57
EN-US
Parting agent is not injected
‘Robacta Reamer’ parting agent container is full
Cause:
Injection quantity too low
Remedy:
Set injection quantity (injection time)
Cause:
Intake filter in ‘Robacta Reamer’ parting agent container dirty
Remedy:
Blow out the intake filter in the ‘Robacta Reamer’ parting agent container from
the inside out with compressed air using the intake hose
(see section
Clean the intake filter in the parting agent container
starting
on page
Cause:
Compressed air supply interrupted
Remedy:
Set up the compressed air supply
Cause:
Compressed air supply line defective or dirty
Remedy:
Clean compressed air supply line and replace if necessary
Cause:
Vacuum pump defective
Remedy:
Contact service team (vacuum pump needs replacing)
Cause:
Solenoid valve defective
Remedy:
Contact service team (solenoid valve needs replacing)
Parting agent is not injected
Cause:
‘Robacta Reamer’ parting agent container is empty
Remedy:
Fill with parting agent
Cause:
Interconnecting hosepack damaged
Remedy:
Inform service team
Pores in the weld seam
Cause:
Too much parting agent in the inside of the welding torch
Remedy:
Remove residues of parting agent by blowing out the inside of the welding
torch. Ensure supply of compressed air
Cause:
Too much parting agent in the inside of the welding torch
Remedy:
Reduce parting agent injection quantity (injection time)
Error is issued to robot. Overtemperature indication and fill level indication flash at
the same time; cleaning does not take place
Cause:
Quick Stop is active (HI - Quick Stop = LO or LO - Quick Stop = HI)
Remedy:
Deactivate Quick Stop (HI - Quick Stop = HI or LO - Quick Stop = LO)
Cause:
The cleaning device has detected an error
Remedy:
Disconnect the cleaning device from the grid and reconnect after approxi-
mately 1 minute
If this does not lead to any improvement, contact the service team and follow
the instructions in the next chapter
What to Do in the Event of an Error
page
Summary of Contents for Cleaning Unit TC 2000
Page 2: ...2...
Page 4: ...4...
Page 15: ...General...
Page 16: ......
Page 24: ...24...
Page 25: ...Operating controls connections and mechanical components...
Page 26: ......
Page 34: ...34...
Page 35: ...Installation and Startup...
Page 36: ......
Page 43: ...43 EN US 4 Tightening torque 1 3 Nm 5 Tightening torque 0 5 Nm 6 4 1 5 1 2 3 4 6...
Page 52: ...52...
Page 53: ...Troubleshooting Maintenance and Disposal...
Page 54: ......
Page 61: ...Technical Data...
Page 62: ......
Page 65: ...65 EN US...
Page 66: ...66...
Page 67: ...67 EN US...