25
| OPERATION MANUAL
CONNECTOR: CAN (CANBUS)
TYPE: MOLEX MICROFIT RA 4 PIN
2
1
3
4
1. GND
2. +V Ba
3. CAN H
4. CAN L
CONNECTOR: CAM (CAMERA)
TYPE: MOLEX MICROFIT RA 8 PIN
1
2
3
4
5 6
7 8
1. GND
2. +5V
3. RxD
4. TxD
5. LANC Power
6. LANC Signal
7. GPO/UART TX
8. GPI/UART RX
CONNECTOR: 12-14V CAM (CAMERA POWER)
TYPE: FEMALE D-TAP
+
-
1. (+) 14V DTAP V+
2. (-) 14V DTAP GND