dCY
Duty cycle
Relationship between pulse duration and base current duration at the set
pulse frequency
10 - 90%
Factory setting: 50%
I-G
Base current
0 - 100% (of main current I
main
)
Factory setting: 50%
tri
Operating mode selection
2t / 4t
2t = operating mode is 2-step mode
4t = operating mode is 4-step mode
t-S
Starting current time
OFF / 0.01 - 9.9 s
Factory setting: OFF
More information about the t-S parameter can be found on page
t-E
Final current time
OFF / 0.01 - 9.9 s
Factory setting: OFF
More information on the t-E parameter can be found on page
.
I-c
I
main
correction range for job retrieval
OFF / 1 - 100%
Factory setting: OFF
All the settings in the jobs are fixed and saved. Parameter I-c, however, al-
lows the main current I
main
to be subsequently corrected.
Example
Setup parameter I-c was set to 30%.
Main current I
main
can be reduced or increased by up to 30%.
IMPORTANT!
Each subsequent correction to the main current I
main
is re-
set when the plasma power source is switched off.
Exiting the Job
Correction Menu
1
Press the store button
67
EN-US
Summary of Contents for Acerios
Page 1: ...Operating instructions Acerios 42 0426 0326 EA 003 21032022 EN US Operating instructions...
Page 2: ......
Page 17: ...General information 17...
Page 18: ...18...
Page 21: ...Operating controls and connec tions 21...
Page 22: ...22...
Page 30: ...30...
Page 31: ...Installation and Startup 31...
Page 32: ...32...
Page 38: ...38...
Page 39: ...Plasma Surface Treatment 39...
Page 40: ...40...
Page 53: ...Setup Settings 53...
Page 54: ...54...
Page 68: ...68...
Page 69: ...Troubleshooting and Maintenance 69...
Page 70: ...70...
Page 79: ...Appendix 79...
Page 80: ...80...
Page 82: ...82...
Page 83: ...83 EN US...