72
Exiting the setup menu
Welding parame-
ters for MIG/MAG
welding in the
Setup menu level
2
Press and hold the "Mode" button
Press the "Process" button
Release the "Mode" and "Process" buttons
13
14
15
C-C
Cooling unit control
Unit: -
Setting range: Aut, On, Off
Factory setting: Aut
Aut: The cooling unit cuts out after a 2-minute welding off-time.
IMPORTANT!
If the coolant temperature and flow monitoring options have been
installed in the cooling unit, the cooling unit cuts out as soon as the return-flow
temperature drops below 50°C, but at the earliest after a 2-minute welding off-
time.
On: The cooling unit is permanently ON
Off: The cooling unit is permanently OFF
IMPORTANT!
If the FAC welding parameter is used, the C-C parameter is not
restored to the factory setting. If the MMA welding process is selected, the cool-
ing unit is always switched off, even if the switch is in the "On" position.
C-t
Cooling time - time from when flow monitoring is triggered until the "no | H2O"
service code is output. For example, if there are air bubbles in the cooling sys-
tem, the cooling unit will not cut out until the end of this pre-set time.
Unit: s
Setting range: 5 - 25
Factory setting: 10
IMPORTANT!
Every time the power source is switched on, the cooling unit car-
ries out a test run for 180 seconds.
SEt
Setting - country-specific setting (Standard/USA) ... Std / US
Unit: -
Setting range: Std, US (Standard/USA)
Factory setting:
Standard version: Std (measurements: cm/mm)
USA version: US (measurements: inches)
r
r (resistance) - welding circuit resistance (in mOhm)
see "Measuring welding circuit resistance r"
L
L (inductivity) - welding circuit inductivity (in microhenry)
see "Displaying welding circuit inductivity L"
Summary of Contents for TransSteel 3500 Rob
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 20: ...20...
Page 21: ...General information...
Page 22: ......
Page 27: ...Control elements and connections...
Page 28: ......
Page 35: ...Installation and commissioning...
Page 36: ......
Page 46: ...46...
Page 47: ...Welding...
Page 48: ......
Page 61: ...61 EN Number 3 Number 4 Number 5...
Page 62: ...62...
Page 63: ...Setup settings...
Page 64: ......
Page 76: ...76...
Page 77: ...Troubleshooting and maintenance...
Page 78: ......
Page 99: ...Appendix...
Page 100: ...100 Spare parts list TSt 3500 Rob TSt 5000 Rob...