59
EN-US
Service, maintenance and disposal
Before Every
Start-up
Check the fill level in the ‘Robacta Reamer’ parting agent container and top up if nec-
essary
Daily
Remove any deposited parting agent and contamination from the outside of the base
unit and cleaning unit.
Weekly
Empty the cleaning unit’s welding residue collecting container
Clean the inside of the cleaning unit’s cleaning aperture
Check the ‘Robacta Reamer’ parting agent container for contamination and clean if
necessary
Blow out the intake filter in the ‘Robacta Reamer’ parting agent container from the in-
side out with compressed air using the intake hose (see section
ter in the parting agent container
If present, check the condition of the brush seal above the cleaning aperture. If the
brush seal is worn out, replace it
Every Six Months
Open the base unit and cleaning unit and blow clean with dry and reduced com-
pressed air
Every 12 Months
Have a Fronius service technician perform a safety inspection on the cleaning device
Clean the intake
filter in the part-
ing agent contain-
er
1
NOTE!
Only clean the devices with cleaning products that are free of solvents.
1
1
2
3
4
5
NOTE!
Do not blow electronic parts clean from a short distance away.
1
1
NOTE!
Only use the ‘Robacta Reamer’ parting agent provided by the manufac-
turer. Its composition is specifically tailored for use with the Robacta TC. Correct
operation is not ensured when other products are used.
Summary of Contents for Cleaning Unit TC 2000
Page 2: ...2...
Page 4: ...4...
Page 15: ...General...
Page 16: ......
Page 24: ...24...
Page 25: ...Operating controls connections and mechanical components...
Page 26: ......
Page 34: ...34...
Page 35: ...Installation and Startup...
Page 36: ......
Page 43: ...43 EN US 4 Tightening torque 1 3 Nm 5 Tightening torque 0 5 Nm 6 4 1 5 1 2 3 4 6...
Page 52: ...52...
Page 53: ...Troubleshooting Maintenance and Disposal...
Page 54: ......
Page 61: ...Technical Data...
Page 62: ......
Page 65: ...65 EN US...
Page 66: ...66...
Page 67: ...67 EN US...