ELECTRICAL TESTS AND SERVICE PROCEDURES
Page 42
Service Manual TDR8 P Gas form 9124023 rev. 01/2022
ERROR CODES ON DISPLAY
Error 11:
Full contact between wires of PT sensor. Temp. indication on display doesn’t go up.
Error 33:
No connection between wires of PT sensor. Temp. indication on display 317°C/602°F.
Error 55:
Heating defect. Temperature rise in °C/minute of the PT sensor during cooking of
the products is under the minimum value as indicated in parameter “Temp. grad.” See also
the parameterlist on page 57 and explanation on page 52.
Error 77:
If the expected heat number is more than 20% lower than the stored heat number
in the cooking program. This error does not result in a complete shut down of the rotisserie,
but is stored in the fault messages in the service menu.
Error 88:
If the expected heat number is more than 20% higher than the stored heat number
in the cooking program. This error does not result in a complete shut down of the rotisserie,
but is stored in the fault messages in the service menu.
App. Error:
- Parameter file cannot be openend when switching the TDR on.
- Failure during loading of parameters or programs.
- Communication failure keypad and CPU.
For explanation and solving of the errors see general troubleshooting list on page 58.
CONTROL LOCATION
CHICKEN
85 1 2 3 7
Display
On / Off
Rotor
OK
Forward
List
Undo
Back
Key
Function
On / Off
Switching the unit On / Off
Undo
Go back to previous menu
List
Recipe / programming modus
Forward
One step ahead in setting
Rotor
Switching the rotor on
OK
Acknowledge a function or change
Back
One step back in setting