75
EN
Displaying welding circuit inductivity L
General
Laying of the hosepacks has a significant effect on welding circuit inductivity and therefore
affects the welding process. It is important to lay the hosepacks correctly in order to obtain
the best possible welding result.
Displaying weld-
ing circuit induc-
tivity L
The setup parameter "L" is used to display the most recently calculated welding circuit in-
ductivity. The welding circuit inductivity is calibrated at the same time as the welding circuit
resistance r is calculated. Detailed information can be found in the "Measuring welding cir-
cuit resistance r" section.
Access the setup menu level 2 (2nd)
Select parameter “L”
The most recently calculated welding circuit inductivity L is shown on the right-hand digital
display.
L
... Welding circuit inductivity (in microhenry)
Laying the hose-
packs correctly
1
2