is automatically selected.
The main current I
main
can be adjusted immediately.
OFF
The last selected parameter remains selected during the plasma process.
The last selected parameter can be adjusted immediately. The main cur-
rent I
main
is not automatically selected.
COr
Gas correction
For entering a gas correction factor for the process gas
(only in conjunction with the "digital gas control" or "external gas regulat-
or" options)
Aut / 1.0 - 10.0
Factory setting: Aut
IMPORTANT!
More detailed explanations of the "COr" parameter can be
found in the "Digital Gas Control" Operating Instructions.
59
EN-US