![Fuji Electric MICREX-SX series User Manual Download Page 36](http://html.mh-extra.com/html/fuji-electric/micrex-sx-series/micrex-sx-series_user-manual_2341770036.webp)
Section 3 Inverter Communication
3-4
3-4 Error Code
Function code group
Function code
(Hexadecimal)
Write/read No.
(Decimal)
F
00
00 to 99
E
01
00 to 99
C
02
00 to 99
P
03
00 to 99
H
04
00 to 99
A
05
00 to 99
o (lowercase)
06
00 to 99
S
07
00 to 99
M
08
00 to 99
L
09
00 to 99
J
0D
00 to 99
y (lowercase)
0E
00 to 99
W
0F
00 to 99
X
10
00 to 99
Z
11
00 to 99
3-5 Inverter Function Code and Write/Read No.
The table below shows the “function codes” and “write/read Nos.” of an inverter. Set them as follows:
Code
Name
Cause
00
Normal end
This indicates a normal response frame that the inverter issued.
1C
Password verification error
Password mismatch
1D
Password setting response
This is a response to a request for password setting.
1E
No password registered
Although no password is registered, a password is entered.
20
Undefined command received
A command cannot be processed because it is not defined.
21
Split parameter error
There is no continuity between SEQ_NO and end information.
22
Parameter error
Connection method setting error (The connection method is not "7A".)
Number of bytes is erroneous.
23
Interlock error
Transmission interlock code is erroneous.
2A
Invalid command received
Although processing is not in progress, a continue or cancel command is
received.
2B
Other loader processing in progress
When processing is in progress, a command other than continue or cancel
command is received.
Note: For detail specifications of the function code, refer to the manual of the inverter function.