5-9
Communication
address
Fcode
485
number
Link number
Function name
Setting range
h40
428h
( h) RS485
(Protocol)
0 to 1 to 2
0 : FUJI inverter protocol
1 : SX bus (FUJI private link) protocol
2 : Modbus RTU protocol
Please set 1 (SX bus protocol) when you use the PC
loader of the VG7 exclusive use.
h41
429h 209( D1 h) Torque
reference
selection
0 to 5
0 : Internal ASR output
1 : AI terminal input (T-REF)
2 : DIA card input
3 : DIB card input
4 : Link input
5 : PID
h42
42Ah 210( D2 h) Torque current
reference
selection
0 to 4
0 : Internal ASR output
1 : AI terminal input (IT-REF)
2 : DIA card input
3 : DIB card input
4 : Link input
h43
42Bh 211( D3 h) Magnetic flux
reference
selection
0 to 3
0 : Internal calculation value
1 : AI terminal input (MF-REF)
2 : Function setting value (H44)
3 : Link input
h44
42Ch 212( D4 h) Magnetic flux
reference
value
10 to 100 %
h46
42Eh 215( D7 h) Observer
(Mode select)
0 to 2
0 : Inactive
1 : Active (load disturbance observer)
2 : Active (oscillation suppressing observer)
h47
42Fh 216( D8 h) (P-gain 1)(M1) 0.00 to 1.00 (times)
h48
430h
( h) (P-gain 2)(M2) 0.00 to 1.00 (times)
h49
431h 217( D9 h) (I-gain 1)(M1)
0.005 to 0.100 to 1.000 s
h50
432h
( h) (I-gain 2)(M2)
0.005 to 0.100 to 1.000 s
h51
433h 218( DA h) Load inertia
M1
0.01 to 50.000 (kg.m
2
)
(Target ROM No. H1/20064 or later)
h52
434h
( h) Load inertia
M2
0.01 to 50.000 (kg.m
2
)
(Target ROM No. H1/20064 or later)
h53
435h 213( D5 h) Line speed
feedback
selection
0 to 3
0 : Line speed disabled
1 : Line speed (analog input) (AI-LINE)
2 : Line speed (digital input) (PG(LD))
3 : High level selected signal
h55
437h
( h) Zero speed
control (Gain)
0 to 5 to 100 (times)
h56
438h
( h) Completion
range
0 to 100 (pulse)
h57
439h
( h) OU alarm
prevention
0 to 1
0 : Inactive
1 : Active
h58
43Ah
( h) OC alarm
prevention
0 to 1
0 : Inactive
1 : Active
h60
43Ch
( h) Load adaptive
control
function 1
0 to 3
0 : Inactive
1 : Method 1
2 : Method 2
3 : Method 3
h61
43Dh
( h) Load adaptive
control
function 2
0 to 1
0 : Winding up on forward rotation
1 : Winding down on forward rotation
h62
43Eh
( h) Winding up
speed
0.0 to 999.9 m/min
h63
43Fh
( h) Counter weight 0.00 to 600.00 (t)
h64
440h
( h) Safety
coefficient (for
rated torque)
0.50 to 1.00 to 1.20
h65
441h
( h) Machine
efficiency
0.500 to 1.000
h66
442h
( h) Rated loading
0.00 to 600.00 (t)
h68
444h
( h) Alarm data
delete
0 to 1
If these tuning are finished, this data code returns to 0.
h70
446h
( h) Reserved 1
0 to 9999
0 : Standard
1 : Lift
2 to 9999 : Undecided
Communication
address
Fcode
485
number
Link number
Function name
Setting range
h71
447h
( h) Reserved 2
0 to 6
It is not necessary to set usually.
If these tuning are finished, this data code returns to 0.
0 : Inactive
1 : ACR system tuning
2 : Voltage gain tuning (execution without connecting
motor)
3 : Voltage sensor offset tuning
4 : Current sensor balance tuning
5 : Magnet pole position tuning (for SM driving)
6 : Shunt resistor gain tuning
h72
448h
( h) Reserved 3
0 to 9999
0 : standard
1 to 9999 : Undecided
h73
449h
( h) Reserved 4
0 to 9999
0 : standard
1 to 9999 : Undecided
A: Alternative Motor Parameters
Communication
address
Fcode
485
number
Link number
Function name
Setting range
a01
501h
( h) M2-Control
method
0 to 1
M2 is an induction motor only for the vector control.
0 : Vector control with PG
1 : Vector control without PG
a02
502h
( h) M2-Rated
capacity
0.00 to 500.00kW at F60=0
0.00 to 600.00HP at F60=1
a03
503h
( h) M2-Rated
current
0.01 to 99.99A
100.0 to 999.9A
1000 to 2000A
a04
504h
( h) M2-Rated
voltage
80 to 999 V
a05
505h
( h) M2-Rated
speed
50 to 1500 to 24000 r/min
a06
506h
( h) M2-Maximum
speed
50 to 1500 to 24000 r/min
a07
507h
( h) M2-Poles
2 to 4 to 12 (poles)
a08
508h
( h) M2-%R1
0.00 to 30.00 %
a09
509h
( h) M2-%X
0.00 to 50.00 %
a10
50Ah
( h) M2-Exciting
current
0.01 to 99.99A
100.0 to 999.9A
1000 to 2000A
a11
50Bh
( h) M2-Torque
current
0.01 to 99.99A
100.0 to 999.9A
1000 to 2000A
a12
50Ch
( h) M2-Slip
(Driving)
0.001 to 10.000 Hz
a13
50Dh
( h) M2-Slip
(Braking)
0.001 to 10.000 Hz
a14
50Eh
( h) M2-Iron loss
coefficient 1
0.00 to 10.00 %
a15
50Fh
( h) M2-Iron loss
coefficient 2
0.00 to 10.00 %
a16
510h
( h) M2-Iron loss
coefficient 3
0.00 to 10.00 %
a17
511h
( h) M2-Magnetic
saturation
coefficient 1
0.0 to 100.0 %
a18
512h
( h) M2-Magnetic
saturation
coefficient 2
0.0 to 100.0 %
a19
513h
( h) M2-Magnetic
saturation
coefficient 3
0.0 to 100.0 %
a20
514h
( h) M2-Magnetic
saturation
coefficient 4
0.0 to 100.0 %
a21
515h
( h) M2-Magnetic
saturation
coefficient 5
0.0 to 100.0 %
a22
516h
( h) M2-Secondary
time constant
0.001 to 9.999 s
a23
517h
( h) M2-Induced
voltage
coefficient
0 to 999 V
a24
518h
( h) M2-R2
correction
coefficient 1
0.000 to 5.000
a25
519h
( h) M2-R2
correction
coefficient 2
0.000 to 5.000
Underline indicates a factory setting.
Items without underline have different factory settings according to capacity.
You can change the setting of a function indicated by during operation.
You should stop operation to change the setting of other functions.
Summary of Contents for 5000VG7S Series
Page 7: ...0 6 Warning Label Position for Inside the Inverter...
Page 23: ...2 5 Basic Wiring Diagram Figure 2 3 1 Basic Wiring Diagram...
Page 36: ...2 18 l Control circuit terminals Control circuit terminals Screw size M3...
Page 94: ...9 4 FS5941 40 47 Figure 9 1 FS5941 60 52 FS5941 86 52 Figure 9 2...
Page 96: ...9 6 RF3280 F11 RF3400 F11 Figure 9 5 RF3880 F11 Figure 9 6 6 6 Figure 9 7 F200160...