IMPORTANT!
If the plasma power source is reset, all the personal set-
tings in the Setup menu are lost.
The jobs and parameter settings in the 2nd level Setup menu are not de-
leted when the plasma power source is reset.
2nd
2nd level Setup menu
Parameters in
the 2nd Level
Setup Menu
C-C
Cooling unit controls
Aut / ON / OFF
Factory setting: Aut
Aut ... The cooling unit cuts out 2 minutes after the end of the plasma
process
ON ... The cooling unit remains permanently ON
OFF ... The cooling unit remains permanently OFF
IMPORTANT!
If the cooling unit has the "Thermostat" option fitted, the
return-flow temperature of the coolant is constantly checked. If the re-
turn-flow temperature is less than 50 °C, the cooling unit cuts out auto-
matically.
C-t
Cooling time
Time from when the flow sensor is triggered until the "no | H2O" service
code is output
For example, if there are air bubbles in the cooling system, the cooling
unit will not cut out until the end of this preset time.
5 - 25 s
Factory setting: 10 s
IMPORTANT!
Every time the plasma power source is switched on, the
cooling unit carries out a test run for 180 seconds.
HFt
High frequency time
High frequency ignition: Time between HF impulses
0.01 - 0.4 s / EHF (starting with external ignition tool)
Factory setting: 0.01 s
IMPORTANT!
If there are problems with sensitive equipment in the im-
mediate vicinity, increase the HFt parameter up to as much as 0.4 s.
PrI
Delayed ignition for immediate high frequency start
OFF / 0.1 - 1 s
Factory setting; OFF
If a time is entered for the PrI parameter, arc ignition is delayed by this
amount of time: trigger signal - high frequency applied for the period of
time - arc ignition
r
Plasma system resistance
mOhm
57
EN-US
Summary of Contents for Acerios
Page 1: ...Operating instructions Acerios 42 0426 0326 EA 003 21032022 EN US Operating instructions...
Page 2: ......
Page 17: ...General information 17...
Page 18: ...18...
Page 21: ...Operating controls and connec tions 21...
Page 22: ...22...
Page 30: ...30...
Page 31: ...Installation and Startup 31...
Page 32: ...32...
Page 38: ...38...
Page 39: ...Plasma Surface Treatment 39...
Page 40: ...40...
Page 53: ...Setup Settings 53...
Page 54: ...54...
Page 68: ...68...
Page 69: ...Troubleshooting and Maintenance 69...
Page 70: ...70...
Page 79: ...Appendix 79...
Page 80: ...80...
Page 82: ...82...
Page 83: ...83 EN US...