142
CP-100 • User’s Guide
_K==oÉãçíÉ=`çåíêçä
Remote Commands
fsm^k=
•
Description
: Input Vertical Pan
•
Command Format
: IVPAN -i (input) -p (pan)
•
Parameters
:
-i (input): 1 - 9
-p (pan): In pixels
•
Query Format
: IVPAN -i (input) -?
•
Query Response
: IVPAN -i (input) -p (pan) --min (active min) -- max (active
max)
fsmlp
•
Description
: Input Vertical Position Adjust. This command is only adjustable for
analog input types. Other input types will provide query information only.
•
Command Format
: IVPOS -i (input) -p (position)
•
Parameters
:
-i (input): 1 - 8 for adjustments (7 & 8 only if input is analog); 1 - 9 for
query
-p (position): In lines
•
Query Format
: IVPOS -i (input) -?
•
Query Response
: IVPOS -i (input) -p (position) --min (pos min) -- max (pos max)
fsqlq^i
•
Description
: Input Vertical Total Adjust. This command is a query only.
•
Parameters
: -i (input): 1 - 9
•
Query Format
: IVTOTAL -i (input) -?
•
Query Response
: IVTOTAL -i (input) -t (total)
m`ljm=
•
Description
: Pulldown Compensation mode adjust.
•
Command Format
: PCOMP -i (input) -m (mode)
•
Parameters
: -i (input):1 - 9
-m(mode): 0 - off, 1 - on (Default: off)
•
Query Format
: PCOMP -i (input) -?
•
Query Response
: PCOMP -i (input) -m (mode) --min 0 -- max 1
q^hb
•
Description
: Take the input currently on preview onto program.
•
Command Format
: TAKE
•
Command Params
: None