Plasma torch gets very hot
Plasma torch is under-dimensioned
Observe duty cycle and load limits
Coolant flow too low
Check coolant level, coolant flow rate, water contamination, etc. If
coolant pump blocked: use a screwdriver to turn on the shaft of the
coolant pump at the gland
Parameter C-C is set to "OFF".
In the Setup menu, set parameter C-C to "Aut" or "ON".
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy: