9
CB3
14
CB3
15
CB3
13
8
CB3
8
CB3
6
CB3
12
PE
CB3
14
CB3
12
CB3
14
CB3
12
CB3
16
16
16
17
17
CB3
CB3
CB3
CB3
1
2
2
1
TH
21
24
K1
11
14
K2
Rel
. 3
Rel
. 1
Rel
. 4
Rel
. 12
J6-2
J6-1
J2-3
Rel
. 2
PD
-42TE
J2-1
J1-5 N
L
PE
J1-1
J6-3
J1-3
J6-4
J2-5
J2-2
Rel
.13
J6-5
J2-6
J2-4
J8-1
J8-2
J13-1
J13-2
U1
CB3
A2
K2
A1
GAS BLOWER
7
CB3
1
CB3
CB3
5
CB3
6
ROTOR
CB3
7
A2
K1
A1
GAS BURNER CONTROL
6
CB3
1
CB4
6
CB4
5
CB4
3
CB4
2
CB4
TRAFO 230/12V
7
3
CB3
CB3
7
8
CB3
CB3
2
CB3
8
4
CB3
BLOWERS
CB3
CB3
6
FAN (OPTION)
CONTROLLED BY TOP UNIT
LOCATED IN BOTTOM UNIT
van Susan
te A
dmin
23.03.2020
9290855
In P
rog
ress
3180
Cir
cuit Diag
ram
TDR G
as 230V v2
9290855
A3
1:1
mm
C
A
~230V
1
2
5
4
BU
WH
BK
GY
M4
CONTR
OL
L1
1
9
16
8
M4-5
6
1
5
10
4
1
3
6
BU
OR
GY
BK
YE
BN
WH
BK
OR
GY
BN
WH
X1
X3
M4-1
M4-2
M4-4
M4-PWR(115V)
HIGH LIMIT
RESE
T
Ionisation Pin
Ignition
F1
F2
10 A
mp
10 A
mp
L1 BN
4
3
24
25
L2 PE
2
33
L1
30
27
ERR
OR
H1
S1
X2
YE
OPTION DISPLA
Y
CB5 OPTION
OPTION
HMI
HMI
DISPLA
Y
GY = GRE
Y
BU = BL
UE
BK = BLA
CK
YE
= Y
ELL
OW
BN = BR
OWN
WH
= WHITE
OR = OR
ANGE
RD = RED
GAS BURNER C
ONTR
OL
S4965-2166/3166
CONTR
OL
1 - 24DC
2 - T
ACHO
4 - PWM 5 - GND
GAS BL
OWER R
G128
F1 1AT
250V
U1
J6-6
32
15
16
DOOR SWITCHES
R1 PT1000
OVEN TEMP.
29
28
WH(
A)
M1
BN
9
C1
2.5 uF
WH
7
11
94
90
91
92
93
6
BU
RD
GY
18
19
3x12V
17
3x12V
14
WH
WH
10
YE
T1
1.5 uF
C2
BN
M2
BK
BK
M3
BN
C3
1.5 uF
BU
BU
12
48
M5
47
AR
T. NUMBER
REM
ARK
RE
V. D
ATE
RE
VISION
MA
TERIAL AR
T. NUMBER
MA
TERIAL
Tol
. pr
inciple
Gen. t
oler
anc
e
Sur
fac
e tr
ea
tmen
t
Geom. t
oler
anc
e
DR
AWN
APPR
OVED
DAT
E
DR
AWING NUMBER
PR
OJEC
T
STA
TUS
UNIT
SC
ALE
REM
ARKS
DESCRIPTION
SIZE
RE
V.
30
TB2/GY
30
60
61
Page 80
Service Manual TDR8 P Gas form 9124023 rev. 01/2022
ELECTRICAL DIAGRAMS
CIRCUIT DIAGRAM TDR 8 P GAS FROM SERIAL NUMBER 100097993