![Fuji Electric FSC-2 Instruction Manual Download Page 87](http://html1.mh-extra.com/html/fuji-electric/fsc-2/fsc-2_instruction-manual_2341885087.webp)
78
INF-TN2FSC-E
(3) CUT OFF: output cut off at low flow rate (low flow cutoff function)
0.010m/s
Flow velocity
- 0.010m/s
Output
When flow rate is extremely low, its output can
be cut off. (range: 0 to 5.000 m/s)
If fluid in the pipe is moving due to convec-
tion, etc., even though the valve is closed, this
flowmeter outputs a measured value. There-
fore, values below an appropriate level should
be cut off.
[Operation]
(1) Press the or key on the OUTPUT CONTROL
screen and select “CUT OFF”. Then, press the
ENT
key, and the cursor moves to the set item. Output cut
off point is settable.
(2) Move the digit by pressing the or key and
enter a numeric value by pressing the or key.
After entry, press the
ENT
key.