Troubleshooting
General
The power sources are equipped with an intelligent safety system. This means that it has
been possible to dispense with melting-type fuses entirely. Melting-type fuses therefore no
longer need to be replaced. After a possible malfunction has been remedied, the power
source is ready for use again.
Safety
Power source -
troubleshooting
Make a note of the serial number and configuration of the device and contact our After-
Sales Service team with a detailed description of the error, if
-
errors occur that are not listed below
-
the troubleshooting measures listed are unsuccessful
Over-temperature LED lights up
Cause:
Over-temperature in control circuit
Remedy:
Leave power source to cool
Power source has no function
Mains switch is on, but indicators are not lit up
Cause:
There is a break in the mains lead; the mains plug is not plugged in
Remedy:
Check the mains lead, ensure that the mains plug is plugged in
Cause:
Mains socket or mains plug faulty
Remedy:
Replace faulty parts
Cause:
Mains fuse protection
Remedy:
Change the mains fuse protection
WARNING!
Work that is carried out incorrectly can cause serious injury and dam-
age. The following activities must only be carried out by trained and qualified per-
sonnel. Observe the safety rules in the power source operating instructions.
Summary of Contents for TransSteel 3500 Rob
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 20: ...20...
Page 21: ...General information...
Page 22: ......
Page 27: ...Control elements and connections...
Page 28: ......
Page 35: ...Installation and commissioning...
Page 36: ......
Page 46: ...46...
Page 47: ...Welding...
Page 48: ......
Page 61: ...61 EN Number 3 Number 4 Number 5...
Page 62: ...62...
Page 63: ...Setup settings...
Page 64: ......
Page 76: ...76...
Page 77: ...Troubleshooting and maintenance...
Page 78: ......
Page 99: ...Appendix...
Page 100: ...100 Spare parts list TSt 3500 Rob TSt 5000 Rob...
Page 102: ...102...
Page 103: ...103...