Before installation
Operating Per-
sonnel, Mainte-
nance Personnel
Setup Regula-
tions
The device has been tested according to protection class IP 21. This means:
-
Protection against solid foreign bodies larger than Ø 12.5 mm (0.49 inches)
-
Protection against dripping water
The device should not be set up and operated outdoors. The installed electrical compo-
nents should be protected against direct exposure to moisture.
Specifications for
the Compressed
Air Supply
To ensure the proper functioning of the cleaning device, fulfill the following specifications
for the compressed air supply:
-
Set up a compressed air supply using the pressure relief valve and compressed air
filter
-
Guarantee the compressed air quality in accordance with ISO 8573-1:2001, class 7 4
3, instrument air
-
Solid particle concentration
10 mg/m
3
-
Pressure concentration point vapor
+ 3°C
-
Oil concentration
1 mg/m
3
Grid Connection
The cleaning device is designed for the grid voltage listed on the rating plate. The fuse pro-
tection required for the grid lead may be found in the “Technical Data” section. If mains ca-
bles or mains plugs are not included with your version of the appliance, attach the
appropriate mains cable or mains plug in accordance with your country’s standards.
NOTE!
In all situations, the device must only ever be operated by one person. In
addition, make sure that there are no other people in the device’s operating area
while it is in operation.
NOTE!
In all situations, the device must only ever be maintained by one person.
In addition, make sure that there are no other people in the device’s operating
area while work on it is ongoing.
NOTE!
Install the device at a minimum distance of 1 m (40 inches) away from IT
equipment and control lines, as well as from the welding process.
NOTE!
Install the device with an all-round clearance of at least 0.5 m
(19.69 inches) to walls, neighboring devices, or other objects.
NOTE!
Set up the device in such a way that welding spatter cannot hit the clean-
ing device.
WARNING!
Danger of serious injury or damage to equipment from inadequately
dimensioned electrical installation. The grid lead and its fuse protection should be
designed to suit the device that is used. The technical data on the rating plate
should be followed.
CAUTION!
Danger of serious damage to property as a result of incorrect grid volt-
age. If the grid voltage is outside the tolerances specified in the technical data, do
not connect the device to the grid.
Summary of Contents for Cleaning Unit TC 2000
Page 2: ...2...
Page 4: ...4...
Page 15: ...General...
Page 16: ......
Page 24: ...24...
Page 25: ...Operating controls connections and mechanical components...
Page 26: ......
Page 34: ...34...
Page 35: ...Installation and Startup...
Page 36: ......
Page 43: ...43 EN US 4 Tightening torque 1 3 Nm 5 Tightening torque 0 5 Nm 6 4 1 5 1 2 3 4 6...
Page 52: ...52...
Page 53: ...Troubleshooting Maintenance and Disposal...
Page 54: ......
Page 61: ...Technical Data...
Page 62: ......
Page 65: ...65 EN US...
Page 66: ...66...
Page 67: ...67 EN US...