Large Ceiling type ...
Page 93: ...10 REPLACEMENT PARTS R410A INVERTER Large Ceiling type ...
Page 126: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan May 2006 Printed in Japan ...