5-3
Communication
address
Fcode
485
number
Link number
Function name
Setting range
f53
35h
( h) LED monitor
coefficient
(Display
coefficient B)
-999.00 to 1.00 to 999.00
The conversion coefficient to decide the reference value
of the PID adjustment machine and the display value
(amount of the process) of the amount of feedback is
set by using display coefficient A and B.
Display coefficient A ; Maximum value
Display coefficient B ; Minimum value
Display value = (Reference value or feedback value) *
(Display coefficient A - B) + B
f54
36h
( h) LED display
filter
0.0 to 0.2 to 5.0 s
Filter to prevent LED from flickering by change of the
display data.
The filter is effective in all the data selected with F55.
f55
37h
( h) LED
(Selection)
0 to 28
0 : Detected speed 1 or reference speed (r/min)
(depending on F56 while motor is stopped)
1 : Speed reference value 4 (ASR input) (r/min)
2 : Output frequency after slip compensation (Hz)
3 : Torque current reference (%)
4 : Torque reference value (%)
5 : Torque (calculated value) (%)
6 : Inverter input power (kW or HP) (depending on F60)
7 : Output current (A)
8 : Output voltage (V)
9 : DC link circuit voltage (V)
10 : Magnetic flux reference (%)
11 : Magnetic flux (calculated value) (%)
12 : Motor temperature (
℃
) ("---" is displayed when NTC
thermistor unused.)
13 : Load shaft speed (r/min) (depending on F56)
14 : Line speed (m/min) (depending on F56)
15 : Ai adjusted value (12) (%)
16 : Ai adjusted value (Ai1) (%)
17 : Ai adjusted value (Ai2) (%)
18 : Ai adjusted value (Ai3) (%)
19 : Ai adjusted value (Ai4) (%)
The following data becomes non-display by the mode
on the option.
20 : PID reference (%) (Display at the PID mode)
21 : PID feedback value (%) (Display at the PID mode)
22 : PID output value (%) (Display at the PID mode)
23 : Option monitor 1 (HEX) (Displayed with use of
option)
24 : Option monitor 2 (HEX) (Displayed with use of
option)
25 : Option monitor 3 (DEC) (Displayed with use of
option)
26 : Option monitor 4 (DEC) (Displayed with use of
option)
27 : Option monitor 5 (DEC) (Displayed with use of
option)
28 : Option monitor 6 (DEC) (Displayed with use of
option)
f56
38h
( h) LED (Display
at stop mode)
0 to 1
Change of the display on F55 when the motor is
stopping.
The corresponding data is speed (0), load shaft rotation
speed (13), and line speed (14).
0 : Speed reference (r/min)
1 : Speed feedback (r/min)
f57
39h
( h) LCD
(Selection)
0 to 1
Change of operation mode display on Keypad panel
0 : Operation guide (State of operation, Direction of
rotation)
1 : Bar graph monitor (Speed, Current, Torque)
f58
3Ah
( h) LCD
(Language)
0 to 7
0 : Japanese
1 : English
2 : German
3 : French
4 : Spanish
5 : Italian
6 : Chinese
7 : Korean
f59
3Bh
( h) LCD
(Contrast)
0 to 5 to 10
0 (Soft) to 10 (Hard)
f60
3Ch
( h) Output unit
selection (kW
or HP)
0 to 1
The unit of inverter power consumption and motor
(M1,2,3) of the function setting is defined.
0 : kW
1 : HP
f61
3Dh 107( 6B h) ASR1 (P-gain) 0.1 to 10.0 to200.0 (times)
Communication
address
Fcode
485
number
Link number
Function name
Setting range
f62
3Eh 108( 6C h) ASR1 (I-gain)
0.010 to 0.200 to1.000 s
P control when setting 1.000
f63
3Fh 109( 6D h) ASR1 (Feed
forward gain)
0.000 to 9.999 s
f64
40h 110( 6E h) ASR1 (Input
filter)
0.000 to 0.040 to 5.000 s
f65
41h 111( 6F h) ASR1
(Detection
filter)
0.000 to 0.005 to 0.100 s
f66
42h 112( 70 h) ASR1 (Output
filter)
0.000 to 0.002 to 0.100 s
f67
43h 113( 71 h) S-curve
(Acc start side)
0 to 50 %
f68
44h 114( 72 h) S-curve (Acc
end side)
0 to 50 %
f69
45h 115( 73 h) S-curve (Dec
start side)
0 to 50 %
f70
46h 116( 74 h) S-curve (Dec
end side)
0 to 50 %
f73
49h
( h) Magnetic flux
at light load
10 to 100 %
f74
4Ah 117( 75 h) Pre-exiting
time
0.0 to 10.0 s
f75
4Bh 118( 76 h) Pre-excitation
initial Level
100 to 400 %
f76
4Ch
( h) Speed limiter
(Mode select)
0 to 3
0 : Limiting level 1 for forward rotation, and limiting level
2 for reverse rotation
1 : Limiting level 1 for both side rotation
2 : Limiting level 1 for upper limit, and limiting level 2 for
lower limit
3 : Forword (Level 1) and reverse (Level 2). Add the [12]
input as a bias.
f77
4Dh
79( 4F h) Speed limiting
(Level 1)
-110.0 to 100.0 to 110.0 %
f78
4Eh 254( FE h) Speed limiting
(Level 2)
-110.0 to 100.0 to 110.0 %
f79
4Fh 119( 77 h) Motor
selection (M1,
M2, M3)
0 to 2
An effective motor (M1, 2 or 3) is selected by the
function or terminal.
0 : M1 select
The signal input by the terminal is given to priority.
M1 select ; (MCH2,MCH3)=(OFF,OFF) (If there is
no allocation)
M2 select ; (MCH2,MCH3)=(ON ,OFF)(ON,ON)
1 : M2 select (x function inactive)
2 : M3 select (x function inactive)
f80
50h
( h) Current rating
switching
0 to 2
0 : CT (Overload current 150%)
1 : VT (Overload current 110%)
2 : HT (Overload torque 200/170%)
Underline indicates a factory setting.
Items without underline have different factory settings according to capacity.
You can change the setting of a function indicated by during operation.
You should stop operation to change the setting of other functions.
Summary of Contents for 5000VG7S Series
Page 7: ...0 6 Warning Label Position for Inside the Inverter...
Page 23: ...2 5 Basic Wiring Diagram Figure 2 3 1 Basic Wiring Diagram...
Page 36: ...2 18 l Control circuit terminals Control circuit terminals Screw size M3...
Page 94: ...9 4 FS5941 40 47 Figure 9 1 FS5941 60 52 FS5941 86 52 Figure 9 2...
Page 96: ...9 6 RF3280 F11 RF3400 F11 Figure 9 5 RF3880 F11 Figure 9 6 6 6 Figure 9 7 F200160...