9 - ENGLISH
4.5 ACTIVATION (FOR THE TECHNICIAN)
FRIGOMAT declines all and any liability for damage caused by failure to comply with the
following indications. This lack of compliance causes the warranty to terminate.
Connection of the machine to the water mains must be performed in compliance with
national regulations of the Country where the machine is installed.
To commission the machine, bring it to the place of use, checking what is requested for its
installation:
1. Electrical power supply 3 n earth (5 wires - 400V three-phase
mod.)
Electrical power supply 3 earth (4 wires - 220V three-phase mod.);
2. Cold water mains supply (13° - 20°C, only water mod.);
3. Condensation water drain (only water mod.)
.
x
Make sure the appliance is positioned on a solid, stable, flat and levelled surface.
x
Leave at least 10 cm from the panel on the right hand side and 30 cm from the panel on
the left hand side. For machines with water condensation, the distance between the
wall and the side panels must be 10 cm. In any case, the rear panel must be at just 5
cm from the wall or other obstacles.
x
Check the exact correspondence between the voltage and power of the mains
compared to the values carried on the data plate applied on the rear panel.
x
Connect the machine to the electrical power supply system. Install a omnipolar master
switch upstream the appliance with minimum contact opening of 3 mm of adequate
power, with a fuse and circuit breaker protective system. Use an approved interlocking
plug to allow only the open circuit to connect and disconnect.
x
The cable must be well laid, without being rolled-up or overlapped. It must not be
exposed to blows or tampering. It must not be in the vicinity of liquids or water and heat
sources. It must not be damaged in any way. If so, before connecting the machine to
the mains, have it replaced by qualified personnel with another having a 5G4 H07RN-F
(400 V version) or 5G6 H07RN-F (220 V/3 version).
x
For safety purposes, make sure the earthing system to which the machine plug is
connected is compliant with standards and perfectly efficient.
Summary of Contents for KISS 3 POWER Series
Page 47: ...ENGLISH 46 ...