ENGLISH - 6
3. GENERAL SAFETY STANDARDS
Strictly comply with the general Safety and Accident-prevention Standards listed hereafter:
- Use of the machine is reserved for personnel in good health, responsible and
appropriately trained regarding allowed use and risks present.
- Use of the machine is reserved for operators who have read, understood and taken
in all that is included in this manual.
- It is forbidden to remove or tamper with the safety systems installed on the
machine.
- While the appliance is operating, it is mandatory to check that dangerous situations
for persons do not occur. Should these conditions transpire, stop the appliance
immediately.
- When you have finished working with the machine, it is mandatory to cut power by
acting on the master switch.
- When unusual noise or anomalous functioning is perceived, it is mandatory to
immediately stop operations in progress and to search for the cause of these
irregularities. If in doubt, avoid improper operations by contacting the
manufacturer's after-sales service.
- Any tampering or modification of the machine automatically entails the immediate
termination of the warranty and relieves the manufacturer of all and any liability for
direct or indirect damage caused.
- It is mandatory to check that the place where the machine is installed is ventilated
and correctly illuminated. The surface where the appliance is installed must be
solid, flat and levelled.
- During loading, unloading and handling operations, it is mandatory to use
equipment with a capacity adequate for the mass (weight) of the machine, using
hoisting devices and accessories with features and state of use suitable for the
purpose.
- Use only FRIGOMAT original spare parts when performing maintenance. The
manufacturer will not be held liable for damage caused by use of non-original spare
parts. Use of non-original spare parts entails automatic termination of the warranty.
- It is mandatory to position the machine far away from equipment which emits
electromagnetic radiation which could cause the circuit boards to malfunction.
- If fire-prevention equipment is necessary use types which are compatible with the
presence of voltage on board.
- It is forbidden to wear long and loose apparel, ties, jewellery, scarves or similar
clothing which could get caught in the moving parts of the machine.
- Hair must be tied back and shirt-sleeves tight.
Summary of Contents for AGG.2014 Series
Page 1: ...USE AND MAINTENANCE MANUAL Series AGG 2014 C 136 04 C137 04 C138 04 ...
Page 61: ...ENGLISH 60 ...
Page 63: ...APPENDICI 2 9 2 Refrigerant circuit diagram ...
Page 66: ...5 APPENDICI C136 37 38 s04 Tav 1 ...
Page 68: ...7 APPENDICI C136 37 38 s04 OPTIONAL Tav 2 ...
Page 70: ...9 APPENDICI C136 37 38 s04 Tav 3 ...
Page 72: ...11 APPENDICI C136 37 38 s04 Tav 4 ...
Page 74: ...13 APPENDICI C136 37 38 s04 400 50 3 Tav 5 ...
Page 76: ...15 APPENDICI C136 37 38 s04 220 60 3 Tav 6 ...
Page 78: ...17 APPENDICI C136 37 38 s04 Tav 7 ...
Page 80: ...19 APPENDICI C136 37 38 s04 Tav 8 ...
Page 82: ...21 APPENDICI C138 s04 Tav 9 ...
Page 84: ...23 APPENDICI C136 C137 s04 Tav 10 ...
Page 86: ...25 APPENDICI C136 37 38 s04 Tav 11 ...
Page 88: ...27 APPENDICI C136 37 38 s04 Tav 12 ...
Page 90: ...29 APPENDICI C136 37 38 s04 400 50 3 Tav 13 ...
Page 92: ...31 APPENDICI C136 37 38 s04 220 60 3 Tav 14 ...
Page 94: ...NOTE NOTES NOTES BEMERKUNG NOTA ...
Page 95: ......