ELECTRICAL TESTS AND SERVICE PROCEDURES
Page 47
Service Manual TDR8 P Gas form 9124023 rev. 01/2022
GAS CONSUMPTION
With a flow meter you can measure the gas
consumption/flow. See table on page 38. To
get an accurat consumption you have to do a
measurement of 3-5 minutes. During this pe-
riod the rotisserie the rotisserie may not turn
off.
MAINTENANCE GAS PROCESSING
The customer should have the gas rotisserie periodically checked by a skilled technician ac-
cording local, state or national regulations.
First remove the right side panel according procedure in removal and replacement of parts.
Check for gas leaks and/or bad connections of the gas supply inside and outside.
• Check the gas burner and the ignition/ionisation set.
• Check the adjustment of the ignition/ionistation set.
• Check all gaskets.
• Check the inlet pressure and re-adjust if necessary. For the correct value, see table on
page 10.
• Check the consumption of the gas, see table on page 38.
• Measure the exhaust gas with a flue gas analyzer, see page 45.
• Check the electrical supply.
• Make a test run.