56
Troubleshooting
Troubleshooting
Make a note of the serial number and configuration of the device, and provide the service
team with a detailed error description if:
-
Errors occur that are not covered in this document
-
The troubleshooting measures provided in this document are unsuccessful
Grid voltage indication does not light up
Grid lead connected
Cause:
Grid lead defective
Remedy:
Check grid lead
“Ready to clean” signal is not output to the robot control
Grid voltage indication lights up
Cause:
Quick Stop is active (HI - Quick Stop = LO or LO - Quick Stop = HI)
Remedy:
Deactivate Quick Stop (HI - Quick Stop = HI or LO - Quick Stop = LO)
Cause:
Supply to the standard I/O (X1) connection socket defective
Remedy:
Depending on the connection, check the assignment of inputs B and H or C
and H, as well as D or G
Cause:
Temperature sensor of cleaning coil defective
Remedy:
Contact service team – cleaning coil needs replacing
“Ready to clean” signal is not output to the robot control
Grid voltage indication lights up, overtemperature indication lights up
Cause:
Cleaning device has overheated
Remedy:
Allow cleaning device to cool down. As soon as the permissible operating
temperature has been reached, a new capacitor charging process will take
place. The cleaning device will then be ready to clean again
Summary of Contents for Cleaning Unit TC 2000
Page 2: ...2...
Page 4: ...4...
Page 15: ...General...
Page 16: ......
Page 24: ...24...
Page 25: ...Operating controls connections and mechanical components...
Page 26: ......
Page 34: ...34...
Page 35: ...Installation and Startup...
Page 36: ......
Page 43: ...43 EN US 4 Tightening torque 1 3 Nm 5 Tightening torque 0 5 Nm 6 4 1 5 1 2 3 4 6...
Page 52: ...52...
Page 53: ...Troubleshooting Maintenance and Disposal...
Page 54: ......
Page 61: ...Technical Data...
Page 62: ......
Page 65: ...65 EN US...
Page 66: ...66...
Page 67: ...67 EN US...