2.1 Initial Startup
Wash the unit and accessories thoroughly with hot, soapy water to remove any film residue, dust or debris. Rinse and
wipe dry. Close the drain valve completely. Ensure the operating thermostat and high-limit thermostat sensing bulbs
inside the frypot are securely seated in the holding clamp.
2.1.1 Operating the Gas Valve
Rotate the knob counter-clockwise to the
ON
or
PILOT
positions. Depress and rotate the knob clockwise to turn the
valve
OFF
.
O
FF
ON
PIL
OT
O
FF
ON
PIL
OT
PILOT Position
ON Position
2.1.2 Pilot Lighting Procedures
NOTE:
This fryer was tested, adjusted and calibrated to sea level conditions before leaving the factory. Adjustments
may be necessary to meet local conditions and are to be performed only by qualified service personnel. Adjustments are
the responsibilities of the customer or dealer and are not covered by Dean warranty.
The pilot is located high in the cabinet center, at the base of the frypot. Use a long match or taper to light the pilot.
Perform the following steps in sequence before lighting the pilot:
1.
Turn off the manual shut-off valve on the incoming gas supply line.
2.
Turn the operating thermostat to the
OFF
position.
3.
Depress and turn the gas valve knob to the
OFF
position.
4.
Wait at least 5 minutes for any accumulated gas to disperse.
5.
Fill the frypot with oil, shortening or water to the bottom
OIL LEVEL
line scribed on the frypot back. Ensure
heating tubes are covered in liquid prior to engaging burners.
NOTE:
If solid shortening is used, pack the shortening into the frypot, ensuring the shortening is packed beneath,
between and above the tubes prior to operating fryer.
6.
Open the manual shut-off valve on the incoming gas supply line and rotate the gas valve knob to the
PILOT
position.
7.
Push and hold the knob in and apply a lighted match or taper to the pilot burner head. Continue to hold the knob in
for about 60 seconds after the flame appears on the pilot. Release the knob. The pilot should remain lit.
DANGER
If the pilot fails to remain lit, turn the gas valve "OFF" and wait 5 minutes before attempting to re-light.
ENGL
ISH
Summary of Contents for Dean Super Runner Series
Page 3: ...Register Your Warranty Online at http fm hal frymaster com qsys lib cgi lib swr290 pgm ENGLISH...
Page 11: ...SUPER RUNNER SERIES GAS FRYERS CHAPTER 2 OPERATION 2 3 2 5 Wiring Diagram ENGLISH...
Page 12: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 15: ...Registre su garant a en l nea en http fm hal frymaster com qsys lib cgi lib swr290 pgm ESPA OL...
Page 23: ...FREIDORAS DE GAS SERIE SUPER RUNNER CAP TULO 2 OPERACI N 2 3 2 5 Diagrama de cableado ESPA OL...
Page 24: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 35: ...FRITEUSES GAZ SUPER RUNNER CHAPITRE 2 MODE D EMPLOI 2 3 2 5 Diagramme de c blage FRAN AIS...